Biomechanical analysis of the door-shaped titanium plate in single-level anterior cervical discectomy and fusion

被引:0
|
作者
Li, Senli [1 ]
Yan, Peng [1 ]
Fan, Yanwei [1 ]
Wang, Ruibo [1 ]
Zhang, Changjiang [1 ]
机构
[1] Zhengzhou Univ, Dept Orthoped 2, Affiliated Hosp 5, Zhengzhou 450052, Peoples R China
关键词
Anterior cervical discectomy and fusion; Door-shaped titanium plate; Range of motion; Neutral zone; Biomechanical study; ADJACENT-SEGMENT PATHOLOGY; FOLLOW-UP; INTERBODY FUSION; SPONDYLOTIC MYELOPATHY; ILIAC-GRAFT; SPINE; CAGE; OSSIFICATION; DISC; DYSPHAGIA;
D O I
10.1186/s13018-023-04474-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Analyse and discuss the immediate stability of the cervical spine after anterior cervical discectomy and fusion using a door-shaped titanium plate and compare it with the traditional titanium plate, to provide biomechanical evidence for the rationality and effectiveness of the door-shaped titanium plate in clinical applications.Methods Ten adult goat C4/5 vertebral bodies were obtained, and models were prepared using denture base resin. Biomechanical experiments were performed on the specimens before internal fixation. MTS was used to conduct non-destructive biomechanical loading tests in six directions, including flexion, extension, left-right bending, and left-right torsion, recording the range of motion (ROM) and neutral zone (NZ) of each specimen. The specimens were then randomly divided into two groups: the study group was fixed with a door-shaped titanium plate, and the control group was fixed with a traditional titanium plate. ROM and NZ in each direction were measured again. After measurements, both groups were subjected to 0.5 Hz torsion loading with a torque of 2 N m for a total of 3000 cycles, followed by measuring ROM and NZ in six directions once more.Results Compared to before fixation, ROM and NZ in both groups significantly decreased in all six directions after fixation, with statistical significance (P < 0.05); after fixation, the study group showed slightly lower values for various mechanical reference parameters compared to the control group, with no statistical significance (P > 0.05); after 3000 torsional loads, both internal fixation groups showed increased ROM and NZ compared to after fixation but to a lower extent, and no screw or titanium plate loosening was observed. Compared to before fixation, the differences were still statistically significant (P < 0.05), with the study group having slightly lower ROM and NZ values in all directions compared to the control group, with no statistical significance (P > 0.05).Conclusion The door-shaped titanium plate exhibits mechanical properties similar to the traditional titanium plate in all directions, and its smaller size and simpler surgical operation can be used for anterior cervical endoscopic surgery, reducing surgical trauma. It is clinically feasible and deserves further research and promotion.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Biomechanical analysis of the door-shaped titanium plate in single-level anterior cervical discectomy and fusion
    Senli Li
    Peng Yan
    Yanwei Fan
    Ruibo Wang
    Changjiang Zhang
    Journal of Orthopaedic Surgery and Research, 18
  • [2] Adjacent-Level Ossification Development in Single-Level Standalone Anterior Cervical Discectomy and Fusion Versus Anterior Cervical Discectomy and Fusion With Plate
    Huang, Christopher
    Mobbs, Ralph
    Selby, Michael
    Phan, Kevin
    Rao, Prashanth
    GLOBAL SPINE JOURNAL, 2021, 11 (03) : 292 - 298
  • [3] The effect of cervical plating on single-level anterior cervical discectomy and fusion
    Wang, JC
    McDonough, PW
    Endow, K
    Kanim, LEA
    Delamarter, RB
    JOURNAL OF SPINAL DISORDERS, 1999, 12 (06): : 467 - 471
  • [4] Clinical Outcomes of Single-Level Anterior Cervical Discectomy and Fusion
    Niedermeier, Steven R.
    Virk, Sohrab S.
    Khan, Safdar N.
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2018, 12 (02): : 149 - 153
  • [5] Cost-effectiveness analysis: comparing single-level cervical disc replacement and single-level anterior cervical discectomy and fusion
    Qureshi, Sheeraz A.
    McAnany, Steven
    Goz, Vadim
    Koehler, Steven M.
    Hecht, Andrew C.
    JOURNAL OF NEUROSURGERY-SPINE, 2013, 19 (05) : 546 - 554
  • [6] Surgeon Specialty Differences in Single-Level Anterior Cervical Discectomy and Fusion
    Minhas, Shobhit V.
    Chow, Ian
    Patel, Alpesh A.
    Kim, John Y. S.
    SPINE, 2014, 39 (20) : 1648 - 1655
  • [7] Biomechanical analysis of a single-level customized cage screw fixation for anterior cervical discectomy and fusion in the cervical spine: an in-silico study
    Kumar, Ram
    Kumar, Amit
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (04):
  • [8] Biomechanical performance of the novel assembled uncovertebral joint fusion cage in single-level anterior cervical discectomy and fusion: A finite element analysis
    Zhang, Xiang
    Yang, Yi
    Shen, Yi-Wei
    Zhang, Ke-Rui
    Ma, Li-Tai
    Ding, Chen
    Wang, Bei-Yu
    Meng, Yang
    Liu, Hao
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [9] Cost-effectiveness of single-level anterior cervical discectomy and fusion for cervical spondylosis
    Angevine, PD
    Zivin, JG
    McCormick, PC
    SPINE, 2005, 30 (17) : 1989 - 1997
  • [10] Outcomes of single-level cervical disc arthroplasty versus anterior cervical discectomy and fusion
    Tracey, Robert W.
    Kang, Daniel G.
    Cody, John P.
    Wagner, Scott C.
    Rosner, Michael K.
    Lehman, Ronald A., Jr.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (11) : 1905 - 1908