Evaluation of the Marginal Fit of Computer-Aided Design (CAD) and Computer-Aided Manufacturing (CAM) Zirconia Bridges Fabricated With Different Firing Cycles of Veneering Porcelain: An In Vitro Study

被引:0
|
作者
Chokr, Hawraa [1 ]
Alshaarani, Fendi [1 ]
Husein, Hassan A. [1 ]
机构
[1] Damascus Univ, Fac Dent Med, Dept Fixed Prosthodont, Damascus, Syria
关键词
computer-aided design; computer-assisted manufacture (cad; cam); marginal fit; firing cycles; zrconia; cad cam; veneering porcelain; SYSTEMS; CROWNS;
D O I
10.7759/cureus.34842
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Zirconia provides adequate mechanical strength to be used as a framework for all ceramic prostheses. Such prostheses must be covered with suitable porcelain to obtain good aesthetic results.The aim To study the effect of the firing cycle numbers of veneering ceramics (one cycle, two cycles, and three cycles) on the marginal fit of computer-aided design (CAD) and computer-aided manufacturing (CAM) zirconia bridges.Materials and methods The sample consisted of 30 full ceramic zirconia bridges, designed by CAD/CAM on a metal bridge model that was designed for this purpose. The sample was divided into three groups (N = 10); group A underwent a single firing cycle, group B underwent two cycles, and group C underwent three cycles. The copper model of the bridge was prepared to be a three-unit bridge, and the impressions of the metal models were taken to make zirconia cores. After that, the veneering ceramic layer and the micro-marginal gap were measured (in microns) on both the buccal and lingual surfaces of each bridge in the sample using the replica technique. A one-way ANOVA test was used to detect statistically significant differences between the groups.Results There were no significant differences between the studied groups in binary comparison; however, the arithmetic mean values of the marginal gap in group C were greater than all the studied groups.Conclusion Within the limitations of the current work, we found that increasing the number of firing cycles of zirconia cores affects the marginal fit; thus, it is recommended to follow the two firing cycle protocol for better adaptation of the CAD/CAM zirconia bridges.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Marginal fit of three different nanocomposite inlays fabricated with computer-aided design/computer-aided manufacturing (CAD/CAM) technology: a comparative study
    Choi, Hyunsuk
    Jo, Jae -Young
    Hong, Min-Ho
    JOURNAL OF YEUNGNAM MEDICAL SCIENCE, 2024, 41 (02): : 80 - 85
  • [2] A Comparative Study of the Marginal Fit of Endocrowns Fabricated From Three Different Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) Ceramic Materials: An In Vitro Study
    Attar, Esraa
    Alshali, Shatha
    Abuhaimed, Tariq
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (06)
  • [3] Evaluation of marginal accuracy of polyetheretherketone and zirconia copings fabricated using computer-aided design/computer-aided manufacturing technique: An in vitro study
    Jangade, Manish
    Sharma, Ranu
    Sudharson, Nishanth A.
    Jain, Raj
    Sahu, Shailendra Kumar
    Dani, Anurag
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2025, 25 (01): : 95 - 101
  • [4] Marginal Fit Evaluation of Zirconia Substructure Computer-Aided Design and Manufacturing (CAD/CAM) by Scanning Electron Microscope
    Abu-Ras, Kian
    Dolev, Eran
    Biadsee, Ameer
    Ormianer, Zeev
    APPLIED SCIENCES-BASEL, 2023, 13 (19):
  • [5] Marginal fit of three different nanocomposite inlays fabricated with computer-aided design/computer-aided manufacturing (CAD/CAM) technology: a comparative study (vol 41, pg 80, 2024)
    Choi, Hyunsuk
    Jo, Jae-Young
    Hong, Min-Ho
    JOURNAL OF YEUNGNAM MEDICAL SCIENCE, 2024, 41 (03):
  • [6] A comparative evaluation of marginal fit and microleakage of computer-aided design/computer-aided manufacturing-milled zirconia and prefabricated posterior occlusal veneers: An in vitro study
    Bhati, Vasundhra
    Kapoor, Vikram
    Pasricha, Neeta
    Raman, Shrimant
    Sirana, Pallavi
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2024, 24 (03): : 233 - 239
  • [7] COMPUTER-AIDED-DESIGN AND COMPUTER-AIDED MANUFACTURING (CAD CAM) IN PROSTHETICS
    TOPPER, AK
    FERNIE, GR
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (256) : 39 - 43
  • [8] Marginal accuracy of computer-aided design- and computer-aided manufacturing-fabricated full-arch zirconia restoration
    Juntavee, Niwut
    Sirisathit, Issarawas
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2018, 10 : 9 - 17
  • [9] Maxillary sinus augmentation using computer-aided design/computer-aided manufacturing (CAD/CAM) technology
    Mangano, F.
    Zecca, P.
    Pozzi-Taubert, S.
    Macchi, A.
    Ricci, M.
    Luongo, G.
    Mangano, C.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2013, 9 (03): : 331 - 338
  • [10] Genioplasty using a simple CAD/CAM (computer-aided design and computer-aided manufacturing) surgical guide
    Lim S.-H.
    Kim M.-K.
    Kang S.-H.
    Maxillofacial Plastic and Reconstructive Surgery, 37 (1)