Is the femoral intramedullary alignment already actual in total knee arthroplasty?

被引:2
|
作者
Tecame, Andrea [1 ]
Gambineri, Andrea [1 ]
Za, Pierangelo [2 ]
Adravanti, Paolo [1 ]
机构
[1] Citta Parma Clin, Dept Orthopaed & Trauma Surg, Piazzale Athos Maestri 5, Parma, Italy
[2] Campus Biomed Univ Rome, Dept Orthopaed & Trauma Surg, Via Alvaro Portillo 200, Rome, Italy
关键词
Intramedullary; Extramedullary; Femoral cut; Alignment; TKA; COMPUTER NAVIGATION; COMPONENT ALIGNMENT; EXTRAMEDULLARY; ACCURACY; OUTCOMES; SYSTEMS; GUIDES; METAANALYSIS; SURVIVAL;
D O I
10.1186/s40634-022-00563-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Clinical outcomes and overall alignment after total knee arthroplasty (TKA) depend on femoral component positioning in the sagittal and the coronal plane, making choice of the distal femoral cutting guide crucial. Currently, there is no consensus on the potential advantage of an extramedullary (EM) guide compared to an intramedullary (IM) guide in TKA. The IM guide is the most widely used system for making the distal femoral cut although evidence for its superiority over the EM guide is lacking. However, inaccuracies arising with the IM guide include location of the rod entry point in the coronal plane, femoral canal diameter, femoral bowing, and structural features of the rod. Furthermore, the invasive procedure is associated with increased risk of postoperative blood loss, thromboembolic complications, and intraoperative fractures. While the EM guide has no such difficulties, its accuracy depends on the instruments used. Studies have reported results not inferior to the IM guide and a lower number of postoperative complications. Patient-specific instrumentation (PSI) and robotic and computer-assisted TKA have achieved excellent clinical and radiographic results and can overcome the problems inherent to the IM and the EM guide. Authors performed a systematic review of the literature and proposed a narrative review to summarize the characteristics of the IM and the EM guide and compare the advantages and disadvantages of each, as well as their limitations in comparison with new technologies. Authors also expressed their expert opinion.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Is the femoral intramedullary alignment already actual in total knee arthroplasty?
    Andrea Tecame
    Andrea Gambineri
    Pierangelo Za
    Paolo Adravanti
    Journal of Experimental Orthopaedics, 10
  • [2] The variability of intramedullary alignment of the femoral component during total knee arthroplasty
    Mihalko, WM
    Boyle, J
    Clark, LD
    Krackow, KA
    JOURNAL OF ARTHROPLASTY, 2005, 20 (01): : 25 - 28
  • [3] Unusual complication associated with femoral intramedullary alignment guide in total knee arthroplasty
    Yau, WP
    Ng, TP
    Chiu, KY
    JOURNAL OF ARTHROPLASTY, 2001, 16 (02): : 247 - 249
  • [4] The accuracy of the extramedullary and intramedullary femoral alignment system in total knee arthroplasty for varus osteoarthritic knee
    Woon-hwa Jung
    Chung-woo Chun
    Ji-hoon Lee
    Jae-hun Ha
    Jae-Heon Jeong
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 629 - 635
  • [5] The accuracy of the extramedullary and intramedullary femoral alignment system in total knee arthroplasty for varus osteoarthritic knee
    Jung, Woon-hwa
    Chun, Chung-woo
    Lee, Ji-hoon
    Ha, Jae-hun
    Jeong, Jae-Heon
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (03) : 629 - 635
  • [6] Femoral Intramedullary Alignment in Total Knee Arthroplasty: Indications, Results, Pitfalls, Alternatives, and Controversies
    Bono, Olivia J.
    Olcott, Christopher W.
    Carangelo, Robert
    Jamison, James P.
    Tigges, Russell G.
    Talmo, Carl T.
    Bono, James, V
    JOURNAL OF KNEE SURGERY, 2020, 33 (01) : 12 - 14
  • [7] Deviation of femoral intramedullary alignment rod influences coronal and sagittal alignment during total knee arthroplasty
    Haruta, Yohei
    Kawahara, Shinya
    Tsuchimochi, Kanenobu
    Hamasaki, Akihiko
    Hara, Toshihiko
    KNEE, 2018, 25 (04): : 644 - 649
  • [8] THE EFFICACY OF INTRAMEDULLARY FEMORAL ALIGNMENT IN TOTAL KNEE REPLACEMENT
    TETER, KE
    BREGMAN, D
    COLWELL, CW
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (321) : 117 - 121
  • [9] The accuracy of femoral intramedullary guides in total knee arthroplasty
    Reed, SC
    Gollish, J
    JOURNAL OF ARTHROPLASTY, 1997, 12 (06): : 677 - 682
  • [10] Rotation of intramedullary alignment rods affects distal femoral cutting plane in total knee arthroplasty
    Günther Maderbacher
    Jan Matussek
    Armin Keshmiri
    Felix Greimel
    Clemens Baier
    Joachim Grifka
    Hermann Maderbacher
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 3311 - 3316