Safety and adverse events of EUS-guided gallbladder drainage using lumen-apposing metal stents and percutaneous cholecystostomy tubes: a systematic review and meta-analysis

被引:9
|
作者
Hayat, Umar [1 ]
Al Shabeeb, Reem [2 ]
Perez, Paola [4 ]
Hensien, Jack [4 ]
Dwivedi, Aanini [4 ]
Sakhawat, Usama [5 ]
Ahmad, Oneeb [5 ]
Haseeb, Muhammad [6 ]
Siddiqui, Ali A. [3 ]
Adler, Douglas G. [7 ,8 ]
机构
[1] Geisinger Wyoming Valley Med Ctr, Dept Internal Med, Div Gastroenterol, Wilkes Barre, PA USA
[2] Inova Fairfax Med Campus, Dept Internal Med, Falls Church, VA USA
[3] Inova Fairfax Med Campus, Div Gastroenterol, Falls Church, VA USA
[4] Univ Virginia, Sch Med, Charlottesville, VA USA
[5] UHS Wilson Med Ctr, Dept Internal Med, Binghamton, NY USA
[6] Beth Israel Deaconess Med Ctr, Hospitalist Med, Boston, MA USA
[7] Porter Adventist Hosp, Ctr Adv Therapeut Endoscopy, Denver, CO USA
[8] Porter Adventist Hosp, Ctr Adv Therapeut Endoscopy CATE Centura Hlth, 2525 S Downing St, Denver, CO 80210 USA
关键词
ACUTE CHOLECYSTITIS; RISK;
D O I
10.1016/j.gie.2023.10.043
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aos: EUS-guided gallbladder drainage using lumen-apposing metal stents (EUS-GBD-LAMSs) and percutaneous cholecystostomy for gallbladder drainage (PTGBD) are the alternative treatment modalities in high -risk surgical patients with acute cholecystitis (AC). The aim of this study was to compare the safety of these procedures for AC in surgically suboptimal candidates. Methods: Six studies compared the 2 groups' early, delayed, and overall adverse events; they also compared length of hospital stay, re-interventions, and re-admissions rate. A random effect model calculated odds ratios (ORs) with a 95% confidence interval (CI). Results: The 2 groups had similar early adverse events; however, EUS-GBD-LAMS was associated with a lower rate of delayed (OR, .21; 95% CI, .07-.61; P <= .01) and overall (OR, .43; 95% CI, .30-.61; P <= .01) adverse events. Patients with EUS-GBD-LAMSs had a shorter hospital stay than PTGBD. Conclusions: EUS-GBD-LAMS is a safer option than PTGBD and is associated with a shorter hospital stay in nonsurgical candidates with AC. (Gastrointest Endosc 2024;99:444-8.)
引用
收藏
页码:444 / 448.e1
页数:6
相关论文
共 50 条
  • [1] Adverse events with lumen-apposing metal stents in endoscopic gallbladder drainage: A systematic review and meta-analysis
    Mohan, Babu P.
    Asokkumar, Ravishankar
    Shakhatreh, Mohammed
    Garg, Rajat
    Ponnada, Suresh
    Navaneethan, Udayakumar
    Adler, Douglas G.
    ENDOSCOPIC ULTRASOUND, 2019, 8 (04) : 241 - 248
  • [2] Indirect comparison of various lumen-apposing metal stents for EUS-guided biliary and gallbladder drainage: a systematic review and meta-analysis
    Singh, Sahib
    Kumar, Vishnu Charan Suresh
    Aswath, Ganesh
    Khan, Muzaffar Akbar
    Sapkota, Bishnu
    Vinayek, Rakesh
    Dutta, Sudhir
    Dahiya, Dushyant Singh
    Inamdar, Sumant
    Mohan, Babu P.
    Sharma, Neil
    Adler, Douglas G.
    GASTROINTESTINAL ENDOSCOPY, 2024, 100 (05)
  • [3] Effectiveness and safety of EUS-guided choledochoduodenostomy using lumen-apposing metal stents (LAMS): a systematic review and meta-analysis
    Rajesh Krishnamoorthi
    Chandra S. Dasari
    Viveksandeep Thoguluva Chandrasekar
    Harshith Priyan
    Mahendran Jayaraj
    Joanna Law
    Michael Larsen
    Richard Kozarek
    Andrew Ross
    Shayan Irani
    Surgical Endoscopy, 2020, 34 : 2866 - 2877
  • [4] Effectiveness and safety of EUS-guided choledochoduodenostomy using lumen-apposing metal stents (LAMS): a systematic review and meta-analysis
    Krishnamoorthi, Rajesh
    Dasari, Chandra S.
    Thoguluva Chandrasekar, Viveksandeep
    Priyan, Harshith
    Jayaraj, Mahendran
    Law, Joanna
    Larsen, Michael
    Kozarek, Richard
    Ross, Andrew
    Irani, Shayan
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2020, 34 (07): : 2866 - 2877
  • [5] EUS-guided gallbladder drainage with a lumen-apposing metal stent (with video)
    Irani, Shayan
    Baron, Todd H.
    Grimm, Ian S.
    Khashab, Mouen A.
    GASTROINTESTINAL ENDOSCOPY, 2015, 82 (06) : 1110 - 1115
  • [6] EUS-guided drainage of postsurgical pelvic abscesses using lumen-apposing metal stents
    Lopez-Fernandez, Eduardo
    Ruiz-Zorrilla, Rafael
    Curieses-Luengo, Maria
    Alvarez-Alvaree, Aranzazu
    de-la-Coba-Ortiz, Cristobal
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2019, 111 (07) : 566 - 567
  • [7] Efficacy and Safety of Lumen-apposing Metal Stents in EUS Guided Transmural Drainage of Pancreatic Fluid Collections: A Systematic Review and Meta-analysis
    Hammad, Tariq
    Khan, Muhammad Ali
    Alastal, Yaseen
    Sharaiha, Reem Z.
    Tyberg, Amy
    Nawras, Ali
    Kahaleh, Michel
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2016, 111 : S16 - S16
  • [8] Efficacy and Safety of Lumen Apposing Self-Expandable Metal Stents for EUS Guided Cholecystostomy: A Meta-Analysis and Systematic Review
    Kalva, Nikhil R.
    Vanar, Vishwas
    Forcione, David
    Bechtold, Matthew L.
    Puli, Srinivas Reddy
    CANADIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2018, 2018
  • [9] Adverse events in endoscopic ultrasound-guided choledochoduodenostomy with lumen-apposing metal stents: A systematic review and meta-analysis
    Li, Jia-Su
    Tang, Jian
    Fang, Jun
    Li, Zhao-Shen
    Liu, Feng
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2024, 39 (09) : 1769 - 1779
  • [10] COMPARSION OF EUS-GUIDED CHOLECYSTOGASTROSTOMY AND CHOLECYSTODUODENOSTOMY WITH LUMEN-APPOSING METAL STENT FOR GALLBLADDER DRAINAGE
    Ling, Christina
    Paleti, Swathi
    Rustagi, Tarun