Preoperative planning using virtual reality and computed tomography angiogram in deep inferior epigastric perforator flap breast reconstruction

被引:0
|
作者
Ioschpe, Anais Di Via [1 ]
Golijanin, Borivoj [1 ]
Benharush, David [2 ]
Berl, Ariel [3 ]
Perhulov, Vladimir [5 ]
Egozi, Dana [2 ,4 ,6 ]
机构
[1] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[2] Kaplan Med Ctr, Dept Plast Surg, Rehovot, Israel
[3] Meir Med Ctr, Dept Plast Surg, Kefar Sava, Israel
[4] Hebrew Univ Jerusalem, Fac Med, Jerusalem, Israel
[5] Kaplan Med Ctr, Dept Radiol, Rehovot, Israel
[6] Hebrew Univ Med Sch, Kaplan Med Ctr, Dept Plast Surg, 1 Pasternak St, Rehovot, Israel
关键词
Computed tomography angiography; Deep inferior epigastric perforator; Virtual reality; AUGMENTED REALITY;
D O I
10.1016/j.bjps.2023.08.004
中图分类号
R61 [外科手术学];
学科分类号
摘要
The gold standard for preoperative planning of deep inferior epigastric perforator (DIEP) flap breast reconstruction uses computed tomography angiography (CTA). Virtual reality (VR) circumnavigates the limitations of CTA by reconstructing a fully immersive and interactive 3D representation of the scan. Scans of 44 patients who underwent DIEP flap breast reconstruction were retrospectively reviewed and compared using CTA and VR imaging modalities. The objective of this research was to compare perforators found using VR to the ones identified using conventional CTA. A correlation was found between the imaging modalities for unilateral (R = 0.96 (CI = 0.92, 0.98)) and bilateral (R = 0.93, (CI = 0.83, 0.97)) DIEP flap surgeries when comparing perforator location related to the umbilicus. Multivariable ordinal logistic regression found that higher intramuscular course length (IMC) is associated with the number of perforators found per side (OR = 1.79 (CI = 1.24, 2.6)), and medial location (OR = 2.85 (CI = 1.38, 5.87)). Larger vessel caliber (VC) is associated with shorter IMC (T2 vs. T3, OR = 3.34 (CI = 1.49, 7.49)), and branching in adipose tissue (AB) is associated with higher VC (T1 vs. T3, OR = 0.02 (CI = 0.007, 0.08); T2 vs. T3, OR = 0.24 (CI = 0.11, 0.55)). Overall, preoperative planning using VR was easy to use, safe, more intuitive, and provided in a time
引用
收藏
页码:161 / 169
页数:9
相关论文
共 50 条
  • [1] Preoperative Computed Tomographic Angiogram for Deep Inferior Epigastric Artery Perforator Flap Breast Reconstruction
    Masia, Jaume
    Kosutic, Damir
    Clavero, Juan A.
    Larranaga, Jose
    Vives, Lorena
    Pons, Gemma
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2010, 26 (01) : 21 - 28
  • [2] Using Virtual Reality for Deep Inferior Epigastric Perforator Flap Preoperative Planning
    Freidin, Dor
    Singolda, Roei
    Tejman-Yarden, Shai
    Parmat, Yisrael
    Liran, Alon
    Ofir, Hagit
    Saukhat, Olga
    Haik, Josef
    Barnea, Yoav
    Tessone, Ariel
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2023, 11 (01) : E4773
  • [3] Advantages of Preoperative Computed Tomography in Deep Inferior Epigastric Artery Perforator Flap Breast Reconstruction
    Rozen, Warren M.
    Chubb, Daniel
    Ashton, Mark W.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2009, 124 (04) : 1367 - 1368
  • [4] Advantages of Preoperative Computed Tomography in Deep Inferior Epigastric Artery Perforator Flap Breast Reconstruction
    Casey, William J., III
    Chew, Roderick T.
    Rebecca, Alanna M.
    Smith, Anthony A.
    Collins, Joseph M.
    Pockaj, Barbara A.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2009, 123 (04) : 1148 - 1155
  • [5] Advantages of Preoperative Computed Tomography in Deep Inferior Epigastric Artery Perforator Flap Breast Reconstruction Reply
    Casey, William J.
    Rebecca, Alanna M.
    Smith, Anthony A.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2009, 124 (04) : 1368 - 1368
  • [6] Computed tomography angiography (CTA) assisted preoperative planning and volume calculation of deep inferior epigastric artery perforator (DIEP) flap for breast reconstruction
    Ronen G.
    Blachar A.
    Abelow A.
    Gur E.
    Barnea Y.
    European Journal of Plastic Surgery, 2017, 40 (5) : 441 - 446
  • [7] DEEP INFERIOR EPIGASTRIC PERFORATOR FLAP FOR BREAST RECONSTRUCTION
    ALLEN, RJ
    TREECE, P
    ANNALS OF PLASTIC SURGERY, 1994, 32 (01) : 32 - 38
  • [8] Breast reconstruction using deep inferior epigastric artery perforator flap
    Kim, Jeong Tae
    Kim, Youn Hwan
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2011, 54 (01): : 35 - 43
  • [9] Optimising the preoperative planning of deep inferior epigastric perforator flaps for breast reconstruction
    Casares Santiago, Miguel
    Garcia-Tutor, Emilio
    Rodriguez Caravaca, Gil
    del Cerro Gonzalez, Julian
    Marie Klein, Lea
    Alonso-Burgos, Alberto
    EUROPEAN RADIOLOGY, 2014, 24 (09) : 2097 - 2108
  • [10] Optimising the preoperative planning of deep inferior epigastric perforator flaps for breast reconstruction
    Miguel Casares Santiago
    Emilio García-Tutor
    Gil Rodríguez Caravaca
    Julián del Cerro González
    Léa Marie Klein
    Alberto Alonso-Burgos
    European Radiology, 2014, 24 : 2097 - 2108