grid-forming photovoltaic grid-connected converter; transient synchronous stability; asymmetric grid faults; grid code; SYNCHRONIZATION STABILITY;
D O I
10.3390/en17061399
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Compared with the traditional grid-following photovoltaic grid-connected converter (GFL-PGC), the grid-forming photovoltaic grid-connected converter (GFM-PGC) can provide voltage and frequency support for power systems, which can effectively enhance the stability of power electronic power systems. Consequently, GFM-PGCs have attracted great attention in recent years. When an asymmetrical short-circuit fault occurs in the power grid, GFM-PGC systems may experience transient instability, which has been less studied so far. In this paper, a GFM-PGC system is investigated under asymmetrical short-circuit fault conditions. A novel Q-V droop control structure is proposed by improving the traditional droop control. The proposed control structure enables the system to accurately control the positive- and negative-sequence reactive current without switching the control strategy during the low-voltage ride-through (LVRT) period so that it can meet the requirements of the renewable energy grid code. In addition, a dual-loop control structure model of positive- and negative-sequence voltage and current is established for the GFM-PGC system under asymmetrical short-circuit fault conditions. Based on the symmetrical component method, the composite sequence network of the system is obtained under asymmetrical short-circuit fault conditions, and positive- and negative-sequence power-angle characteristic curves are analyzed. The influence law of system parameters on the transient synchronous stability of positive- and negative-sequence systems is quantitatively analyzed through the equal area criterion. Finally, the correctness of the theoretical analysis is verified by simulation and hardware-in-the-loop experiments.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Grid-Forming Inverters for Grid-Connected Microgrids
    Tuckey, Andrew
    Round, Simon
    [J]. IEEE ELECTRIFICATION MAGAZINE, 2022, 10 (01): : 39 - 51
  • [2] Transient Stability Analysis for Grid-Forming Inverters Transitioning from Islanded to Grid-Connected Mode
    Liu, Teng
    Wang, Xiongfei
    Liu, Fangcheng
    Xin, Kai
    Liu, Yunfeng
    [J]. IEEE OPEN JOURNAL OF POWER ELECTRONICS, 2022, 3 : 419 - 432
  • [3] Improving the performance of grid-connected inverters during asymmetrical faults and unbalanced grid voltages
    Shabani, Sepideh
    Gholipour, Mehdi
    Niroomand, Mehdi
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2024, 18 (19) : 3097 - 3107
  • [4] Transient Synchronization Stability Analysis of Grid-forming Grid-connected Inverter Considering Damping Characteristics
    Li, Mingfei
    Wu, Zaijun
    Quan, Xiangjun
    Zhu, Ling
    Li, Wei
    Huang, Renzhi
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2023, 47 (15): : 198 - 207
  • [5] Stability Analysis of Grid-Connected Inverters during the Transient of Grid Voltage Fluctuations in Weak Grid Cases
    Xu, Jinming
    Bian, Shenyiyang
    Liu, Miao
    Zhang, Zhao
    Xie, Shaojun
    [J]. 2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 5185 - 5190
  • [6] Stability Control for Grid-Connected Inverters Based on Hybrid-Mode of Grid-Following and Grid-Forming
    Han, Feng
    Zhang, Xing
    Li, Ming
    Li, Fei
    Zhao, Wei
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (09) : 10750 - 10760
  • [7] Collaborative Autonomous Grid-Connected Inverters Flexible grid-forming inverter control for the future grid
    Benzaquen, Joseph
    Miranbeigi, Mohammadreza
    Kandula, Prasad
    Divan, Deepak
    [J]. IEEE ELECTRIFICATION MAGAZINE, 2022, 10 (01): : 22 - 29
  • [8] Transient stability analysis of a grid-connected type-4 wind turbine with grid-forming control during the fault
    Gao, Zhen
    Du, Wenjuan
    Wang, H. F.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 155
  • [9] Transient Stability of Grid-Forming Inverters in Microgrids: Nonlinear Analysis
    Eskandari, Mohsen
    Savkin, Andrey, V
    [J]. 16TH IEEE INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION, ROBOTICS AND VISION (ICARCV 2020), 2020, : 1156 - 1159
  • [10] Active Power Enhancement Control Strategy of Grid-Forming Inverters Under Asymmetrical Grid Faults
    Zhang, Han
    Liu, Rui
    Xue, Cheng
    Li, Yunwei
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (01) : 1447 - 1459