An optimal initialisation for robust model reference adaptive PI controller for grid-tied power systems under unbalanced grid conditions

被引:5
|
作者
Evald, Paulo Jefferson Dias de Oliveira [1 ]
Hollweg, Guilherme Vieira [2 ]
Borin, Lucas Cielo [3 ]
Mattos, Everson [3 ]
Tambara, Rodrigo Varella [3 ]
Montagner, Vinicius Folleto [3 ]
Gruendling, Hilton Abilio [3 ]
机构
[1] Univ Fed Pelotas, Intelligent Syst & Control Grp, Pelotas, Brazil
[2] Univ Michigan, Dept Elect & Comp Engn, Dearborn, MI USA
[3] Univ Fed Santa Maria, Grp Power Elect & Control, Santa Maria, Brazil
关键词
Genetic algorithms; Automatic controllers; PI-RMRAC; Grid-tied inverters; LCL filter; LCL FILTER DESIGN; CONNECTED INVERTER; PREDICTIVE CONTROL; RENEWABLE ENERGY; FOSSIL-FUEL; CONVERTERS; STABILITY;
D O I
10.1016/j.engappai.2023.106589
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents an Optimal Robust Model Reference Adaptive Proportional-Integral controller for grid -tied power systems, which is automatically parametrised using a Genetic Algorithm. The task of choosing the adaptation rate and the controller's initial gains set is now performed in a computational and automatic way, saving design time and ensuring satisfactory transient regimes.The use of a Genetic Algorithm for complete parametrisation of robust adaptive controllers applied to renewable energy power generation systems with LCL filter is first here explored. Five cost functions are considered in the optimisation process. A comparison of simulation results applying the optimised controller in a grid-tied Voltage Source Inverter with LCL filter points out the benefits and drawbacks of using each cost function. A framework for performance analysis and an in-depth discussion are provided. The function determined as the best one, which is integral of absolute error, is used in the controller implemented experimentally, ensuring suitable tracking of grid current references and rejection of grid voltage harmonics, even under unbalanced grid voltage conditions. An experimental comparison in a three-phase 6.75 kW power converter with the non-optimised controller is also provided, where the optimised controller obtains a reduction in the overshoot in all transient regimes and smaller tracking error, resulting in a reduction in the mean error of 14.31% and 60.30% in ������ and ������ coordinates, respectively. In addition, the optimised controller reduces total harmonic content, improving energy quality. This parametrisation procedure can be immediately extended to the control of any other power converter systems.
引用
收藏
页数:26
相关论文
共 50 条
  • [1] Model predictive power control for grid-tied inverters under unbalanced and distorted grid conditions
    Zhang, Zhi
    Kang, Longyun
    Hu, Bihua
    ENERGY REPORTS, 2022, 8 : 9946 - 9957
  • [2] Grid-tied converter operated under unbalanced and distorted grid voltage conditions
    Galecki, A.
    Michalczuk, M.
    Kaszewski, A.
    Ufnalski, B.
    Grzesiak, L. M.
    BULLETIN OF THE POLISH ACADEMY OF SCIENCES-TECHNICAL SCIENCES, 2020, 68 (02) : 389 - 398
  • [3] Voltage support control algorithm based on reactive power injection for grid-tied converters under unbalanced grid conditions
    Choi, Jaehoon
    Suh, Yongsug
    JOURNAL OF POWER ELECTRONICS, 2025,
  • [4] Symmetrical Component Model for a Transformerless, Grid-Tied Current Controlled Inverter under Unbalanced Conditions
    Harzig, Thibaut
    Al Hassan, Hashim A.
    Grainger, Brandon M.
    2019 IEEE 20TH WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS (COMPEL), 2019,
  • [5] Optimization of Robust PI Controllers for Grid-Tied Inverters
    Osorio, Caio R. D.
    Borin, Lucas C.
    Koch, Gustavo G.
    Montagner, Vinicius F.
    2019 IEEE 15TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 5TH IEEE SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2019,
  • [6] Comparative Experimental Study of Predictive and Resonant Controllers of Grid-Tied Inverter under Unbalanced Grid Conditions
    Mohapatra, Soumya Ranjan
    Agarwal, Vivek
    2019 1ST IEEE INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY TECHNOLOGIES AND SYSTEMS (IEEE-ICSETS 2019), 2019, : 030 - 035
  • [7] A novel controller for harmonics reduction of grid-tied converters in unbalanced networks
    Thai Vo
    Ravishankar, Jayashri
    Nurdin, Hendra I.
    Fletcher, John
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 155 : 296 - 306
  • [8] Small-Signal Stability of MMC Grid-Tied System Under Two Typical Unbalanced Grid Conditions
    Zhu, Jianhang
    Hu, Jiabing
    Li, Yingbiao
    Ma, Shicong
    Wang, Tiezhu
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (04) : 5005 - 5014
  • [9] Instantaneous Complex Power Controller for a Grid-Tied Inverter Connected to an Unknown Grid
    Solsona, Jorge A.
    Jorge, Sebastian Gomez
    Busada, Claudio A.
    Tapia-Otaegui, Gerardo
    Susperregui, Ana
    Martinez, M. Itsaso
    2024 IEEE BIENNIAL CONGRESS OF ARGENTINA, ARGENCON 2024, 2024,
  • [10] A robust adaptive One Sample Ahead Preview controller for grid-injected currents of a grid-tied power converter with an LCL filter
    Milbradt, Deise Maria Cirolini
    Hollweg, Guilherme Vieira
    Evald, Paulo Jefferson Dias de Oliveira
    Silveira, Wagner Barreto da
    Gruendling, Hilton Abilio
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 142