Fully convolutional neural network and PPG signal for arterial blood pressure waveform estimation

被引:1
|
作者
Zhou, Yongan [1 ]
Tan, Zhi [1 ]
Liu, Yuhong [2 ,3 ]
Cheng, Haibo [4 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Sch Elect & Informat Engn, Beijing 100044, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Coll Pulm & Crit Care Med, Med Ctr 8, Beijing, Peoples R China
[3] Beijing IROT Key Lab, Beijing, Peoples R China
[4] Jiangsu Future Network Grp Co Ltd, Nanjing, Peoples R China
关键词
arterial blood pressure waveform; photoplethysmogram; deep learning; non-invasive; NET;
D O I
10.1088/1361-6579/ace414
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. The quality of the arterial blood pressure (ABP) waveform is crucial for predicting the value of blood pressure. The ABP waveform is predicted through experiments, and then Systolic blood pressure (SBP), Diastolic blood pressure, (DBP), and Mean arterial pressure (MAP) information are estimated from the ABP waveform. Approach. To ensure the quality of the predicted ABP waveform, this paper carefully designs the network structure, input signal, loss function, and structural parameters. A fully convolutional neural network (CNN) MultiResUNet3+ is used as the core architecture of ABP-MultiNet3+. In addition to performing Kalman filtering on the original photoplethysmogram (PPG) signal, its first-order derivative and second-order derivative signals are used as ABP-MultiNet3+ enter. The model's loss function uses a combination of mean absolute error (MAE) and means square error (MSE) loss to ensure that the predicted ABP waveform matches the reference waveform. Main results. The proposed ABP-MultiNet3+ model was tested on the public MIMIC II databases, MAE of MAP, DBP, and SBP was 1.88 mmHg, 3.11 mmHg, and 4.45 mmHg, respectively, indicating a small model error. It experiment fully meets the standards of the AAMI standard and obtains level A in the DBP and MAP prediction standard test under the BHS standard. For SBP prediction, it obtains level B in the BHS standard test. Although it does not reach level A, it has a certain improvement compared with the existing methods. Significance. The results show that this algorithm can achieve sleeveless blood pressure estimation, which may enable mobile medical devices to continuously monitor blood pressure and greatly reduce the harm caused by Cardiovascular disease (CVD).
引用
收藏
页数:15
相关论文
共 50 条
  • [1] BLOOD PRESSURE ESTIMATION FROM PPG SIGNALS USING CONVOLUTIONAL NEURAL NETWORKS AND SIAMESE NETWORK
    Schlesinger, Oded
    Vigderhouse, Nitai
    Eytan, Danny
    Moshe, Yair
    [J]. 2020 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2020, : 1135 - 1139
  • [2] A Neural Network-based Method for Continuous Blood Pressure Estimation from a PPG Signal
    Kurylyak, Yuriy
    Lamonaca, Francesco
    Grimaldi, Domenico
    [J]. 2013 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2013, : 280 - 283
  • [3] A device employing a neural network for blood pressure estimation from the oscillatory pressure pulse wave and PPG signal
    Tian, Jian
    Xie, Jiangan
    He, Zhonghua
    Ma, Qianfeng
    Wang, Xiuxin
    [J]. SENSOR REVIEW, 2021, 41 (01) : 74 - 86
  • [4] A device for blood pressure estimation from oscillatory pressure pulse wave and PPG signal based on the neural network
    Tian, Jian
    Xie, Jiangan
    He, Zhonghua
    Jiang, Yuhao
    Lu, Yi
    Wang, Xiuxin
    [J]. BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2018, 124 : 21 - 21
  • [5] Central Aortic Blood Pressure Waveform Estimation with a Temporal Convolutional Network
    Liu, Wenyan
    Du, Shuo
    Pang, Na
    Zhang, Liangyu
    Sun, Guozhe
    Xiao, Hanguang
    Zhao, Qi
    Xu, Lisheng
    Yao, Yudong
    Alastruey, Jordi
    Avolio, Alberto
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2023, 27 (07) : 3622 - 3632
  • [6] Blood Pressure Evaluation From Ppg Signal Analysis and Artificial Neural Network
    Lamonaca, Francesco
    Spagnuolo, Vitaliano
    De Prisco, Serena
    Carni, Domenico L.
    Grimaldi, Domenico
    [J]. HYPERTENSION, 2017, 70
  • [7] Continuous Blood Pressure Estimation from PPG Signal
    Slapnicar, Gasper
    Lustrek, Mitja
    Marinko, Matej
    [J]. INFORMATICA-JOURNAL OF COMPUTING AND INFORMATICS, 2018, 42 (01): : 33 - 42
  • [8] Continuous blood pressure estimation from PPG signal
    [J]. 2018, Slovene Society Informatika (42):
  • [9] Repetitive neural network (RNN) based blood pressure estimation using PPG and ECG signals
    Senturk, Umit
    Yucedag, Ibrahim
    Polat, Kemal
    [J]. 2018 2ND INTERNATIONAL SYMPOSIUM ON MULTIDISCIPLINARY STUDIES AND INNOVATIVE TECHNOLOGIES (ISMSIT), 2018, : 188 - 191
  • [10] Schrodinger Spectrum Based PPG Features for the Estimation of the Arterial Blood Pressure
    Li, Peihao
    Laleg-Kirati, Taous-Meriem
    [J]. 42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2683 - 2686