Multiplexed elemental bioimaging with quadrupole ICP-MS and high-frequency laser ablation systems

被引:1
|
作者
Lockwood, Thomas E. [1 ]
Westerhausen, Mika T. [1 ]
Bishop, David P. [1 ]
机构
[1] Univ Technol Sydney, Hyphenated Mass Spectrometry Lab, Sydney, NSW, Australia
基金
澳大利亚研究理事会;
关键词
PLASMA-MASS SPECTROMETRY; CELL;
D O I
10.1039/d3ja00447c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The advent of fast washout and high frequency laser ablation systems has reduced blurring and greatly improved the throughput of analyses performed using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). However, historical laser synchronisation issues have limited the number of elements aquired in a single run when using quadrupole-based ICP-MS. Aliasing noise results from incorrect synchronisation between the MS acquisition time and laser firing rate, and is made more prevalent by fast washout cells. Oversampling at high Hz is a possible solution to aliasing, yet remains unexplored for the context of multiplexed elemental bioimaging. In this paper we determined the minimum laser firing rates required to prevent aliasing for any MS dwell time, and provide an equation for calculating aliasing noise. The effects of oversampling were explored using simulations and the ablation of gelatine standards and murine brains. Higher firing rates were found to reduce aliasing and increase signal, but increased the risks of sample damage and raised backgrounds. Aliasing was found to be insignificant at firing rates and dwell times greater than 200 Hz and 2 ms for a typical (20 ms full-width at 10% of maximum) fast washout cell. At these parameters, the noise from aliasing was overwhelmed by noise from other sources and synchronisation was a non-issue. This allowed facile selection of acquisition and dwell times to increase the number of targeted elements or favour those with low sensitivity. Nine elements were collected in a single analysis of a murine brain at 25 pixels per second with no visible aliasing. Use of these parameters will greatly increase throughput and multiplexing capabilities when using high frequency laser ablation with quadrupole-based ICP-MS. High-frequency lasers eliminate aliasing and the need for synchronisation. This opens the way for highly multiplexed imaging by quadrupole LA-ICP-MS.
引用
收藏
页码:1125 / 1130
页数:6
相关论文
共 50 条
  • [1] Laser ablation low-flow ICP-MS for elemental bioimaging
    Steingrobe, Tobias
    Niehoff, Ann-Christin
    Franze, Bastian
    Lenhard, Diana
    Pietsch, Hubertus
    Engelhard, Carsten
    Karst, Uwe
    Buscher, Wolfgang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (10) : 2120 - 2124
  • [2] Elemental bioimaging of haematoxylin and eosin-stained tissues by laser ablation ICP-MS
    Reifschneider, Olga
    Wehe, Christoph A.
    Diebold, Kurt
    Becker, Christoph
    Sperling, Michael
    Karst, Uwe
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (07) : 989 - 993
  • [3] Application of laser microdissection ICP-MS for high resolution elemental mapping in mouse brain tissue: A comparative study with laser ablation ICP-MS
    Sussulini, Alessandra
    Becker, J. Sabine
    TALANTA, 2015, 132 : 579 - 582
  • [4] APPLICATION OF LASER-ABLATION ICP-MS TO ELEMENTAL ANALYSIS OF GLASSES
    IMBERT, JL
    TELOUK, P
    MIKROCHIMICA ACTA, 1993, 110 (4-6) : 151 - 160
  • [5] Direct elemental analyses of ink paper by laser ablation ICP-MS
    Koenig, A
    SPECTROSCOPY, 2003, : 29 - 29
  • [6] Time-of-flight ICP-MS laser ablation zircon geochronology: assessment and comparison against quadrupole ICP-MS
    Thompson, Jay M.
    Danyushevsky, Leonid, V
    Borovinskaya, Olga
    Tanner, Martin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (10) : 2282 - 2297
  • [7] Elemental analysis of white cotton fiber evidence using solution ICP-MS and laser ablation ICP-MS (LA-ICP-MS)
    Gallo, Jenny M.
    Almirall, Jose R.
    FORENSIC SCIENCE INTERNATIONAL, 2009, 190 (1-3) : 52 - 57
  • [8] Femtosecond laser ablation ICP-MS
    Russo, RE
    Mao, XL
    Gonzalez, JJ
    Mao, SS
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (09) : 1072 - 1075
  • [9] Quantification of protein modifications by use of elemental tags and laser ablation ICP-MS
    Venkatachalam, A
    Jakubowski, N
    Feldmann, I
    Manz, A
    Koehler, C
    Roos, PH
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2006, 372 : 121 - 121
  • [10] Analysis of light lithophile elements (Li, Be, B) by laser ablation ICP-MS: Comparison between magnetic sector and quadrupole ICP-MS
    Kent, Adam J. R.
    Ungererz, C. A. Andy
    AMERICAN MINERALOGIST, 2006, 91 (8-9) : 1401 - 1411