Dehumidification load ratio: influence mechanism on air conditioning and energy saving potential analysis for building cooling

被引:1
|
作者
Jin, Zhineng [1 ]
Zheng, Yanhong [1 ]
Huang, Dongsheng [1 ]
Zhang, Yin [2 ]
Lv, Siqiang [1 ]
Sun, Hongli [1 ,3 ]
机构
[1] Sichuan Univ, Coll Architecture & Environm, Chengdu 610065, Peoples R China
[2] Southwest Minzu Univ, Sch Architecture, Chengdu 610225, Peoples R China
[3] Sichuan Univ, State Key Lab Hydraul & Mt River Engn, Chengdu 610065, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Building cooling; Air-source heat pump; Dehumidification; Energy saving potential; Load ratio; SOURCE HEAT-PUMP; CHINA CURRENT STATUS; PERFORMANCE; SYSTEM; OPTIMIZATION; TEMPERATURE; SOLAR; POWER;
D O I
10.1016/j.scs.2023.104942
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The construction energy consumption (EC) makes up around 35% of the total energy used. Half of this energy is used for air-conditioning to cool spaces. The effectiveness of cooling relates to various factors, particularly the dynamic thermal performance of air-conditioners (AC) in different conditions. Studying heat pumps in diverse hot and humid climates, especially where dehumidification matters in summer AC, reveals efficiency. Examining the connection between coefficient of performance (COP) and heat removal aids in lowering building energy usage and improving cooling systems. To achieve this, a validated thermodynamic model of heat pumps and a specific transient building heat transfer model were combined. The study focused on three distinct hot and humid climate zones: Guangzhou, Wuhan, and Jiuquan. Simulations of heat pump performance were conducted throughout the year to analyze variations in COP, relative humidity (RH), and latent heat load (LHL).Key findings indicate that the COP of heat pumps is notably influenced by the practical amount of dehumidification required. A positive correlation (correlation coefficient: 0.52151) exists between COP and LHL, emphasizing the importance of addressing dehumidification needs. The research highlights that the COP remains consistently high when the heat pump manages between 45% to 80% of the LHL. Practically, these findings have crucial implications for heat pump applications and building EC reduction, particularly in regions with pronounced dehumidification requirements during the cooling season. By understanding the interplay between heat pump efficiency, humidity, and heat load, practitioners can optimize heat pump performance to achieve energy savings. This research provides a valuable reference for designing and implementing cooling systems in various hot and humid climates, facilitating energy-efficient practices and environmentally friendly building operations.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Energy consumption research and energy saving potential analysis for an office building Air Conditioning System
    Zhang, Xu
    Wang, Suilin
    [J]. FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 392 - 396
  • [2] Energy Saving through Personal Air Conditioning by Means of Indirect Evaporative Cooling using Desiccant Dehumidification
    Osada, Motoyuki
    Kameyama, Hideo
    Sakurai, Makoto
    Watanabe, Kenji
    [J]. KAGAKU KOGAKU RONBUNSHU, 2014, 40 (04) : 313 - 319
  • [3] Detailed analysis on part load ratio characteristics and cooling energy saving of chiller staging in an office building
    Seo, Byeong Mo
    Lee, Kwang Ho
    [J]. ENERGY AND BUILDINGS, 2016, 119 : 309 - 322
  • [4] Analysis of air conditioning system of using fluid dehumidification for cooling
    Zhou, XJ
    Liu, YQ
    [J]. ISHVAC 99: 3RD INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOLS 1 AND 2, 1999, : 829 - 833
  • [5] Energy saving potential in radiant cooling system by utilizing air-conditioning condensate: A strategy for green building rating
    Dhamodharan, Palanisamy
    Ayalur, Bakthavatsalam Kannappan
    Judefelix, J.
    Prabakaran, Rajendran
    Kim, Sung Chul
    [J]. APPLIED THERMAL ENGINEERING, 2024, 236
  • [6] Numerical analysis of an air-conditioning energy-saving mechanism
    Huang, K. David
    Nguyen Anh Tuan
    [J]. BUILDING SIMULATION, 2010, 3 (01) : 63 - 73
  • [7] Study on Energy Planning and Energy Saving Analysis of Cooling and Heating Load of a Building Complex
    Zhou Yujuan
    Li Kai
    [J]. 2020 6TH INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING, 2020, 508
  • [8] Numerical analysis of an air-conditioning energy-saving mechanism
    K. David Huang
    Nguyen Anh Tuan
    [J]. Building Simulation, 2010, 3 : 63 - 73
  • [9] The energy saving potential of thermo-responsive desiccants for air dehumidification
    Zeng, Yi
    Woods, Jason
    Cui, Shuang
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 244
  • [10] Energy saving analysis of evaporative cooling composite air conditioning system for data centers
    Han, Zongwei
    Sun, Xiaoqing
    Wei, Haotian
    Ji, Qiang
    Xue, Da
    [J]. APPLIED THERMAL ENGINEERING, 2021, 186