Monitoring Variations in the Use of Automated Contouring Software

被引:1
|
作者
Nealon, Kelly A. [1 ,2 ]
Han, Eun Young [3 ]
Kry, Stephen F. [4 ]
Nguyen, Callistus [5 ]
Pham, Mary [5 ]
Reed, Valerie K. [6 ]
Rosenthal, David [6 ]
Simiele, Samantha [3 ]
Court, Laurence E. [3 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Med Sch, Boston, MA 02115 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys Patient Care, Houston, TX USA
[4] Univ Texas MD Anderson Canc Ctr, Radiat Phys Outreach, Houston, TX USA
[5] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys Res, Houston, TX USA
[6] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX USA
基金
英国惠康基金;
关键词
CLINICAL-EVALUATION; SEGMENTATION; ACCURACY;
D O I
10.1016/j.prro.2023.09.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Our purpose was to identify variations in the clinical use of automatically generated contours that could be attributed to software error, off -label use, or automation bias. Methods and Materials: For 500 head and neck patients who were contoured by an in-house automated contouring system, Dice similarity coefficient and added path length were calculated between the contours generated by the automated system and the final contours after editing for clinical use. Statistical process control was used and control charts were generated with control limits at 3 standard deviations. Contours that exceeded the thresholds were investigated to determine the cause. Moving mean control plots were then generated to identify dosimetrists who were editing less over time, which could be indicative of automation bias. Results: Major contouring edits were flagged for: 1.0% brain, 3.1% brain stem, 3.5% left cochlea, 2.9% right cochlea, 4.8% esophagus, 4.1% left eye, 4.0% right eye, 2.2% left lens, 4.9% right lens, 2.5% mandible, 11% left optic nerve, 6.1% right optic nerve, 3.8% left parotid, 5.9% right parotid, and 3.0% of spinal cord contours. Identified causes of editing included unexpected patient positioning, deviation from standard clinical practice, and disagreement between dosimetrist preference and automated contouring style. A statistically significant (P < .05) difference was identified between the contour editing practice of dosimetrists, with 1 dosimetrist editing more across all organs at risk. Eighteen percent (27/150) of moving mean control plots created for 5 dosimetrists indicated the amount of contour editing was decreasing over time, possibly corresponding to automation bias. Conclusions: The developed system was used to detect statistically significant edits caused by software error, unexpected clinical use, and automation bias. The increased ability to detect systematic errors that occur when editing automatically generated contours will improve the safety of the automatic treatment planning workflow. (c) 2023 The Authors. Published by Elsevier Inc. on behalf of American Society for Radiation Oncology.
引用
收藏
页码:e75 / e85
页数:11
相关论文
共 50 条
  • [1] Comparison of Four Software Packages for Automated Contouring
    Wallace, N.
    Murphy, G.
    Roche, M.
    Rock, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E731 - E732
  • [2] Comparative Evaluation of Four Software Packages for Automated Contouring
    Wallace, N.
    Murphy, G.
    Roche, M.
    Rock, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E107 - E107
  • [3] Independent Assessment of a Commercial Automated Contouring Software for Lung SBRT
    Kirkby, Charles
    Liu, Hong-Wei
    Ghose, Abhijit
    Grendarova, Petra
    Seberg, Stephanie
    Li, Xinzhou
    Shaw, Conor
    MEDICAL PHYSICS, 2022, 49 (08) : 5661 - 5661
  • [4] Software - Contouring explained
    Gibbs, BL
    Krajewski, SA
    GEOTIMES, 2000, 45 (10): : 38 - 38
  • [5] Automated quality monitoring and validation of the CMS reconstruction software
    Piparo, Danilo
    14TH INTERNATIONAL WORKSHOP ON ADVANCED COMPUTING AND ANALYSIS TECHNIQUES IN PHYSICS RESEARCH (ACAT 2011), 2012, 368
  • [6] Automated CTV Contouring for Prostate and Nodes Utilizing Deep Learning Contouring
    Malesevic, V.
    Potters, L.
    Riegel, A. C.
    Cao, Y.
    Baker, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [7] Evaluation of Auto Contouring Accuracy for a Commercial Software Compared to Physician Contouring
    Liu, X.
    Zheng, Y.
    MEDICAL PHYSICS, 2022, 49 (06) : E774 - E775
  • [8] Variations in the Contouring of important Organs at Risk
    Grone, J.
    Meyners, J.
    Delfs, B.
    Mangangou, A-W
    Burke, E.
    Muru, A.
    Failing, T.
    Schoenfeld, A.
    Stelljes, T. S.
    Poppe, B.
    Willborn, K. C.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 : S47 - S48
  • [9] AUTOMATED CONTOURING FOR AIRBORNE GAMMA SPECTROMETRY
    GRASTY, RL
    GEOPHYSICS, 1971, 36 (06) : 1264 - &
  • [10] Contouring using different software packages
    El, Ghazouly, Hassan G.
    AEJ - Alexandria Engineering Journal, 2001, 40 (05): : 757 - 767