Fretting corrosion testing of acetabular modular tapers for total hip replacements: A comparison of two designs

被引:1
|
作者
Mace, Annsley [1 ]
Goodwin, Charley M. [1 ]
Gilbert, Jeremy L. [1 ]
机构
[1] Clemson Univ, MUSC Bioengn Program, Charleston, SC 29634 USA
关键词
acetabular implant testing; acetabular taper; fretting corrosion; modular orthopedic implant; total hip arthroplasty; RETRIEVAL; BACKSIDE; LINER; ALLOY;
D O I
10.1002/jor.25512
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Acetabular components (DePuy Pinnacle (A) and Stryker Trident (B), Ti-6Al-4V shells and CoCrMo liners) with varying geometries were assembled under a 4 kN seating load. Liner-displacement was recorded. Cyclic compression to 4 kN, R = 0.01, 9 Hz was applied for three million cycles to evaluate fretting corrosion currents (n = 5). Fretting currents, load-displacement, ion dissolution, and disassembly loads were used to compare device performance. Data were analyzed using ANOVA with Tukey post hoc comparisons (p < 0.05). Liner seating displacements were not significantly different between groups. Fretting currents averaged over the initial 10 h and over three million cycles were 0.17 mu A (A) and 0.55 mu A (B) and 0.05 mu A (A) and 0.17 mu A (B), respectively (p = 0.19). No variation in ion averages between A and B (0.23 and 0.45 ppm for Ti [p = 0.21], 0.63 and 0.85 ppm for Co [p = 0.47]) existed. Average push-out forces, -2.41 (A) and -2.42 kN (B), were not significantly different (p = 0.97). SEM and EDS showed some titanium and metal oxide transfer from the shell to the liner in both designs. Overall, both implant designs exhibited very minor MACC in these experiments. This study demonstrates quantitative measures of in vitro fretting corrosion over the course of three million cycles and the minimal degree of acetabular taper damage. Clinical Significance: Retrieval studies show dual mobility acetabular shell-liner tapers with metal-on-metal contacts are susceptible to fretting corrosion in vivo.
引用
收藏
页码:1738 / 1745
页数:8
相关论文
共 50 条
  • [1] Fretting corrosion fatigue study of modular joints in total hip replacements by accelerated in vitro testing
    Bhambri, SK
    Gilbertson, LN
    [J]. MODULARITY OF ORTHOPEDIC IMPLANTS, 1997, 1301 : 146 - 156
  • [2] FRETTING CORROSION ACCELERATES CREVICE CORROSION OF MODULAR HIP TAPERS
    BROWN, SA
    FLEMMING, CAC
    KAWALEC, JS
    PLACKO, HE
    VASSAUX, C
    MERRITT, K
    PAYER, JH
    KRAAY, MJ
    [J]. JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (01) : 19 - 26
  • [3] Effect of impact assembly on the fretting corrosion of modular hip tapers
    Mroczkowski, ML
    Hertzler, JS
    Humphrey, SM
    Johnson, T
    Blanchard, CR
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (02) : 271 - 279
  • [4] In vitro corrosion testing of modular hip tapers
    Goldberg, JR
    Gilbert, JL
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2003, 64B (02) : 78 - 93
  • [5] Accelerated Fretting Corrosion Testing of Modular Necks for Total Hip Arthroplasty
    Nambu, Satya
    Obert, Richard
    Roark, Michael
    Delvechhio, Eleonora
    Linton, Dough
    Bible, Scott
    Moseley, Jon
    [J]. MODULARITY AND TAPERS IN TOTAL JOINT REPLACEMENT DEVICES, 2015, 1591 : 237 - 258
  • [6] WEAR AND CORROSION OF MODULAR INTERFACES IN TOTAL HIP REPLACEMENTS
    COOK, SD
    BARRACK, RL
    BAFFES, GC
    CLEMOW, AJT
    SEREKIAN, P
    DONG, N
    KESTER, MA
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (298) : 80 - 88
  • [7] Are Corrosion and Material Loss a Threat for Titanium-Titanium Tapers in Total Hip Arthroplasty Modular Acetabular Components?
    Spece, Hannah
    Ouellette, Eric S.
    Klein, Gregg R.
    Mont, Michael A.
    Kurtz, Steven M.
    [J]. JOURNAL OF ARTHROPLASTY, 2024, 39 (06): : 1602 - 1608
  • [8] Corrosion on the Acetabular Liner Taper from Retrieved Modular Metal-on-Metal Total Hip Replacements
    Gascoyne, Trevor C.
    Dyrkacz, Richard M.
    Turgeon, Thomas R.
    Burnell, Colin D.
    Wyss, Urs P.
    Brandt, Jan-M.
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (10): : 2049 - 2052
  • [9] Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements
    Hallab, NJ
    Messina, C
    Skipor, A
    Jacobs, JJ
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (02) : 250 - 259
  • [10] In vitro test methods for seating and fretting corrosion behavior of modular metal-on-metal acetabular tapers
    Shenoy, Aarti A.
    Gilbert, Jeremy L.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2020, 38 (05) : 1089 - 1100