Experimental Investigation of the Effect of Transient Overvoltages on XLPE-Insulated HVDC Cables

被引:3
|
作者
Diban, Bassel [1 ]
Mazzanti, Giovanni [1 ]
Mazzocchetti, Laura [2 ]
Seri, Paolo [1 ]
机构
[1] Alma Mater Studiorum Univ Bologna, Dept Elect Elect & Informat Engn DEI, I-40136 Bologna, Italy
[2] Alma Mater Studiorum Univ Bologna, Dept Ind Chem Toso Montanari, I-40136 Bologna, Italy
关键词
Accelerated aging; cable insulation; high voltage direct-current (HVDC) transmission; impulses; spectroscopy; transient; SPACE CHARGES; RELIABILITY; POLYETHYLENE; STRESS;
D O I
10.1109/TDEI.2023.3264959
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High-voltage direct-current (HVDC) cables are subject to several types of impulses superimposed on the rated dc voltage during their service lifetime. Temporary overvoltages (TOVs) and superimposed switching impulses (SSIs) are considered some of the most challenging due to the relatively long impulse duration. This article aims at investigating experimentally the effect of TOVs and SSIs on cross-linked polyethylene (XLPE) insulation for extruded HVDC cables. About 0.15-mm-thick dc-XLPE specimens, aged by applying TOVs and SSIs, are characterized using dielectric analyzer and Fourier transform infrared spectroscopy (FTIR) to detect the aging effects on the insulation. Results show an increase in the imaginary part of permittivity, epsilon '', accompanied with the appearance of additional dipolar polarization losses peaks. The amplitude and frequency of the aforementioned peaks vary with the amplitude and the number of applied TOVs and SSIs. An increase in electrical conductivity is also noticed with aging. FTIR results show absorbance peaks in the aged specimens likely due to the intramolecular bonds rupture accompanied with the formation of aging products. In summary, SSIs and TOVs cause a noticeable reduction of insulating properties in XLPE specimens. The higher the peak of the transient, the greater the aging effect.
引用
收藏
页码:1779 / 1786
页数:8
相关论文
共 50 条
  • [1] Preliminary Experimental Investigation of the Effect of Superimposed Switching Impulses on XLPE-insulated HVDC Cables
    Mazzanti, Giovanni
    Seri, Paolo
    Diban, Bassel
    2021 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2021, : 169 - 172
  • [2] The Effect of Superimposed Switching Impulses on Space Charge Accumulation in XLPE-insulated HVDC Cables
    Diban, B.
    Mazzanti, G.
    Seri, P.
    2023 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, CEIDP, 2023,
  • [3] XLPE-Insulated Cables Temperature Monitoring for the Determination of Their Residual Life
    Pugach, V. N.
    Polyakov, D. A.
    Nikitin, Konstantin I.
    Yurchuk, D. A.
    2017 XI INTERNATIONAL IEEE SCIENTIFIC AND TECHNICAL CONFERENCE DYNAMICS OF SYSTEMS, MECHANISMS AND MACHINES (DYNAMICS), 2017,
  • [4] Critical issues in the PD testing methodology for XLPE-insulated MV cables: an experimental case
    Madonia, Antonino
    Sanseverino, Eleonora Riva
    Troia, Ivan
    Bononi, Stefano Franchi
    Giannini, Simone
    Mazzanti, Giovanni
    2017 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENON (CEIDP), 2017, : 311 - 314
  • [6] New watertight 10-20 kV XLPE-insulated cables
    Anon
    Sahko, 1988, 61 (06): : 51 - 52
  • [7] Space Charge and Electric Field Characteristics in XLPE-Insulated Extrusion Molded Joint for HVDC Submarine Cables: Experiment and Simulation
    Li, Zhonglei
    Zheng, Zhong
    Wu, You
    Du, Boxue
    IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (04) : 2317 - 2326
  • [8] Preliminary Experimental Investigation of the Effect of Long Temporary Overvoltages on the Reliability of HVDC Extruded Cables
    Mazzanti, G.
    Seri, P.
    Diban, B.
    Stagni, S.
    PROCEEDINGS OF THE 2020 3RD IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD 2020), 2020, : 49 - 52
  • [9] On-Site Diagnostic Tests on Medium Voltage, XLPE-Insulated Power Cables
    Abou Dakka, Mahmoud
    Bulinski, Alexander
    Bamji, Soli
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 3019 - 3024
  • [10] Post-irradiation effect analysis on XLPE-insulated LV cables used in nuclear power plants
    Suraci, Simone Vincenzo
    Fabiani, Davide
    Li, Chuanyang
    2019 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE 2019), 2019, : 53 - 56