Reduced night ventilation did not impair indoor air quality for occupants in a sample of Finnish school and daycare buildings

被引:2
|
作者
Kuurola, Pentti [1 ]
Raunima, Tuomas [2 ]
Ketko, Joonas [2 ]
Toyinbo, Oluyemi [1 ]
Vinha, Juha [2 ]
Haverinen-Shaughnessy, Ulla [1 ,2 ]
机构
[1] Univ Oulu, Fac Technol, POB 8000, FI-90014 Oulu, Finland
[2] Tampere Univ, Fac Built Environm, FI-33014 Tampere, Finland
基金
芬兰科学院;
关键词
IAQ; IEQ; Mixed models; MM questionnaire; Survey; Reduced night ventilation; Schools; Daycare centers; Finland; ADAPTIVE THERMAL COMFORT; ENVIRONMENTAL-QUALITY; HEALTH; ASSOCIATION; STRATEGIES; STUDENTS; WORK;
D O I
10.1016/j.enbuild.2023.113470
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ventilation in buildings plays a significant role from the points of view of indoor air quality, health and comfort. In addition, ventilation is one major consumer of heating energy in buildings. In this study, we investigated the effects of shutting down mechanical ventilation at nights on measured and occupant reported indoor air quality as well as health symptoms. Extensive field measurements and standard MM questionnaire surveys among school personnel and children were carried out three months before and three months after changing the ventilation operation mode (from 24 h ventilation to shutting down when unoccupied) in twelve school and daycare buildings. There were small differences in the estimated mean indoor temperature, relative humidity, and particle concentrations results before and after the operation mode change (intervention), which could also be related to seasonal factors. However, the intervention did not associate with any of the studied occupant outcomes, including reported thermal comfort, stuffy 'bad' air, or health symptoms among children or personnel. Therefore, according to the survey responses, shutting down ventilation at night had no noticeable effects on the perceived indoor air quality and health during occupancy.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Actual energy performance and indoor climate in Finnish NZEB daycare and school buildings
    Ahmed, Kaiser
    Hasu, Tero
    Kurnitski, Jarek
    JOURNAL OF BUILDING ENGINEERING, 2022, 56
  • [2] Actual energy performance and indoor climate in Finnish NZEB daycare and school buildings
    Ahmed, Kaiser
    Hasu, Tero
    Kurnitski, Jarek
    JOURNAL OF BUILDING ENGINEERING, 2022, 56
  • [3] Effects of Night Ventilation on Indoor Air Quality in Educational Buildings-A Field Study
    Lestinen, Sami
    Kilpelainen, Simo
    Kosonen, Risto
    Valkonen, Maria
    Jokisalo, Juha
    Pasanen, Pertti
    APPLIED SCIENCES-BASEL, 2021, 11 (09):
  • [4] Measurement of indoor air quality for ventilation with the existence of occupants in schools
    Shin, HS
    Ahn, YC
    Lee, JK
    Kang, TW
    Lee, KG
    Park, HS
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2762 - 2766
  • [5] Measurement of indoor air quality for ventilation with the existence of occupants in schools
    Hee-Soo Shin
    Jai-Kwon Lee
    Young-Chull Ahn
    Chang-Shin Yeo
    Sang-Hyun Byun
    Jae-Keun Lee
    Tae-Wook Kang
    Kam-Gyu Lee
    Hyo-Soon Park
    Journal of Mechanical Science and Technology, 2005, 19 : 1001 - 1005
  • [6] Measurement of indoor air quality for ventilation with the existence of occupants in schools
    Shin, HS
    Lee, JK
    Ahn, YC
    Yeo, CS
    Byun, SH
    Lee, JK
    Kang, TW
    Lee, KG
    Park, HS
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2005, 19 (04) : 1001 - 1005
  • [7] IMPACT OF REDUCED INFILTRATION AND VENTILATION ON INDOOR AIR-QUALITY IN RESIDENTIAL BUILDINGS
    HOLLOWELL, CD
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1978, 20 (12): : 60 - 60
  • [8] Ventilation and indoor air quality in office buildings
    Pan, YQ
    Long, WD
    Fan, CY
    INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 225 - 229
  • [9] Impact of different mechanical ventilation strategies for night purging on indoor air quality in public buildings
    Lestinen, Sami
    Kilpelainen, Simo
    Kosonen, Risto
    Jokisalo, Juha
    COLD CLIMATE HVAC & ENERGY 2021, 2021, 246
  • [10] Modelling of occupants' subjective responses and indoor air quality in office buildings
    Welling, I
    Kähkönen, E
    Lahtinen, M
    Salmi, K
    Lampinen, J
    Kostiainen, T
    PROGRESS IN MODERN VENTILATION, VOL 2, PROCEEDINGS, 2000, : 45 - 49