Clinical and radiographic outcomes of implant-supported zirconia fixed dental prostheses with cantilever extension: A proof-of-principle study with a follow-up of at least 1 year

被引:6
|
作者
Roccuzzo, Andrea [1 ,2 ]
Morandini, Michele [1 ]
Stahli, Alexandra [1 ]
Imber, Jean-Claude [1 ]
Sculean, Anton [1 ]
Salvi, Giovanni E. [1 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Periodontol, Bern, Switzerland
[2] Univ Bern, Sch Dent Med, Dept Periodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
关键词
biological complications; bone loss; cantilever extension; dental implants; fixed dental prostheses; technical complications; PARTIALLY EDENTULOUS PATIENTS; PARTIAL DENTURES; AESTHETIC COMPLICATIONS; SINGLE CROWNS; SURVIVAL RATE; RATES; FDPS;
D O I
10.1111/clr.14138
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To test the reliability of full zirconia implant-supported fixed dental prostheses with cantilever extension (FDPCs) after at least 1 year of function. Materials and Methods: Thirty-five patients in need of implant-supported single unit crowns (SUC) and FDPCs in posterior areas were enrolled. After implant placement, patients were rehabilitated with screw-retained full-zirconia FDPCs. Implant survival rate, pocket probing depth (PPD), presence/absence of bleeding on probing (BoP), and presence/absence of mechanical/technical complications were recorded. Mesial and distal radiographic marginal bone levels (mBLs) from baseline (i.e., recall appointment 3-6 months after implant loading [T0]) to the follow-up examination (i.e., latest recall appointment after at least 12 months after T0 [T1]), were calculated. Results: Thirty patients with 34 FDPCs (31 SUCs and 3 FDPs) supported by 37 implants were available for analysis after a mean loading time of 2.6 +/- 1.5 years (range: 13-87 months). No implants were lost. MBLs and mean PPD values did not change statistically significantly from T0 to T1 from 0.92 mm +/- 0.42 to 0.96 mm +/- 0.38 (95% CI: - 0.07/0.17; p =.418) and from 2.99 mm +/- 0.70 to 3.27 mm +/- 0.71 (95% CI: - 0.11/0.68; p =.25) respectively. Peri-implant mucositis was diagnosed in 22 cases. Screw-loosening and zirconia chipping occurred 1x in 4 patients. Conclusion: Within the limitations of the present proof-of-principle study, the use of full-zirconia FDPCs in posterior areas seems a valid and safe short-term treatment option.
引用
收藏
页码:1073 / 1082
页数:10
相关论文
共 50 条
  • [1] Clinical and radiographic outcomes of implant-supported fixed dental prostheses with cantilever extension. A retrospective cohort study with a follow-up of at least 10 years
    Schmid, Eric
    Morandini, Michele
    Roccuzzo, Andrea
    Ramseier, Christoph A.
    Sculean, Anton
    Salvi, Giovanni E.
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (12) : 1243 - 1252
  • [2] Clinical and radiographic outcomes of implant-supported fixed prostheses with cantilever extension in anterior mandible: A retrospective study
    Wang, Siyuan
    Chen, Xiaoyu
    Ling, Zhaoting
    Xie, Yiwen
    Chen, Cong
    Shen, Xiaoting
    He, Fuming
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (09) : 1180 - 1192
  • [3] COMPLETE MOUTH RECONSTRUCTION WITH IMPLANT-SUPPORTED FIXED PARTIAL DENTAL PROSTHESES FABRICATED WITH ZIRCONIA FRAMEWORKS: A 4-YEAR CLINICAL FOLLOW-UP
    Puri, Shweta
    Parciak, Ewa C.
    Kattadiyil, Mathew T.
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (03): : 397 - 401
  • [4] Implant survival rates and biologic complications with implant-supported fixed complete dental prostheses: A retrospective study with up to 12-year follow-up
    Papaspyridakos, Panos
    Bordin, Thaisa Barizan
    Kim, Yong-Jeong
    DeFuria, Catherine
    Pagni, Sarah E.
    Chochlidakis, Konstantinos
    Teixeira, Eduardo Rolim
    Weber, Hans-Peter
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (08) : 881 - 893
  • [5] Survival and complications of implant-supported cantilever fixed dental prostheses with zirconia and metal frameworks: A retrospective cohort study
    Horsch, Laura
    Kronsteiner, Dorothea
    Rammelsberg, Peter
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (05) : 621 - 629
  • [6] Clinical and radiographic evaluation of implant-supported single-unit crowns with cantilever extension in posterior areas: A retrospective study with a follow-up of at least 10 years
    Schmid, Eric
    Roccuzzo, Andrea
    Morandini, Michele
    Ramseier, Christoph A.
    Sculean, Anton
    Salvi, Giovanni E.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (02) : 189 - 196
  • [7] Ten-Year Follow-Up of Implant-Supported All-Ceramic Fixed Dental Prostheses: A Randomized, Prospective Clinical Trial
    Larsson, Christel
    von Steyern, Per Vult
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (01) : 31 - 34
  • [8] FIXED IMPLANT-SUPPORTED PROSTHESES IN THE EDENTULOUS MAXILLA - A 5-YEAR FOLLOW-UP REPORT
    JEMT, T
    CLINICAL ORAL IMPLANTS RESEARCH, 1994, 5 (03) : 142 - 147
  • [9] Peri-implant mucosal level in patients treated with implant-supported fixed prostheses:: A 1-year follow-up study
    Ekfeldt, A
    Eriksson, A
    Johansson, LÅ
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2003, 16 (05) : 529 - 532
  • [10] Five year clinical outcomes of metal ceramic and zirconia-based implant-supported dental prostheses: A retrospective study
    Nejatidanesh, Farahnaz
    Abbasi, Mahsa
    Savabi, Ghazal
    Bonakdarchian, Morteza
    Atash, Ramin
    Savabi, Omid
    JOURNAL OF DENTISTRY, 2020, 100