Oval Root Canals Prepared With Two Different Endodontic Rotary Files: An In Vitro Study Comparing the Incidence of Dental Defects

被引:1
|
作者
Bhavsar, Bhavika A. [1 ]
Sharma, Pranjely [1 ]
Surana, Pratik [2 ]
Badnaware, Sheetal [3 ]
Jadhaw, Dimple [4 ]
Jain, Arvind [4 ]
机构
[1] RKDF Dent Coll & Res Ctr, Dept Conservat Dent & Endodont, Bhopal, India
[2] Maitri Coll Dent & Res Ctr, Dept Pedodont & Prevent Dent, Durg, India
[3] Banaras Hindu Univ, Fac Dent Sci, Dept Pedodont & Prevent Dent, Varanasi, Uttar Pradesh, India
[4] Govt Coll Dent, Dept Conservat Dent & Endodont, Indore, India
关键词
tooth wear; dentin; fracture; cracked teeth; sem; PROTAPER UNIVERSAL; ENLARGEMENT; CRACKS; HAND; GOLD;
D O I
10.7759/cureus.35914
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study aims to investigate and compare the establishment of dentinal cracks during root canal preparation using a stereomicroscope and a scanning electron microscope (SEM). Materials and methods: Sixty removed human mandibular premolars were separated into three groups of 20: two experimental and one control. Within the randomized controlled experimental groups, root canals were constructed. Group I: the Waldent walflex file and Group II: the Trunatomy (TRN) file. Group III: the control group received no preparations. The surfaces of the roots were checked for dentinal cracks using a stereomicroscope and SEM following sectioning at 3, 6, and 9 mm from the apex. The Chi-square test was used to examine the data. Results: In the control group, no fissures appeared. Cracks in Waldent Walflex were almost 66.7% between the 3mm and 6mm range. At both the 6 mm and 9 mm levels, there was no statistically significant difference between the experimental groups (P > 0.05). Defects were found to be substantially higher in the apical region of samples than in the median and coronal sections. Conclusion: Dentinal fissures were created by every rotary file used in the tests. There were more flaws in the Waldent Walflex file group than in the Trunatomy file group.
引用
收藏
页数:7
相关论文
共 41 条
  • [1] Dentinal Defects Induced by Offset and Alternating Contact Endodontic Rotary Files: An In Vitro Study
    Abass, Abeer A.
    Fadhil, Haidar T.
    Albaaj, Firas S. O. S.
    DENTAL HYPOTHESES, 2022, 13 (02): : 53 - 56
  • [2] Evaluation of the apical seal in root canals prepared with a new rotary system and obturated with a methacrylate based endodontic sealer: An in vitro study
    Zmener, O
    Pameijer, CH
    Macri, E
    JOURNAL OF ENDODONTICS, 2005, 31 (05) : 392 - 395
  • [3] Comparative assessment of cleaning efficacy of two exclusive paediatric rotary files in root canals of primary teeth: An in vitro study
    Bhattacharjee, Abhisek
    Singh, Rajeev Kumar
    Patil, Ranjit Kumar
    Chandra, Shaleen
    Singhai, Atin
    Singh, Uma Shankar
    Ansari, Afroz Alam
    Khanna, Richa
    INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, 2024, 34 (04) : 474 - 484
  • [4] Comparison of Surface Defects in Different Rotary Files: An in- Vitro Study
    Chopra, Krish
    Ballal, Nidambur Vasudev
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2025, 25
  • [5] EFFECTIVENESS OF DIFFERENT ENDODONTIC FILES FOR PREPARING CURVED ROOT CANALS - A SCANNING ELECTRON-MICROSCOPIC STUDY
    ZMENER, O
    MARRERO, G
    ENDODONTICS & DENTAL TRAUMATOLOGY, 1992, 8 (03): : 99 - 103
  • [6] Evaluating Two Techniques on Removal of Fractured Rotary Nickel-Titanium Endodontic Instruments from Root Canals: An In Vitro Study
    Alomairy, Khalid H.
    JOURNAL OF ENDODONTICS, 2009, 35 (04) : 559 - 562
  • [7] Evaluation of Apical Transportation in Root Canals Prepared with Hand File and Two Rotary Files by Cone Beam Computed Tomography
    Haghanifar, Sina
    Hosseini, Reza
    Hassanabadi, Mehran Ebrahimzadeh
    Charati, Jamshid Yazdani
    Mesgarani, Abbas
    Kohsar, Azam Haddadi
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2018, 6 (01): : 418 - 424
  • [8] Effect of coronal flaring on the working length in curved root canals using different nickel-titanium rotary files and hand stainless steel files - an in vitro comparative study
    Kumar, Rahul
    Khambete, Neha
    ENDO-ENDODONTIC PRACTICE TODAY, 2013, 7 (02): : 113 - 119
  • [9] Comparison of volumetric analysis between conventional and rotary files in the preparation of root canals in primary molars-an in vitro study
    Vishwanathaiah, Satish
    FRONTIERS IN DENTAL MEDICINE, 2024, 5
  • [10] Cleaning Efficiency of Root Canals using Different Rotary Instrumentation Systems: A Comparative In vitro Study
    Al-Khafaji, Hussein A.
    Al-Huwaizi, Hussain F.
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2019, 8 (01): : 89 - 93