Zero-Shot Medical Image Translation via Frequency-Guided Diffusion Models

被引:11
|
作者
Li, Yunxiang [1 ]
Shao, Hua-Chieh [1 ]
Liang, Xiao [1 ]
Chen, Liyuan [1 ]
Li, Ruiqi [1 ]
Jiang, Steve [1 ]
Wang, Jing [1 ]
Zhang, You [1 ]
机构
[1] UT Southwestern Med Ctr, Dept Radiat Oncol, Med Artificial Intelligence & Automat MAIA Lab, Dallas, TX 75390 USA
基金
美国国家卫生研究院;
关键词
Computed tomography; Frequency-domain analysis; Medical diagnostic imaging; Planning; Imaging; Task analysis; Low-pass filters; Medical image translation; diffusion model; cone-beam computed tomography; NETWORK; SPECTRA;
D O I
10.1109/TMI.2023.3325703
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Recently, the diffusion model has emerged as a superior generative model that can produce high quality and realistic images. However, for medical image translation, the existing diffusion models are deficient in accurately retaining structural information since the structure details of source domain images are lost during the forward diffusion process and cannot be fully recovered through learned reverse diffusion, while the integrity of anatomical structures is extremely important in medical images. For instance, errors in image translation may distort, shift, or even remove structures and tumors, leading to incorrect diagnosis and inadequate treatments. Training and conditioning diffusion models using paired source and target images with matching anatomy can help. However, such paired data are very difficult and costly to obtain, and may also reduce the robustness of the developed model to out-of-distribution testing data. We propose a frequency-guided diffusion model (FGDM) that employs frequency-domain filters to guide the diffusion model for structure-preserving image translation. Based on its design, FGDM allows zero-shot learning, as it can be trained solely on the data from the target domain, and used directly for source-to-target domain translation without any exposure to the source-domain data during training. We evaluated it on three cone-beam CT (CBCT)-to-CT translation tasks for different anatomical sites, and a cross-institutional MR imaging translation task. FGDM outperformed the state-of-the-art methods (GAN-based, VAE-based, and diffusion-based) in metrics of Frechet Inception Distance (FID), Peak Signal-to-Noise Ratio (PSNR), and Structural Similarity Index Measure (SSIM), showing its significant advantages in zero-shot medical image translation.
引用
收藏
页码:980 / 993
页数:14
相关论文
共 50 条
  • [1] Mutual Information Guided Diffusion for Zero-Shot Cross-Modality Medical Image Translation
    Wang, Zihao
    Yang, Yingyu
    Chen, Yuzhou
    Yuan, Tingting
    Sermesant, Maxime
    Delingette, Herve
    Wu, Ona
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2024, 43 (08) : 2825 - 2838
  • [2] Zero-Shot Low-Light Image Enhancement via Joint Frequency Domain Priors Guided Diffusion
    He, Jinhong
    Palaiahnakote, Shivakumara
    Ning, Aoxiang
    Xue, Minglong
    IEEE SIGNAL PROCESSING LETTERS, 2025, 32 : 1091 - 1095
  • [3] Zero-shot Image-to-Image Translation
    Parmar, Gaurav
    Singh, Krishna Kumar
    Zhang, Richard
    Li, Yijun
    Lu, Jingwan
    Zhu, Jun-Yan
    PROCEEDINGS OF SIGGRAPH 2023 CONFERENCE PAPERS, SIGGRAPH 2023, 2023,
  • [4] Text-to-Image Diffusion Models are Zero-Shot Classifiers
    Clark, Kevin
    Jaini, Priyank
    ADVANCES IN NEURAL INFORMATION PROCESSING SYSTEMS 36 (NEURIPS 2023), 2023,
  • [5] Zero-shot unsupervised image-to-image translation via exploiting semantic attributes
    Chen, Yuanqi
    Yu, Xiaoming
    Liu, Shan
    Gao, Wei
    Li, Ge
    Image and Vision Computing, 2022, 124
  • [6] Zero-shot unsupervised image-to-image translation via exploiting semantic attributes
    Chen, Yuanqi
    Yu, Xiaoming
    Liu, Shan
    Gao, Wei
    Li, Ge
    IMAGE AND VISION COMPUTING, 2022, 124
  • [7] SIMSAM: ZERO-SHOT MEDICAL IMAGE SEGMENTATION VIA SIMULATED INTERACTION
    Towle, Benjamin
    Chen, Xin
    Zhou, Ke
    IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, ISBI 2024, 2024,
  • [8] SIMSAM: ZERO-SHOT MEDICAL IMAGE SEGMENTATION VIA SIMULATED INTERACTION
    Towle, Benjamin
    Chen, Xin
    Zhou, Ke
    arXiv,
  • [9] ZERO-SHOT MEDICAL IMAGE ARTIFACT REDUCTION
    Chen, Yu-Jen
    Chang, Yen-Jung
    Wen, Shao-Cheng
    Shi, Yiyu
    Xu, Xiaowei
    Ho, Tsung-Yi
    Jia, Qianjun
    Huang, Meiping
    Zhuang, Jian
    2020 IEEE 17TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2020), 2020, : 862 - 866
  • [10] Zero-Shot Low-Dose CT Image Denoising via Patch-Based Content-Guided Diffusion Models
    Su, Bo
    Hu, Xiangyun
    Zha, Yunfei
    Wu, Zijun
    Ma, Yuncheng
    Xu, Jiabo
    Zhang, Baochang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74