A novel method of combined desulfurization and heat utilization of low-temperature flue gas from hot blast stove for blast furnace: Laboratory research and industrial application

被引:0
|
作者
Meng, Dongxiang [1 ]
Wei, Rufei [1 ]
Long, Hongming [1 ,2 ]
Li, Jun [1 ,3 ,4 ]
Zhang, Feihu [1 ]
Wang, Hui [4 ]
机构
[1] Anhui Univ Technol, Sch Met Engn, Maanshan 243032, Anhui, Peoples R China
[2] Anhui Univ Technol, Key Lab Met Emiss Reduct & Resources Recycling, Minist Educ, Maanshan 243032, Peoples R China
[3] Kunshan Yushun Environm Protect Technol Co Ltd, Res & Dev Dept, Suzhou 215332, Peoples R China
[4] Nanjing Iron & Steel Grp Co Ltd, Nanjing Jinhan Environm Protect Technol Co Ltd, Nanjing 210000, Peoples R China
关键词
Desulfurization; Waste Heat utilization; Metallurgical coke drying; Flue Gas; Hot Blast Stove for Blast furnace; STEEL-INDUSTRY; ADSORPTION; IRON; SO2;
D O I
10.1016/j.fuproc.2023.107983
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
To address the challenges of low waste heat utilization rates and high desulfurization costs, this study proposes a novel method for combined desulfurization and heat utilization of low-temperature flue gas. By utilizing the lowtemperature flue gas from hot blast stoves to dry lump metallurgical coke, the method also achieves flue gas desulfurization during the lump coke drying process. During the drying process, the wet lump coke desulfurizes due to the reaction between water vapor in the lump coke and the SO2 and oxygen in the flue gas, resulting in the formation of sulfuric acid. Additionally, the coke powder generated by friction during the drying process of lump coke has a large specific surface area, enabling it to adsorb additional quantities of SO2 and enhance the desulfurization process. It's important to note that the lump coke itself does not exhibit adsorption properties towards SO2 during the drying process, and the gas is not retained within the lump coke. Industrial applications indicate the outlet flue gas temperature is reduced from 175 degrees C to 60 degrees C, and the concentration of SO2 in the outlet flue gas is reduced from 150 mg/m3 to 29 mg/m3.
引用
收藏
页数:10
相关论文
共 6 条
  • [1] A Novel Exhaust Gas Temperature Prediction Method of Hot Blast Stove
    Yang, Yinghua
    Zhao, Xin
    Liu, Xiaozhi
    PROCEEDINGS OF THE 39TH CHINESE CONTROL CONFERENCE, 2020, : 5916 - 5921
  • [2] Effect of NaOH addition on the reactivities of iron blast furnace slag/hydrated lime sorbents for low-temperature flue gas desulfurization
    Liu, CF
    Shih, SM
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2004, 43 (01) : 184 - 189
  • [3] A Novel Echo State Network and Its Application in Temperature Prediction of Exhaust Gas From Hot Blast Stove
    Yang, Yinghua
    Zhao, Xin
    Liu, Xiaozhi
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (12) : 9465 - 9476
  • [4] Application Research on Pd-Co-Ti Catalyst for Purifying CO in Flue Gas of Hot-blast Stove in Steel Rolling Mill
    Cai J.
    Yu Z.
    He J.
    Li J.
    Strategic Planning for Energy and the Environment, 2021, 40 (04) : 455 - 470
  • [5] A novel resource utilization method using wet magnesia flue gas desulfurization residue for simultaneous removal of ammonium nitrogen and heavy metal pollutants from vanadium containing industrial wastewater
    Fang, Dean
    Zhang, Xuefei
    Xue, Xiangxin
    RSC ADVANCES, 2018, 8 (66): : 38013 - 38021
  • [6] Power by waste heat recovery from low temperature industrial flue gas by Organic Flash Cycle (OFC) and transcritical-CO2 power cycle: A comparative study through combined thermodynamic and economic analysis
    Mondal, Subha
    De, Sudipta
    ENERGY, 2017, 121 : 832 - 840