Development and validation of a novel system that combines a new masticatory simulator and analysis method for modeling the human gummy candy masticatory process

被引:1
|
作者
Kanda, Reina [1 ,2 ]
Inoue, Motoki [1 ]
Hisajima, Tomoko [1 ]
Toyama, Yoshio [1 ]
机构
[1] Meiji Co Ltd, R&D Div, Tokyo, Japan
[2] Meiji Co Ltd, R&D Div, 1-29-1 Nanakuni,Hachioji, Tokyo 1920919, Japan
关键词
bolus formation; masseter muscle activity; mastication process simulator; ORAL-MAPS; simulating mastication; ORAL-HEALTH; TONGUE; SALIVA; IMPACT; ELECTROMYOGRAPHY; ASSOCIATION; PERFORMANCE; FRAILTY; MOUTH; FLOW;
D O I
10.1111/jtxs.12804
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
During mastication, food undergoes state and texture changes influenced by various mechanical properties, including compression and fracturing of the molar teeth, mixing with saliva, and oral temperature. Prior studies have explored mastication simulators, however, no studies have assessed the forces and duration applied to the molars by the food during bolus formation. In this study, we developed a novel system that integrates a masticatory simulator and analysis method to evaluate mechanical properties. We developed ORAL-MAPS which is equipped with 6-axis force sensor, pneumatic pressure control mechanism, vertical movement, molar-like module, artificial saliva injection unit, and temperature control apparatus. A gap exists between the upper and lower unit at the closest point, allowing the sensor to measure vertical upward force and duration from food, while compressed air provides constant downward pressure. We hypothesized a correlation between the total integrated muscle activity ratio obtained from the human masseter muscle electromyography (iEMG). We compared the normalized impulse obtained from ORAL-MAPS with the normalized total iEMG obtained from human studies with four different types of gummy candies. As a result, the normalized total impulse of gummy candies A, B, C, and D were 1.00 +/- 0.00, 1.29 +/- 0.06, 0.95 +/- 0.00, and 0.39 +/- 0.0, respectively. The normalized total iEMG of the same gummy candies were 1.00 +/- 0.00, 1.23 +/- 0.15, 0.98 +/- 0.09, and 0.45 +/- 0.07, respectively. Thus, no significant difference was observed between the normalized total impulse obtained in vitro and the normalized total iEMG values for masticating the gummy candies B, C, and D (p > .05).
引用
收藏
页数:12
相关论文
共 6 条
  • [1] New Method with Experimental Validation for Power Transmission Process Analysis on Herringbone Gear Train System
    Wang Feng
    Xu Xing
    Fang Zong-de
    INTERNATIONAL JOURNAL OF ACOUSTICS AND VIBRATION, 2017, 22 (04): : 519 - 535
  • [2] Development, in vitro validation and human application of a novel method to identify arrhythmia mechanisms: The stochastic trajectory analysis of ranked signals mapping method
    Honarbakhsh, Shohreh
    Hunter, Ross J.
    Finlay, Malcolm
    Ullah, Waqas
    Keating, Emily
    Tinker, Andrew
    Schilling, Richard J.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (05) : 691 - 701
  • [3] Thermal Bridge Modeling and a Dynamic Analysis Method Using the Analogy of a Steady-State Thermal Bridge Analysis and System Identification Process for Building Energy Simulation: Methodology and Validation
    Kim, Heegang
    Yeo, Myoungsouk
    ENERGIES, 2020, 13 (17)
  • [4] Development and Validation of New Assay Method for the Simultaneous Analysis of Diltiazem, Metformin, Pioglitazone and Rosiglitazone by RP-HPLC and its Applications in Pharmaceuticals and Human Serum
    Sultana, Najma
    Arayne, M. Saeed
    Shafi, Nighat
    Siddiqui, Farhan Ahmed
    Hussain, Azhar
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2011, 49 (10) : 774 - 779
  • [5] Method Development and Validation of a Novel UHPLC Coupled with MS/MS System for the Estimation of Brivaracetam in Human (K2EDTA) Plasma Samples and its Application to Pharmacokinetic Study
    Aalapati, Kiran Kumar
    Singh, Amit
    Patnaik, Ranjana S.
    CURRENT PHARMACEUTICAL ANALYSIS, 2022, 18 (05) : 504 - 512
  • [6] Development and Interlaboratory Validation of a Novel Reproducible Qualitative Method for GM Soybeans Using Comparative Cq-Based Analysis for the Revised Non-GMO Labeling System in Japan
    Takabatake, Reona
    Egi, Tomohiro
    Soga, Keisuke
    Narushima, Jumpei
    Yoshiba, Satoko
    Shibata, Norihito
    Nakamura, Kosuke
    Kondo, Kazunari
    Kishine, Masahiro
    Mano, Junichi
    Kitta, Kazumi
    ANALYTICAL CHEMISTRY, 2022, 94 (39) : 13447 - 13454