Confinement Reinforcement of High-Strength Reinforced Concrete Tied Columns under High Axial Load

被引:1
|
作者
Shen, Wen-Cheng [1 ,2 ]
Hwang, Shyh-Jiann [1 ,3 ]
机构
[1] Natl Ctr Res Earthquake Engn, Taipei, Taiwan
[2] Natl Taiwan Ocean Univ, Keelung, Taiwan
[3] Univ Calif Berkeley, Berkeley, CA USA
关键词
confinement crosstie; high axial load; high -strength concrete; high -strength reinforcement; lateral drift capacity; reinforced concrete; column; seismic hook;
D O I
10.14359/51738505,
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The use of high-strength concrete (HSC) in high-rise buildings can reduce the size of structural members and increase the resi-dential space. However, the behavior of HSC at ultimate loads is more brittle than that of normal-strength concrete. Hence, the ACI 318-19 building code requires that all the column longitudinal bars be confined by seismic hooks when using HSC (f(c)' > 70 MPa [10.15 ksi]) or under high axial loads (P-u > 0.3A(g)f(c)'). The require-ment for crossties with seismic hooks at both ends might cause a huge impact on the assemblage of the column reinforcement cage during field installation. This research proposes an experimental study of full-scale column specimens with a 600 x 600 mm (23.62 x 23.62 in.) cross-sectional dimension subjected to quasi-static cyclic loading under constant high axial load. These column spec-imens are composed of both HSC and high-strength reinforcement. Test results show that if crossties with a 90-degree hook at one end are alternated, the column specimen maintains satisfactory seismic performance. This change in detailing can facilitate the field instal-lation of the reinforcement cage for columns using HSC or under high axial loads.
引用
收藏
页码:145 / 155
页数:11
相关论文
共 50 条
  • [1] Axial load behavior of reinforced concrete columns with high-strength steel coiled strips as confinement
    Barbachyn, Steven M.
    O'Donnell, Anne
    Thrall, Ashley P.
    Kurama, Yahya C.
    PCI JOURNAL, 2023, 68 (05): : 21 - 41
  • [2] Axial Load Response of Ultra-High-Strength Concrete Columns and High-Strength Reinforcement
    Shin, Hyun-Oh
    Yoon, Young-Soo
    Cook, William D.
    Mitchell, Denis
    ACI STRUCTURAL JOURNAL, 2016, 113 (02) : 325 - 336
  • [3] Behavior and modeling of high-strength concrete tied columns under axial compression
    Lee, Hung-Jen
    Lai, Yi-Lin
    Chen, Chia-Wei
    Tao, Chi-Chun
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2018, 41 (04) : 353 - 365
  • [4] Ductility of ultra high-strength concrete tied columns under combined axial load and lateral force
    Kim, J. K.
    Yoo, S. H.
    Han, B. S.
    Shin, S. W.
    ADVANCES IN FRACTURE AND DAMAGE MECHANICS VI, 2007, 348-349 : 609 - +
  • [5] A model of confined concrete in high-strength reinforced concrete tied columns
    Han, BS
    Shin, SW
    Bahn, BY
    MAGAZINE OF CONCRETE RESEARCH, 2003, 55 (03) : 203 - 214
  • [6] High Strength Concrete Columns under Axial Compression Load: Hybrid Confinement Efficiency of High Strength Transverse Reinforcement and Steel Fibers
    Perceka, Wisena
    Liao, Wen-Cheng
    Wang, Yo-de
    MATERIALS, 2016, 9 (04):
  • [7] Ductility and stiffness of slender confined reinforced high-strength concrete columns under monotonic axial load
    Ma, Chau-Khun
    Sulaiman, Muhd Fauzy
    Apandi, Nazirah
    Awang, Abdullah Zawawi
    Omar, Wahid
    Jaw, Siow-Wei
    MEASUREMENT, 2019, 146 : 838 - 845
  • [8] CONFINEMENT OF HIGH-STRENGTH CONCRETE COLUMNS
    SHEIKH, SA
    SHAH, DV
    KHOURY, SS
    ACI STRUCTURAL JOURNAL, 1994, 91 (01) : 100 - 111
  • [9] Confinement of high-strength concrete columns
    Sheikh, Shamim A.
    Shah, Dharmendra V.
    Khoury, Shafik S.
    ACI Structural Journal (American Concrete Institute), 1994, 91 (01): : 100 - 111
  • [10] High-strength concrete columns under eccentric load
    Canbay, Erdem
    Ozcebe, Guney
    Ersoy, Ugur
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2006, 132 (07): : 1052 - 1060