共 50 条
The completely patient-reported version of the American Orthopaedic Foot and Ankle Society (AOFAS) score: A valid and reliable measurement for ankle osteoarthritis
被引:7
|作者:
Paget, Liam D. A.
[1
,2
,3
,8
]
Sierevelt, Inger N.
[4
,5
]
Tol, Johannes L.
[1
,2
,3
,6
]
Kerkhoffs, Gino M. M. J.
[1
,2
,3
]
Reurink, Gustaaf
[1
,2
,3
,7
]
机构:
[1] Univ Amsterdam, Amsterdam UMC, Dept Orthoped Surg, Amsterdam Movement Sci, POB 22660, NL-1100 DD Amsterdam, Netherlands
[2] Acad Ctr Evidence Based Sports Med ACES, POB 22660, NL-1100 DD Amsterdam, Netherlands
[3] AMC VUmc IOC Res Ctr, Amsterdam Collaborat Hlth & Safety Sports ACHSS, POB 22660, NL-1100 DD Amsterdam, Netherlands
[4] Spaarne Ziekenhuis, Spaarne Gasthuis Acad, Orthoped Dept, NL-2134 TM Hoofddorp, Netherlands
[5] Xpert Clin, Specialised Ctr Orthoped Res & Educ Stichting SCOR, Orthoped Dept, NL-2134 TM Hoofddorp, Netherlands
[6] Aspetar, Orthoped & Sports Med Hosp, POB 29222, Doha, Qatar
[7] OLVG, Sports Phys Grp, Dept Sports Med, NL-1061 AE Amsterdam, Netherlands
[8] Amsterdam UMC, Dept Orthopaed, POB 22660, NL-1100 DD Amsterdam, Netherlands
关键词:
Ankle;
Ankle osteoarthritis;
Clinimetrics;
Orthopaedic surgery;
Sports medicine;
CLINICAL RATING SYSTEMS;
DUTCH LANGUAGE VERSION;
FUNCTION INDEX;
RESPONSIVENESS;
RELIABILITY;
HINDFOOT;
SF-36;
TRANSLATION;
COEFFICIENT;
COSMIN;
D O I:
10.1016/j.jisako.2023.07.003
中图分类号:
R826.8 [整形外科学];
R782.2 [口腔颌面部整形外科学];
R726.2 [小儿整形外科学];
R62 [整形外科学(修复外科学)];
学科分类号:
摘要:
Background: The American Orthopaedic Foot and Ankle score (AOFAS) is an outcome measure for ankle and hindfoot conditions, which requires scoring from both the patients and the physician. A completely patientreported version has been developed and used before, but its measurements properties are unknown. Our goal was to determine the measurement properties and the minimally important change (MIC) of a completely patientreported AOFAS (PR-AOFAS) in patients with ankle osteoarthritis. Additionally, the MIC of both the PR-AOFAS and the AOFAS was estimated, which had not previously been done.Materials and methods: The PR-AOFAS of 112 patients was evaluated for reliability, construct validity (using the AOFAS, Foot and Ankle Outcome Score, Ankle Osteoarthritis Score, Visual Analogue Scale, and Short Form-36), and responsiveness. The MIC was estimated using the optimal cut-off point of the receiver operating characteristic curve. This was a substudy of a randomized clinical trial on the efficacy of platelet-rich plasma injections for ankle osteoarthritis (OA).Results: The PR-AOFAS had sufficient construct validity, internal consistency, test-retest reliability, and responsiveness. The smallest detectable change at group level was 2.34. The MIC was 6.5 points (95% confidence interval: 0.6-14.4).Conclusions: The measurement properties of the Dutch PR-AOFAS were sufficient in patients with ankle osteoarthritis who are willing to participate in a trial on injection therapy. The minimally important change of the PRAOFAS is smaller than its smallest detectable change, making it more suitable for use in groups of patients, such as a research setting. Level of clinical evidence: 1.
引用
收藏
页码:345 / 351
页数:7
相关论文