Impact of extended versus typical rapid mixing HRTs on continuous-flow coagulation-ultrafiltration

被引:1
|
作者
Malkoske, Tyler A. [1 ]
Berube, Pierre R. [2 ]
Andrews, Robert C. [1 ]
机构
[1] Univ Toronto, Dept Civil & Mineral Engn, Toronto, ON M5S 1A4, Canada
[2] Univ British Columbia, Dept Civil Engn, Vancouver, BC V6T 1Z4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Coagulation; Ultrafiltration; HRT; Particle properties; Continuous-flow; FLOCCULATION PROCESS; VELOCITY-GRADIENT; PHYSICAL ASPECT; FERRIC SULFATE; SIMPLEX-METHOD; WATER; MICROFILTRATION; DESIGN; PERMEABILITY; AGGREGATION;
D O I
10.1016/j.seppur.2023.124041
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Although bench-scale coagulation-ultrafiltration (UF) studies are typically conducted using batch systems, continuous-flow systems allow operational parameters to be more readily evaluated and optimized over consecutive permeation cycles. When simulating coagulation-UF at bench-scale using continuous-flow systems, relevant reactor volumes require flowrates >= 1 L/min in order to achieve hydraulic retention times (HRTs) typical of full-scale rapid mixing (30 s to several minutes). In the present study, HRTs of 2 and 20 min were evaluated to determine their impact on particle properties (size, structure, and concentration) as well as UF performance (fouling resistance, reduction of natural organic matter) over a range of alum dosages. While not practical at full-scale, a 20 min HRT has been previously applied at bench-scale to reduce the overall volume of water required to conduct continuous-flow coagulation-UF studies. However, potential impacts on steady-state particle properties and subsequent UF performance not been clearly elucidated. Results from this study suggest that increasing HRT significantly increases steady-state particle size and concentration, as well as reduces total/hydraulically irre-versible UF fouling resistance and improves hydraulic cleaning efficiency. Despite reduced fouling when considering a longer HRT, significant differences in particle properties and UF performance suggest that HRT values equivalent to those typically applied during full-scale rapid mixing (30 s to several minutes) must be considered in order to produce results relevant to full-scale.
引用
收藏
页数:10
相关论文
共 6 条
  • [1] SIMPLE, RELIABLE RAPID-MIXING APPARATUS FOR CONTINUOUS-FLOW STUDIES
    DAVIS, LC
    CATE, RL
    ROCHE, TE
    ANALYTICAL BIOCHEMISTRY, 1979, 97 (02) : 428 - 437
  • [2] A CONTINUOUS-FLOW, RAPID-MIXING, PHOTOLABELING TECHNIQUE APPLIED TO THE ACETYLCHOLINE-RECEPTOR
    COX, RN
    KALDANY, RR
    BRANDT, PW
    FERREN, B
    HUDSON, RA
    KARLIN, A
    ANALYTICAL BIOCHEMISTRY, 1984, 136 (02) : 476 - 486
  • [3] RESONANCE RAMAN-SPECTROSCOPY OF REACTION INTERMEDIATES BY A RAPID MIXING, CONTINUOUS-FLOW TECHNIQUE
    WOODRUFF, WH
    SPIRO, TG
    APPLIED SPECTROSCOPY, 1974, 28 (06) : 576 - 578
  • [4] Different Impact on the Coagulation System of Two Continuous Flow LVADs: Axial Versus Centrifugal Flow
    Tarzia, V.
    Vasques, F.
    Bortolussi, G.
    Bejko, J.
    Gallo, M.
    Carrozzini, M.
    Comisso, M.
    Buratto, E.
    De Franceschi, M.
    Campello, E.
    Spiezia, L.
    Simioni, P.
    Bottio, T.
    Gerosa, G.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S177 - S177
  • [5] RATE OF CO UPTAKE BY HUMAN RED-CELLS MEASURED WITH STOP-FLOW AND CONTINUOUS-FLOW RAPID MIXING TECHNIQUES
    FORSTER, RE
    KRAWIEC, JK
    GOTTLIEBSEN, TW
    FISH, RD
    FEDERATION PROCEEDINGS, 1982, 41 (04) : 1109 - 1109
  • [6] RAPID BLOOD-PLATELET ACTIVATION - CONTINUOUS-FLOW AND QUENCHED-FLOW VERSUS STOPPED-FLOW APPROACHES - REPLY
    SAGE, SO
    RINK, TJ
    BIOCHEMICAL JOURNAL, 1990, 265 (01) : 306 - 307