Use of shear-wave elastography to distinguish complex and complicated fibroadenomas from simple fibroadenomas

被引:0
|
作者
Akin, Isil Basara [1 ]
Ozgul, Hakan [3 ]
Altay, Canan [1 ]
Secil, Mustafa [1 ]
Durak, Merih Guray [2 ]
Gurel, Duygu [2 ]
Balci, Pinar [1 ]
机构
[1] Dokuz Eylul Univ, Fac Med, Dept Radiol, Izmir, Turkiye
[2] Dokuz Eylul Univ, Fac Med, Dept Pathol, Izmir, Turkiye
[3] Kemalpasa State Hosp, Clin Radiol, Izmir, Turkiye
来源
关键词
Cellular fibroadenoma; complex fibroadenoma; complicated fibroadenoma; shearwave elastography; simple fibroadenoma; ultrasonography; CORE NEEDLE-BIOPSY; BREAST-CANCER; BI-RADS; MANAGEMENT; BENIGN; DIAGNOSIS; LESIONS; WOMEN; RISK;
D O I
10.4274/dir.2022.221615
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE Simple fibroadenomas (SFAs), complex fibroadenomas (CFAs), and cellular fibroadenomas (CeFAs) are variants of fibroadenomas. Additionally, some degenerative, hyperplastic, and metaplastic changes may occur in fibroadenomas, forming complicated fibroadenomas. Distinctive ultrasonography (US) features in variants of fibroadenomas and complicated fibroadenomas have not been reported. Shear-wave elastography (SWE) can be applied to effectively discriminate between these variants and complicated fibroadenomas. In this study, we aimed to evaluate SWE findings to discriminate between SFAs and other variants. METHODS In total, 48 patients (26 with SFAs, 16 with CFAs, 3 with CeFAs, and 3 with complicated fibroadenomas) participated in this study. The lesions were classified into two groups according to histopathologic diagnoses. The SWE evaluation and lesion elasticity scores (E-max, E-mean, and E-min) were both assessed in m/s and k/Pa, respectively. Two observers measured E-max, E-mean, and E-min. Brightness (B)-mode US findings based on the Breast Imaging Reporting and Data System categorization and elasticity scores were recorded. In the statistical analyses, the chi-square test and non-parametric tests were performed. Fisher's exact test was used to compare independent groups, and Spearman's correlation coefficients were used to correlate the SWE data between the two observers. Additionally, receiver operating characteristic curves were analyzed to evaluate the diagnostic performance of the elasticity values. RESULTS The B-mode US features in both groups showed no statistical significance. The set of SWE values of both observers demonstrated strong statistical significance in discriminating between group 1 (SFAs) and Group 2 (CFAs, CeFAs, and complicated fibroadenomas). CONCLUSION As the fibroadenoma variants and complicated fibroadenomas have similar US findings, SWE in addition to a conventional B-mode examination can increase the diagnostic performance to discriminate SFAs from other complex and complicated forms of fibroadenomas.
引用
收藏
页码:674 / 681
页数:8
相关论文
共 50 条
  • [1] Factors influencing the stiffness of fibroadenomas at shear wave elastography
    Elseedawy, M.
    Whelehan, P.
    Vinnicombe, S.
    Thomson, K.
    Evans, A.
    CLINICAL RADIOLOGY, 2016, 71 (01) : 92 - 95
  • [2] Why are some fibroadenomas stiff using shear wave elastography?
    Elseedawy, M.
    Whelehan, P.
    Vinnicombe, S.
    Thomson, K.
    Evans, A.
    BREAST CANCER RESEARCH, 2013, 15
  • [3] PB.07: Why are some fibroadenomas stiff using shear wave elastography?
    M Elseedawy
    P Whelehan
    S Vinnicombe
    K Thomson
    A Evans
    Breast Cancer Research, 15
  • [4] Texture Analysis of Ultrasound Images to Differentiate Simple Fibroadenomas From Complex Fibroadenomas and Benign Phyllodes Tumors
    Akin, Isil Basara
    Ozgul, Hakan
    Simsek, Kursat
    Altay, Canan
    Secil, Mustafa
    Balci, Pinar
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (10) : 1993 - 2003
  • [5] Inability of shear-wave elastography to distinguish malignant from benign prostate tissue - a comparison of biopsy, whole-mount sectioning and shear-wave elastography
    Porsch, Markus
    Goerner, Claudia
    Wendler, Johann Jakob
    Liehr, Uwe-Bernd
    Lux, Anke
    Siedentopf, Sandra
    Schostak, Martin
    Pech, Maciej
    JOURNAL OF ULTRASONOGRAPHY, 2016, 16 (67) : 348 - 358
  • [6] Audit of eliminating biopsy for presumed fibroadenomas with benign ultrasound greyscale and shear-wave elastography findings in women aged 25-39 years
    Evans, A.
    Sim, Y. T.
    Lawson, B.
    Whelehan, P.
    CLINICAL RADIOLOGY, 2020, 75 (11) : 880.e1 - 880.e3
  • [7] Simple and Complex Fibroadenomas Are There Any Distinguishing Sonographic Features?
    Pinto, Joana
    Aguiar, Ana Teresa
    Duarte, Halio
    Vilaverde, Filipa
    Rodrigues, Angelo
    Krug, Jose Luis
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (03) : 415 - 419
  • [8] Ultrasound shear-wave elasticity and magnetic resonance diffusion coefficient show strong inverse correlation in small fibroadenomas
    Andac Baltacioglu, Nurten
    Tureli, Derya
    MARMARA MEDICAL JOURNAL, 2021, 34 (01): : 24 - 28
  • [9] Measuring shear-wave speed with point shear-wave elastography and MR elastography: a phantom study
    Kishimoto, Riwa
    Suga, Mikio
    Koyama, Atsuhisa
    Omatsu, Tokuhiko
    Tachibana, Yasuhiko
    Ebner, Daniel K.
    Obata, Takayuki
    BMJ OPEN, 2017, 7 (01):
  • [10] Agreement and accuracy of shear-wave techniques (point shear-wave elastography and 2D-shear-wave elastography) using transient elastography as reference
    Fernandes, Flavia
    Piedade, Juliana
    Freitas, Gabriela
    Area, Philippe
    Santos, Ricardo
    Grinsztejn, Beatriz
    Veloso, Valdilea
    Pereira, Gustavo
    Perazzo, Hugo
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2022, 34 (08) : 873 - 881