Machine learning and reduced order modelling for the simulation of braided stent deployment

被引:10
|
作者
Bisighini, Beatrice [1 ,2 ,3 ]
Aguirre, Miquel [1 ,4 ,5 ]
Biancolini, Marco Evangelos [3 ]
Trovalusci, Federica [3 ]
Perrin, David [2 ]
Avril, Stephane [1 ]
Pierrat, Baptiste [1 ]
机构
[1] Univ Lyon, Univ Jean Monnet, Mines St Etienne, INSERM, St Etienne, France
[2] Grande Usine Creat 2, Predisurge, St Etienne, France
[3] Univ Tor Vergata, Dept Enterprise Engn, Rome, Italy
[4] Univ Politecn Cataluna, Lab Calcul Numer, Barcelona, Spain
[5] Gran Capita, Int Ctr Numer Methods Engn CIMNE, Barcelona, Spain
关键词
braided stent; beam elements; contact mechanics; reduced order modelling; machine learning; UNRUPTURED INTRACRANIAL ANEURYSMS; FLOW DIVERSION; SIZE RATIO; IN-VITRO; RUPTURE; PREVALENCE; VALIDATION;
D O I
10.3389/fphys.2023.1148540
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Endoluminal reconstruction using flow diverters represents a novel paradigm for the minimally invasive treatment of intracranial aneurysms. The configuration assumed by these very dense braided stents once deployed within the parent vessel is not easily predictable and medical volumetric images alone may be insufficient to plan the treatment satisfactorily. Therefore, here we propose a fast and accurate machine learning and reduced order modelling framework, based on finite element simulations, to assist practitioners in the planning and interventional stages. It consists of a first classification step to determine a priori whether a simulation will be successful (good conformity between stent and vessel) or not from a clinical perspective, followed by a regression step that provides an approximated solution of the deployed stent configuration. The latter is achieved using a non-intrusive reduced order modelling scheme that combines the proper orthogonal decomposition algorithm and Gaussian process regression. The workflow was validated on an idealized intracranial artery with a saccular aneurysm and the effect of six geometrical and surgical parameters on the outcome of stent deployment was studied. We trained six machine learning models on a dataset of varying size and obtained classifiers with up to 95% accuracy in predicting the deployment outcome. The support vector machine model outperformed the others when considering a small dataset of 50 training cases, with an accuracy of 93% and a specificity of 97%. On the other hand, real-time predictions of the stent deployed configuration were achieved with an average validation error between predicted and high-fidelity results never greater than the spatial resolution of 3D rotational angiography, the imaging technique with the best spatial resolution (0.15 mm). Such accurate predictions can be reached even with a small database of 47 simulations: by increasing the training simulations to 147, the average prediction error is reduced to 0.07 mm. These results are promising as they demonstrate the ability of these techniques to achieve simulations within a few milliseconds while retaining the mechanical realism and predictability of the stent deployed configuration.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Geometrical deployment for braided stent
    Bouillot, Pierre
    Brina, Olivier
    Ouared, Rafik
    Yilmaz, Hasan
    Farhat, Mohamed
    Erceg, Gorislav
    Lovblad, Karl-Olof
    Vargas, Maria Isabel
    Kulcsar, Zsolt
    Pereira, Vitor Mendes
    MEDICAL IMAGE ANALYSIS, 2016, 30 : 85 - 94
  • [2] Machine learning and statistical shape modelling for real-time prediction of stent deployment in realistic anatomies
    Bisighini, Beatrice
    Aguirre, Miquel
    Pierrat, Baptiste
    Avril, Stephane
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2025, 260
  • [3] Computational modeling of braided-stent deployment for interpreting the mechanism of stent flattening
    Shiozaki, Shunya
    Otani, Tomohiro
    Fujimura, Soichiro
    Takao, Hiroyuki
    Wada, Shigeo
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2021, 37 (12)
  • [4] Acoustic wave propagation simulation by reduced order modelling
    Basir, Hadi Mahdavi
    Javaherian, Abdolrahim
    Shomali, Zaher Hossein
    Firouz-Abadi, Roohollah Dehghani
    Gholamy, Shaban Ali
    EXPLORATION GEOPHYSICS, 2018, 49 (03) : 386 - 397
  • [5] Comparison of computational modelling techniques for braided stent analysis
    Kelly, Nicola
    McGrath, Donnacha J.
    Sweeney, Caoimhe A.
    Kurtenbach, Kathrin
    Grogan, James A.
    Jockenhoevel, Stefan
    O'Brien, Barry J.
    Bruzzi, Mark
    McHugh, Peter E.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (16) : 1334 - 1344
  • [6] Development of a Virtual Stent Deployment Application to Estimate Patient-Specific Braided Stent Sizes
    Fujimura, Soichiro
    Kan, Issei
    Takao, Hiroyuki
    Uchiyama, Yuya
    Ishibashi, Toshihiro
    Otani, Katharina
    Fukudome, Koji
    Murayama, Yuichi
    Yamamoto, Makoto
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 4184 - 4187
  • [7] Recent Trends in Modelling and Simulation with Machine Learning
    Trunfio, Giuseppe A.
    2020 28TH EUROMICRO INTERNATIONAL CONFERENCE ON PARALLEL, DISTRIBUTED AND NETWORK-BASED PROCESSING (PDP 2020), 2020, : 352 - 359
  • [8] Machine tool simulation based on reduced order FE models
    Fassbender, Heike
    Soppa, Andreas
    MATHEMATICS AND COMPUTERS IN SIMULATION, 2011, 82 (03) : 404 - 413
  • [9] Functional order-reduced Gaussian Processes based machine-learning emulators for probabilistic constitutive modelling
    Ding, Chensen
    Chen, Yang
    Rappel, Hussein
    Dodwell, Tim
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2023, 173
  • [10] Is reduced anticoagulation effective following optimal stent deployment?
    Robinson, NMK
    Wainwright, RJ
    Thomas, MR
    Jewitt, DE
    HEART, 1996, 75 (05) : 90 - 90