Kinematic evaluation and reliability assessment of the Nine Hole Peg Test for manual dexterity

被引:21
|
作者
Temporiti, Federico [1 ,2 ]
Mandaresu, Serena [2 ]
Calcagno, Alessandra [2 ]
Coelli, Stefania [2 ]
Bianchi, Anna Maria [2 ]
Gatti, Roberto [1 ,3 ]
Galli, Manuela [2 ]
机构
[1] Humanitas Clin & Res Ctr IRCCS, Physiotherapy Unit, Via Manzoni 56, I-20089 Milan, Italy
[2] Politecn Milan, Dept Elect Informat & Bioengn, Via Ponzio 34, Milan, Italy
[3] Humanitas Univ, Dept Biomed Sci, Via Rita Levi Montalcini 4, Milan, Italy
关键词
Manual dexterity; Kinematics; Upper limb function; Motor performance; UPPER EXTREMITY; MOTION CAPTURE; INTRA-RATER; UPPER-LIMB; HAND; FINGER; PERFORMANCE; HANDEDNESS; SHOULDER; SYSTEMS;
D O I
10.1016/j.jht.2022.01.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The Nine Hole Peg Test (NHPT) is one of the most frequently used tools to assess manual dexterity. However, no kinematic parameters are provided to describe the quality of the motor performance, since time is the only score. Purpose: To investigate test-retest and intrarater reliability, correlation with clinical test score, and discriminant validity of kinematic indexes during NHPT.Study Design: A clinical measurement study.Methods: Twenty-five healthy right-handed volunteers performed the NHPT. An experienced physiotherapist administered two sessions at a 6-hour interval with two trials for dominant and non-dominant upper limbs. An optoelectronic system was used to detect NHPT performance, which was divided into nine consecutive peg-grasp, peg-transfer, peg-in-hole, hand-return phases, and one final removing phase. Outcome measures were total and single phases times, normalized jerk, mean, peak and time-to-peak of velocity, curvature index during peg-grasp and hand-return phases, and trunk 3D displacement. The statistical analysis included Intraclass Correlation Coefficients (ICCs) for test-retest and intra-rater reliability, Pearson's coefficients for correlation with the NHPT score, and paired t-tests for discriminant validity.Results: Test-retest reliability was excellent for trunk rotation (ICC: 0.91) and good to moderate for the other indexes (ICCs: 0.89-0.61). Intra-rater reliability was excellent for total and removing times (ICCs: 0.91 and 0.94) and good to moderate for the other indexes (ICCs: 0.84-0.66), except for trunk inclination (ICC: 0.37). NHPT phases, normalized jerk, mean velocity, peak of velocity, time-to-peak and curvature index correlated with total time (r-score: 0.8-0.3). NHPT phases and most kinematic indexes discriminated the dominant from non-dominant upper limb, with the greatest effect size for normalized jerk during hand-return ( d = 1.16).Conclusions: Kinematic indexes during NHPT can be considered for manual dexterity assessment. These indexes may allow for the detection of kinematic changes responsible for NHPT score variations in healthy subjects or patients with upper limb impairments.(c) 2022 Elsevier Inc. All rights reserved.
引用
收藏
页码:560 / 567
页数:8
相关论文
共 50 条
  • [1] Nine hole peg test as a manual dexterity assesment tool in multiple sclerosis
    Xhelili, Malbora
    Gjata, Sumela
    Kruja, Jera
    MULTIPLE SCLEROSIS JOURNAL, 2023, 29 : 761 - 762
  • [2] Manual Dexterity Assessment Using a Nine-Hole Pegboard Test
    Acharya, K. Aneesha
    Choudhary, Amartya
    SMART SENSORS MEASUREMENT AND INSTRUMENTATION, CISCON 2021, 2023, 957 : 449 - 459
  • [3] The Nine-Hole Peg Test as a manual dexterity performance measure for multiple sclerosis
    Feys, Peter
    Lamers, Ilse
    Francis, Gordon
    Benedict, Ralph
    Phillips, Glenn
    LaRocca, Nicholas
    Hudson, Lynn D.
    Rudick, Richard
    MULTIPLE SCLEROSIS JOURNAL, 2017, 23 (05) : 711 - 720
  • [4] A modified standardized nine hole peg test for valid and reliable kinematic assessment of dexterity post-stroke
    Gudrun M Johansson
    Charlotte K Häger
    Journal of NeuroEngineering and Rehabilitation, 16
  • [5] A modified standardized nine hole peg test for valid and reliable kinematic assessment of dexterity post-stroke
    Johansson, Gudrun M.
    Hager, Charlotte K.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2019, 16 (1)
  • [6] Adult norms for a commercially available nine hole peg test for finger dexterity
    Grice, KO
    Vogel, KA
    Le, V
    Mitchell, A
    Muniz, S
    Vollmer, MA
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 2003, 57 (05): : 570 - 573
  • [7] Validation of the Nine Hole Peg Test as a measure of dexterity in myotonic dystrophy type 1
    Cutelle, Claudia
    Rastelli, Emanuele
    Gibellini, Manuela
    Greco, Giulia
    Frezza, Erica
    Botta, Annalisa
    Terracciano, Chiara
    Massa, Roberto
    NEUROMUSCULAR DISORDERS, 2018, 28 (11) : 947 - 951
  • [8] Reliability Test of the Digitized Device for Manual Dexterity Evaluation: A Pilot Study
    Woo, Yeshin
    Lim, Hyun Kyoon
    Doh, Il
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 2021, 75
  • [9] A round peg in a square hole? The specificity of the nine hole peg test
    McIlwaine, K
    Lane, J
    van Wijck, F
    PROCEEDINGS OF THE 2ND WORLD CONGRESS OF THE INTERNATIONAL SOCIETY OF PHYSICAL AND REHABILITATION MEDICINE - ISPRM, 2003, : 699 - 703
  • [10] Validity and Reliability of a New Developed Digital Version of Nine Hole Peg Test
    Prochaska, Eveline
    Ammenwerth, Elske
    IEEE ACCESS, 2023, 11 : 97169 - 97176