The influence of the selection of zero-crossing starting point on measurement accuracy of the absolute gravimeter

被引:0
|
作者
Mou, Zonglei [1 ]
Han, Xiao [1 ]
Hu, Ruo [2 ]
Li, Zhenfei [1 ]
Liu, Chunhui [1 ]
机构
[1] Shandong Univ Sci & Technol, Coll Elect Engn & Automat, Qingdao 266590, Peoples R China
[2] Natl Inst Metrol China, Beijing 100029, Peoples R China
基金
国家重点研发计划;
关键词
SENSITIVITY;
D O I
10.1063/5.0151822
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The absolute gravimeter is an important precision instrument for obtaining gravity acceleration in fields such as geophysics, resource survey, and national defense construction. It is greatly affected by its self-vibration during operation. If the self-vibration frequency exceeds the range of the sensor, it will not be effectively processed by the method of vibration compensation. To solve this problem, the effect of instrument self-vibration on the accuracy of gravity is analyzed through simulation and actual measurement data. Based on the calculation of the simulation data, the functional relationship between the self-vibration frequency of the instrument and the zero-crossing starting point is obtained. The Starting Point Mathematical Model is established to accurately calculate the zero-crossing starting point. Then, the zero-crossing starting point calculated by the model is taken as the time reference of the zero crossing for the least square fitting. The split and platform absolute gravity measurement systems are built, respectively, to test the measured data. The test results reveal that, compared with the traditional method using the initial falling time as the zero-crossing starting point, the proposed method can reduce the gravity deviation by 50 mu Gal and improve the accuracy by an average of 35.35% under split-type working conditions. Under platform-type working conditions, it can decrease the gravity deviation by 3 mGal and improve the accuracy by an average of 53.78%. The method proposed can reduce the fixed phase vibration interference caused by the instrument self-vibration and provide a reference for improving the measurement accuracy of the instrument under different working conditions. (c) 2023 Author(s).
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Optimal zero-crossing group selection method of the absolute gravimeter based on improved auto-regressive moving average model
    Mou, Zhonglei
    Han, Xiao
    Hu, Ruo
    [J]. CHINESE PHYSICS B, 2023, 32 (11)
  • [2] Optimal zero-crossing group selection method of the absolute gravimeter based on improved auto-regressive moving average model
    牟宗磊
    韩笑
    胡若
    [J]. Chinese Physics B, 2023, 32 (11) : 405 - 412
  • [3] BOLA based on zero-crossing point
    Ke, Li
    Jia, Liu
    [J]. 2006 IMACS: MULTICONFERENCE ON COMPUTATIONAL ENGINEERING IN SYSTEMS APPLICATIONS, VOLS 1 AND 2, 2006, : 110 - +
  • [4] COMPUTER INTERFACE FOR EFFICIENT ZERO-CROSSING INTERVAL MEASUREMENT
    NIEDERJOHN, RJ
    STICK, PP
    [J]. IEEE TRANSACTIONS ON COMPUTERS, 1975, C 24 (03) : 329 - 331
  • [5] A High-accuracy Zero-crossing Based Edge Detector
    Xu, Huilin
    [J]. 2015 8TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING (CISP), 2015, : 319 - 324
  • [6] A Zero-crossing Point Locking System in the Time-of-flight Measurement of Femtosecond Pulsed Laser
    Li, Shuyi
    Zhao, Chunbo
    Wu, Tengfei
    Han, Jibo
    [J]. OPTICAL MEASUREMENT TECHNOLOGY AND INSTRUMENTATION, 2016, 10155
  • [7] Modified watershed algorithm considering zero-crossing point of gradient
    Park, Dong-In
    Ko, Yun-Ho
    Lee, Ji-Hong
    Park, Young-Woo
    [J]. ICMIT 2007: MECHATRONICS, MEMS, AND SMART MATERIALS, PTS 1 AND 2, 2008, 6794
  • [8] The zero-crossing time difference method for measurement of loss tangent
    Wei, XL
    Ma, S
    Zhu, JL
    Chen, QG
    [J]. JOINT CONFERENCE OF 96' AICDEI / 4T-JCCEID, 1996, : 441 - 444
  • [9] Implementation of Power Measurement System with Fourier Series and Zero-Crossing Algorithm
    Chen, Yeong-Chin
    Lan, Jian-kai
    [J]. 2014 INTERNATIONAL SYMPOSIUM ON COMPUTER, CONSUMER AND CONTROL (IS3C 2014), 2014, : 601 - 604
  • [10] Accuracy assessment of the two-sample zero-crossing detection in a sinusoidal signal
    Svitlov, S.
    Rothleitner, Ch
    Wang, L. J.
    [J]. METROLOGIA, 2012, 49 (04) : 413 - 424