Quantifying Corneal Topographic Astigmatism (CorT Total) in Keratoconic Eyes

被引:0
|
作者
Alpins, Noel [1 ,2 ,3 ]
Ong, James K. Y. [4 ]
Randleman, J. Bradley [5 ]
Stamatelatos, George [1 ]
机构
[1] NewVis Clin, Melbourne, Australia
[2] Univ Melbourne, Dept Ophthalmol, Melbourne, Australia
[3] Ctr Eye Res CERA, East Melbourne, Australia
[4] ASSORT Pty Ltd, Melbourne, Australia
[5] Cleveland Clin Fdn, Cole Eye Inst, Cleveland, OH USA
关键词
HIGHER-ORDER ABERRATIONS; INTRAOCULAR LENSES; OUTCOMES; INDEXES;
D O I
10.3928/1081597X-20230103-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine optimal corneal regions from which to derive corneal topographic astigmatism (CorT) in keratoconic eyes. METHODS: In this retrospective study, potential measures of corneal astigmatism are calculated from raw total corneal power data (179 eyes from 124 patients) from a corneal tomographer. The measures are derived from annular corneal regions varying in both extent and center position, and evaluated according to the variability of the ocular residual astigmatism ( ORA) in the cohort. This variability is quantified by the ORArms, which is the root-mean-squared distance of the ORAs from their summated vector mean in double angle space. The lower the ORArms, the better the corneal astigmatism measure corresponds to manifest refractive cylinder. RESULTS: Corneal astigmatism measures derived from regions centered on corneal vertex had ORArms values (mild: 1.07 diopters [D], moderate: 1.61 D, severe: 2.65 D) as low or lower than other measures derived from regions centered on thinnest point, corneal apex (front or back), or pupil center. Corneal astigmatism measures derived from a region centered 30% of the way toward thinnest point from corneal vertex appeared to have even lower ORArms values (mild: 1.05 D, moderate: 1.45 D, severe: 2.56 D). None of the corneal astigmatism measures corresponded closely with manifest refractive cylinder for severe keratoconus (ORArms > 2.50 D). CONCLUSIONS: For keratoconic eyes, the CorT should be derived from an annular region centered 30% of the way toward thinnest point from corneal vertex, although when the keratoconus is mild, a standard corneal-vertex-centered CorT performs just as well.
引用
收藏
页码:206 / +
页数:12
相关论文
共 50 条
  • [1] Corneal Topographic Astigmatism (CorT) to Quantify Total Corneal Astigmatism
    Alpins, Noel
    Ong, James K. Y.
    Stamatelatos, George
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (03) : 182 - U110
  • [2] CORNEAL TOPOGRAPHIC ASTIGMATISM (CORT) AND TOTAL CORNEAL POWER
    Alpins, Noel
    Stamatelatos, George
    Ong, James
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 : 64 - 64
  • [3] Corneal Topographic Astigmatism Based on Total Corneal Power Data (CorT Total): A Benchmark for Total Corneal Astigmatism
    Alpins, Noel
    Ong, James K. Y.
    Randleman, J. Bradley
    Nevyas-Wallace, Anita
    Stamatelatos, George
    [J]. CORNEA, 2020, 39 (04) : 431 - 436
  • [4] Accuracy of total corneal topographic astigmatism (CORT total) compared to total keratometry (TK)
    Alpins, Noel
    Ong, James
    Stamatelatos, George
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 47 : 45 - 45
  • [5] Improving corneal astigmatism measures for keratoconic eyes
    Alpins, Noel
    Ong, James K. Y.
    Stamatelatos, George
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 946 - 946
  • [6] AN ALTERNATIVE MEASURE OF CORNEAL ASTIGMATISM THAT CORRESPONDS TO MANIFEST REFRACTIVE CYLINDER - CORNEAL TOPOGRAPHIC ASTIGMATISM (CORT)
    Alpins, Noel
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 : 32 - 32
  • [7] ACCURACY OF TOTAL CORNEAL TOPOGRAPHIC ASTIGMATISM (CORT TOTAL) COMPARED TO THE TOTAL CORNEAL POWER MEASURED USING 3 DIFFERENT YOMOGRAPHERS
    Alpins, Noel A. M.
    Randleman, Bradley
    Neyvas-Wallce, Anita
    Ong, James
    Stamatelatos, George
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 : 51 - 51
  • [8] CORNEAL TOPOGRAPHIC ASTIGMATISM (CORT) - A BETTER MEASURE OF CORNEAL ASTIGMATISM THAT CORRESPONDS TO MANIFEST REFRACTIVE CYLINDER
    Alpins, Noel
    Ong, James K. Y.
    Stamatelatos, George
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 : 28 - 28
  • [9] Repeatability and agreement of total corneal astigmatism measured in keratoconic eyes using four current devices
    Feng, Yue
    Nitter, Tore
    Bertelsen, Geir
    Stojanovic, Aleksandar
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024,
  • [10] 5. CORNEAL TOPOGRAPHIC ASTIGMATISM (CORT) - AN ACCURATE MEASURE OF CORNEAL ASTIGMATISM FOR TORIC IOLS AND REFRACTIVE TREATMENTS
    Alpins, Noel
    Stamatelatos, George
    Ong, James
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 44 : 68 - 69