4D display of CT LV endocardial and epicardial models morphed from PET Rb-82 perfusion studies accurately quantifies segmental myocardial thickening

被引:0
|
作者
Piccinelli, Marina [1 ,2 ]
Cooke, C. David [1 ]
Folks, Russell [1 ]
Garcia, Ernest V. [1 ]
机构
[1] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA USA
[2] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, 1364 Clifton Rd,NE, Atlanta, GA 30322 USA
关键词
PET; image analysis; image interpretation; WALL-MOTION; GATED SPECT; CLINICAL VALIDATION;
D O I
10.1007/s12350-023-03269-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundMPI-derived LV wall thickening assessments for diagnostic purposes has been part of clinical guidelines for two decades. It relies on visual evaluation of tomographic slices or regional quantification displayed in 2D polar maps. 4D displays have not entered clinical usage nor have they been validated on their potential to provide equivalent information. The purpose of this work was to validate a 4D realistic display recently designed to quantitatively represent the thickening information from gated MPI into CT-morphed endocardial and epicardial moving surfaces.MethodsForty patients who underwent Rb-82 PET were selected based on LV perfusion quantification. CTA templates of heart anatomy were selected to represent the LV anatomy. Generic CT-derived LV endocardial and epicardial surfaces were modified to represent the end diastolic (ED) phase according to PET-derived ED LV dimensions and wall thickness. These CT myocardial surfaces were then morphed by means of thin plate spline (TPS) techniques, according to the gated PET slices count changes (WThPET) and LV wall motion (WMoPET). A geometric thickening (GeoTh) equivalent to LV WThPET was defined on epicardial and endocardial CT surfaces over the cardiac cycle and the two measures compared. WThPET and GeoTh correlations were performed on a case-by-case basis, by segment and by pooling all 17 segments. Pearson's correlation coefficients (PCC) were calculated to assess the equivalence of the two measures.ResultsTwo cohorts of patients (normal and abnormal) were identified based on SSS. R coefficients were as follows: for all pooled segments PCCstress and PCCrest were respectively 0.91 and 0.89 (normal), and 0.9 and 0.91 (abnormal); when individual 17 segments were considered mean PCCstress = 0.92 [0.81-0.98] and mean PCCrest = 0.93 [0.83-0.98] for the abnormal perfusion group; mean PCCstress = 0.89 [0.78-0.97] and mean PCCrest = 0.89 [0.77-0.97] for the normal. When individual studies were considered, R was always > .70 with the exception of five abnormal studies. Inter-user analysis was also conducted.ConclusionsOur novel technique for the visualization of LV wall thickening by means of 4D CT endocardial and epicardial surface models accurately replicated Rb-82 slice thickening results showing promise for its usage for diagnostic purposes.
引用
收藏
页码:2314 / 2326
页数:13
相关论文
共 11 条
  • [1] 4D display of CT LV endocardial and epicardial models morphed from PET Rb-82 perfusion studies accurately quantifies segmental myocardial thickening
    Marina Piccinelli
    C. David Cooke
    Russell Folks
    Ernest V. Garcia
    Journal of Nuclear Cardiology, 2023, 30 : 2314 - 2326
  • [2] D dynamic display of CT left ventricular endocardial and epicardial surface models morphed from PET Rb-82 perfusion studies accurately assesses segmental myocardial thickening
    Piccinelli, Marina
    Cooke, Charles
    Folks, Russ
    Garcia, Ernest
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63
  • [3] 4D Respiratory Motion-Corrected Rb-82 Myocardial Perfusion PET Image Reconstruction
    Rahmim, Arman
    Tang, Jing
    Ay, M. R.
    Bengel, F. M.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3312 - 3316
  • [4] Prompt-gamma compensation in Rb-82 myocardial perfusion 3D PET/CT
    Esteves, Fabio P.
    Nye, Jonathan A.
    Khan, Akbar
    Folks, Russell D.
    Halkar, Raghuveer K.
    Garcia, Ernest V.
    Schuster, David M.
    Lerakis, Stamatios
    Raggi, Paolo
    Votaw, John R.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (02) : 247 - 253
  • [5] Prompt-gamma compensation in Rb-82 myocardial perfusion 3D PET/CT
    Fabio P. Esteves
    Jonathan A. Nye
    Akbar Khan
    Russell D. Folks
    Raghuveer K. Halkar
    Ernest V. Garcia
    David M. Schuster
    Stamatios Lerakis
    Paolo Raggi
    John R. Votaw
    Journal of Nuclear Cardiology, 2010, 17 : 247 - 253
  • [6] Prompt-gamma compensation in Rb-82 myocardial perfusion 3D PET/CT: Effect on clinical practice
    Valeria M. Moncayo
    Ernest V. Garcia
    Journal of Nuclear Cardiology, 2018, 25 : 606 - 608
  • [7] Prompt-gamma compensation in Rb-82 myocardial perfusion 3D PET/CT: Effect on clinical practice
    Moncayo, Valeria M.
    Garcia, Ernest V.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (02) : 606 - 608
  • [8] Automated quantitative Rb-82 3D PET/CT myocardial perfusion imaging: Normal limits and correlation with invasive coronary angiography
    Ryo Nakazato
    Daniel S. Berman
    Damini Dey
    Ludovic Le Meunier
    Sean W. Hayes
    Jimmy S. Fermin
    Victor Y. Cheng
    Louise E. J. Thomson
    John D. Friedman
    Guido Germano
    Piotr J. Slomka
    Journal of Nuclear Cardiology, 2012, 19 : 265 - 276
  • [9] Automated quantitative Rb-82 3D PET/CT myocardial perfusion imaging: Normal limits and correlation with invasive coronary angiography
    Nakazato, Ryo
    Berman, Daniel S.
    Dey, Damini
    Le Meunier, Ludovic
    Hayes, Sean W.
    Fermin, Jimmy S.
    Cheng, Victor Y.
    Thomson, Louise E. J.
    Friedman, John D.
    Germano, Guido
    Slomka, Piotr J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (02) : 265 - 276
  • [10] Preliminary normal values for left ventricular mechanical synchrony from stress Rb-82 PET myocardial perfusion ECG-gated studies
    Cooke, David
    Esteves, Fabio
    Chen, Ji
    Garcia, Ernest
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50