In-line refractive index measurement: a simple method based on image detection

被引:0
|
作者
Bodo, Elisabetta [1 ,2 ]
Gowda, Hitesh G. B.
Wallrabe, Ulrike [2 ]
Wapler, Matthias C. [3 ]
机构
[1] Univ Pavia, Dept Elect Comp & Biomed Engn, Via Ferrata 5, I-27100 Pavia, Italy
[2] Univ Freiburg, IMTEK Dept Microsyst Engn, Lab Microactuators, Georges Kohler Allee 102, D-79110 Freiburg, Germany
[3] Otto von Guericke Univ, Fac Elect Engn & Informat Technol, Chair Microsyst Med Engn, Magdeburg, Germany
关键词
Università degli Studi di Pavia; Ministero dell’Università e della Ricerca; Deutsche Forschungsgemeinschaft (WA 1657/6-2; WA 4555/2-1). The authors thank the Gisela and Erwin Sick Chair of Micro-Optics for use of the refractometer and Professor Sabina Merlo for fruitful discussions on this research;
D O I
10.1364/AO.493243
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a simple method to determine the refractive index of fluids that is suitable for real-time integrated mea-surements by imaging a collimated beam through a fluid volume and determining its diameter on a CMOS sensor. Our experimental results agree with the prediction of our analytical model, and the resulting refractive index agrees with the measurements obtained with a commercial refractometer with an RMS deviation of just & PLUSMN;0.003. This method requires only inexpensive components: a light source, two lenses, and a camera sensor; it is suitable for real-time monitoring, and it is essentially unlimited in the range of refractive indices. & COPY; 2023 Optica Publishing Group
引用
收藏
页码:6282 / 6286
页数:5
相关论文
共 50 条
  • [1] Simple measurement method of the refractive index of biotissue
    Cheng, Shu-Ying
    Shen, Hong-Yuan
    Zhang, Ge
    Huang, Xiang-Jin
    Huang, Cheng-Hui
    Lin, Wen-Xiong
    Huang, Jian-Hong
    Zhongguo Jiguang/Chinese Journal of Lasers, 2002, 29 (05): : 450 - 454
  • [2] In-line Refractive Index Monitoring for CMP Slurry Fault Detection
    Aparece, Carlo Dominic
    Johnston, Robert
    Kavaljer, Marcus
    2015 INTERNATIONAL CONFERENCE ON PLANARIZATION/CMP TECHNOLOGY (ICPT), 2015,
  • [3] A Method of the Detection of Marine Pollution Based on the Measurement of Refractive Index
    Shi, Qing-guo
    Ying, Lu-na
    Wang, Lu
    Peng, Bao-jIn
    Ying, Chao-fu
    Design, Manufacturing and Mechatronics, 2014, 551 : 347 - 352
  • [4] Refractive index sensor based on tapered PCF in-line interferometer
    Liu, Qi
    Wang, Qin
    CHINESE OPTICS LETTERS, 2012, 10 (09)
  • [5] Refractive index sensor based on tapered PCF in-line interferometer
    刘奇
    王琴
    Chinese Optics Letters, 2012, 10 (09) : 13 - 16
  • [6] Photonic jet reconstruction for particle refractive index measurement by digital in-line holography
    Sentis, Matthias P. L.
    Onofri, Fabrice R. A.
    Lamadie, Fabrice
    OPTICS EXPRESS, 2017, 25 (02): : 867 - 873
  • [7] A novel fiber in-line Michelson interferometer based on end face packaging for temperature and refractive index measurement
    Wang, Jin
    Liu, Bo
    Wu, Yongfeng
    Mao, Yaya
    Zhao, Lilong
    Sun, Tingting
    Nan, Tong
    OPTIK, 2019, 194
  • [8] In-line Fabry-Perot refractive index sensor based on microcavity
    Xu, Feng
    Lu, Lu
    Lu, Weiwei
    Yu, Benli
    CHINESE OPTICS LETTERS, 2013, 11 (08)
  • [9] In-line Fabry-Perot refractive index sensor based on microcavity
    徐峰
    卢璐
    吕卫卫
    俞本立
    Chinese Optics Letters, 2013, 11 (08) : 1 - 4
  • [10] Based on the refractive angle method of complex refractive index measurement
    Zhang, Qiuzhang
    Luo, Tianshu
    OPTIK, 2018, 174 : 692 - 697