Correlation of temperature-sensing microchip and rectal temperature measurements in cats

被引:0
|
作者
Goig, Marta [1 ]
Godino, Javier [2 ]
Tejedor, Maria Teresa [3 ]
Burgio, Federica [2 ]
机构
[1] GCTO MSD Spain, Madrid, Spain
[2] MSD AH Anim Hlth Spain, Madrid, Spain
[3] Univ Zaragoza, Dept Anat Embryol & Anim Genet, CiberCV, Zaragoza, Spain
关键词
cats; microchips; monitoring; temperature; correlation; HOSPITAL VISIT STRESS; BODY-TEMPERATURE; PHYSIOLOGICAL-PARAMETERS; TRANSPONDER THERMOMETRY; INFRARED THERMOMETRY; EXERCISE; VALIDITY; SENSOR;
D O I
10.3389/fvets.2023.1319722
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Introduction: Rectal temperature (RT) is the reference standard for clinical evaluation of body temperature in mammals. However, the use of a rectal thermometer to measure temperature can cause stress and other problems, especially in cats. There is a need for clinical techniques that reduce both stress and defensive behavior as part of the provision of better medical care. Subcutaneous temperature-sensing identification microchips fulfil the current legal requirements and provide a reading of subcutaneous temperature (MT). Methods: The clinical study tried to determine whether there is agreement between MT and RT in normal (n = 58), hospitalized (n = 26) and sedated/anesthetized (n = 36) cats. Three measurements were taken using both methods (MT and RT) in each cat. Correlation between MT and RT, and differences between MT and RT, were estimated for pairs of data-points from the same individual, and all data pairs in each group were considered overall. Results: There was a strong positive correlation between MT and RT (r = 0.7 to 1.0) (p < 0.0005). The mean differences (d) were always negative and although statistically significant, these d values are likely of no biological importance. The overall d was -0.1 degrees C in normal cats (p < 0.0005), -0.1 degrees C in hospitalized cats (p = 0.001) and -0.1 degrees C in sedated/anesthetized cats (p = 0.001). The limits of agreement between MT and RT appear narrow enough for MT to be acceptable estimate of RT. The overall limits of agreement (95%) were -0.71 degrees C and 0.53 degrees C (in normal cats); -0.51 degrees C and 0.34 degrees C (in hospitalized cats) and -0.60 degrees C and 0.42 degrees C (in sedated/anesthetized cats). Discussion: MT may provide a good alternative to RT measurement in cats. However, this study was mostly performed in animals that were normothermic. Therefore, further studies in larger groups of cats under different conditions are needed to compare trends and assess variation with time.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] TEMPERATURE-SENSING ELEMENT
    KRIVONOS.AI
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1968, (01): : 245
  • [2] Temperature-sensing riboceptors
    Anbalagan, Savani
    [J]. RNA BIOLOGY, 2024, 21 (01) : 1 - 6
  • [3] TEMPERATURE-SENSING MATERIALS
    KIMMEL, E
    [J]. CHEMICAL ENGINEERING, 1983, 90 (18) : 135 - &
  • [4] Chemistry - Temperature-sensing trees
    Peplow, M
    [J]. NATURE, 2004, 431 (7008) : 524 - 524
  • [5] Assessing distributed temperature-sensing systems
    不详
    [J]. CONTROL ENGINEERING, 1996, : 93 - 93
  • [6] NEW PORTABLE TEMPERATURE-SENSING DEVICE
    MARCUS, P
    FIELD, D
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1973, 34 (03) : 374 - 376
  • [7] TEMPERATURE MEASUREMENTS IN CATS WITH CHRONICALLY IMPLANTED SENSING DEVICE
    GANFIELD, RA
    SMAHA, LA
    [J]. PHYSIOLOGY & BEHAVIOR, 1971, 7 (06) : 929 - &
  • [8] A Temperature-Sensing Hydrogel Coating on The Medical Catheter
    Li, Yiran
    Li, Dan
    Wang, Jiacheng
    Ye, Tingting
    Li, Qianming
    Li, Luhe
    Gao, Rui
    Wang, Yuanzhen
    Ren, Junye
    Li, Fangyan
    Lu, Jiang
    He, Er
    Jiao, Yiding
    Wang, Lie
    Zhang, Ye
    [J]. ADVANCED FUNCTIONAL MATERIALS, 2024, 34 (10)
  • [9] Insoluble temperature-sensing problem yields innovation
    Houldsworth, J
    [J]. INTECH, 1999, 46 (07) : 63 - 63
  • [10] Temperature-sensing switch avoids mindless chattering
    不详
    [J]. EDN, 2000, 45 (05) : 19 - 19