Accuracy of VO2 estimation according to the widely used Krakau formula for the prediction of cardiac output

被引:0
|
作者
Reiter, Theresa [1 ]
Kerzner, Julia [1 ]
Fette, Georg [2 ,3 ]
Frantz, Stefan [1 ,2 ]
Voelker, Wolfram [1 ]
Ertl, Georg [2 ]
Bauer, Wolfgang [1 ]
Morbach, Caroline [1 ,2 ]
Stoerk, Stefan [1 ,2 ]
Gueder, Guelmisal [1 ,4 ]
机构
[1] Univ Hosp Wurzburg, Dept Internal Med 1, Cardiol Div, Wurzburg, Germany
[2] Univ Hosp Wurzburg, Comprehens Heart Failure Ctr, Dept Clin Res & Epidemiol, Wurzburg, Germany
[3] Univ Wurzburg, Chair Comp Sci 6, Wurzburg, Germany
[4] Univ Hosp Wurzburg, Dept Internal Med 1, Cardiol Div, Oberdurrbacherstr 6, D-97080 Wurzburg, Germany
关键词
Cardiac output; VO2; approximation; Thermodilution; Indirect Fick method; RIGHT HEART CATHETERIZATION; OXYGEN-CONSUMPTION; TRICUSPID REGURGITATION; THERMODILUTION; QUANTIFICATION; ADULTS;
D O I
10.1007/s00059-023-05196-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Invasive cardiac output (CO) is measured with the thermodilution (TD) or the indirect Fickmethod (iFM) in right heart catheterization (RHC). The iFMestimates CO using approximation formulas for oxygen consumption (.VO2), but there are significant discrepancies (> 20%) between both methods. Although regularly applied, the formula proposed by Krakau has not been validated. We compared the CO discrepancies between the Krakau formula with the reference (TD) and three established formulas and investigated whether alterations assessed in cardiac magnetic resonance imaging (CMR) determined the extent of the deviations. Methods: This retrospective study included 188 patients aged 63 +/- 14 years (30% women) receiving both CMR and RHC. The CO was measured with TD or with the iFM using the formulas by Krakau, LaFarge, Dehmer, and Bergstra for. VO2 estimation (iFM-K/-L/-D/-B). Percentage errors were calculated as twice the standard deviation of the difference between two CO methods divided by their means; a cut-off of < 30% was regarded as acceptable. The iFMand TD-derived CO ratio was built, and deviations > 20% were counted. Logistic regression analyses were performed to identify determinants of a deviation of > 20%. Results: The TD-derived CO (5.5 +/- 1.7 L/min) was significantly different from all iFM (K: 4.8 +/- 1.6, L: 4.3 +/- 1.6; D: 4.8 +/- 1.5 L/min; B: 5.4 +/- 1.8 L/min all p< 0.05). The iFMK-CO differed from all methods (p< 0.001) except iFM-D (p= 0.19). Percentage errors between TD-CO and iFM-K/-L/-D/-B were all beyond the acceptance limit (44/45/44/43%), while percentage errors between iFM-K and other iFM were all < 16%. None of the parameters measured in CMR was predictive of a discrepancy of > 20% between both methods. Conclusion: The Krakau formula was comparable to other iFM in estimating CO levels, but none showed satisfactory agreement with the TD method. Improved derivation cohorts for. VO2 estimation are needed that better reflect today's patients undergoing RHC.
引用
收藏
页码:50 / 59
页数:10
相关论文
共 27 条
  • [1] Accuracy of VO2 estimation according to the widely used Krakau formula for the prediction of cardiac output; [Genauigkeit der VO2-Schätzung nach der weitverbreiteten Krakau-Formel zur Prädiktion der kardialen Pumpleistung]
    Reiter T.
    Kerzner J.
    Fette G.
    Frantz S.
    Voelker W.
    Ertl G.
    Bauer W.
    Morbach C.
    Störk S.
    Güder G.
    Herz, 2024, 49 (1) : 50 - 59
  • [2] Prediction of individual cardiac output from measured VO2 and ventilation
    Kang, Min-Yeong
    Hua-Huy, Thong
    Guenther, Sven
    Anh Tuan Dinh-Xuan
    Sapoval, Bernard
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [3] VO2 ESTIMATION EQUATION ACCURACY TO YOUNG ADULTS
    Fortes Garcia, Rafel Chieza
    Melo de Oliveira, Rafael
    Camillo Martinez, Eduardo
    Borba Neves, Eduardo
    ARCHIVOS DE MEDICINA, 2020, 20 (01): : 33 - 39
  • [4] Pedal Frequency Does Not Alter The Cardiac Output : Vo2 Relationship During Cycling
    Lutjemeier, Barbara
    Harms, Craig A.
    Harper, Allison J.
    Ferreira, Leonardo
    Townsend, Dana K.
    Barstow, Thomas J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S313 - S313
  • [5] Influence of age and gender on cardiac output VO2 relationships during submaximal cycle ergometry
    Proctor, DN
    Beck, KC
    Shen, PH
    Eickhoff, TJ
    Halliwill, JR
    Joyner, MJ
    JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (02) : 599 - 605
  • [6] Reliability of peak VO2 and maximal cardiac output assessed using thoracic bioimpedance in children
    Welsman, J
    Bywater, K
    Farr, C
    Welford, D
    Armstrong, N
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2005, 94 (03) : 228 - 234
  • [7] Simultaneous VO2 and cardiac output measurement to estimate oxygen extraction (a-v)O2
    Richard A LaFountain
    Juliet Varghese
    Juliana Serafim da Silveira
    Debbie Scandling
    Orlando P Simonetti
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [8] VO2 AND CARDIAC-OUTPUT DURING REST-EXERCISE AND EXERCISE-EXERCISE TRANSIENTS
    LEYK, D
    HOFFMANN, U
    ESSFELD, D
    BAUM, K
    STEGEMANN, J
    ZEITSCHRIFT FUR KARDIOLOGIE, 1994, 83 : 61 - 65
  • [9] Accuracy of prediction equations to estimate submaximal VO2 during cycle ergometry:: the HERITAGE Family Study
    Stanforth, PR
    Ruthven, MD
    Gagnon, J
    Bouchard, C
    Leon, AS
    Rao, DC
    Skinner, JS
    Wilmore, JH
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1999, 31 (01): : 183 - 188
  • [10] The Six-Minute Step Test as a Predictor of Functional Capacity according to Peak VO2 in Cardiac Patients
    Fonteles Ritt, Luiz Eduardo
    Darze, Eduardo Sahade
    Feitosa, Gustavo Freitas
    Porto, Jessica Santana
    Bastos, Gabriela
    Linhares de Albuquerque, Renata Braga
    Feitosa, Cristiane Miura
    Claro, Thaissa Costa
    Prado, Eloisa Ferreira
    de Oliveira, Queila Borges
    Stein, Ricardo
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2021, 116 (05) : 889 - 895