Measuring body composition in dogs using bioelectrical impedance spectroscopy

被引:0
|
作者
Rae, L. S. [1 ]
Rand, J. S. [2 ]
Ward, L. C. [3 ]
机构
[1] Univ Queensland, Sch Vet Sci, Gatton, Qld 4343, Australia
[2] Australian Pet Welf Fdn, Kenmore, Qld 4069, Australia
[3] Univ Queensland, Sch Chem & Mol Biosci, St Lucia, Qld 4072, Australia
来源
VETERINARY JOURNAL | 2024年 / 304卷
关键词
Dog; Bioelectrical impedance spectroscopy; Body composition; Obesity; DXA; BIOIMPEDANCE; WATER; PREDICTION; VOLUME;
D O I
10.1016/j.tvjl.2024.106067
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Assessment of body composition is an essential aspect of veterinary canine care, particularly as prevalence of overweight and obesity in dogs is increasing. Few quantitative objective methods for body composition measurement are available for routine clinical use. Bioelectrical impedance analysis is widely used in human medicine and nutritional assessment and although it has shown promise in production animals it has not yet been adopted for companion animals. The present study validated bioimpedance spectroscopy (BIS) against the reference method of dual-energy X-ray absorptiometry. Resistivity coefficients for use in BIS were determined: rho e = 444.8 and rho i= 1477.8 ohm.cm and used to predict fat-free mass (FFM) in a cohort of 35 mixed breed dogs. Overall, FFM was predicted to within 3.5% of reference values. At an individual level, FFM was predicted within 2 standard deviations (95% confidence) of 10%. BIS provides an objective quantitative alternative to the widely used semi-quantitative body condition scoring. In addition, BIS provides estimates of body water volumes (total, extra-and intracellular), information that can be useful in fluid management. BIS is inexpensive, and simple to perform but does require brief (<5 min) sedation of the animal.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Bioelectrical impedance spectroscopy and body composition
    Chumlea, WC
    Siervogel, RM
    Wu, YX
    Hall, G
    Guo, SS
    [J]. IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 210 - 213
  • [2] Measuring body composition in dogs using multifrequency bioelectrical impedance analysis and dual energy X-ray absorptiometry
    Rae, L. S.
    Vankan, D. M.
    Rand, J. S.
    Flickinger, E. A.
    Ward, L. C.
    [J]. VETERINARY JOURNAL, 2016, 212 : 65 - 70
  • [3] Accuracy of bioelectrical impedance spectroscopy in measuring changes in body composition during severe weight loss
    Cox-Reijven, PLM
    van Kreel, B
    Soeters, PB
    [J]. JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2002, 26 (02) : 120 - 127
  • [4] Body composition in elite athletes -: validation of bioelectrical impedance spectroscopy
    Slinde, Frode
    Klingberg, Sofia
    Johansson, Hanna
    Zander, Martina
    Hulthen, Lena
    Svantesson, Ulla
    [J]. ANNALS OF NUTRITION AND METABOLISM, 2007, 51 : 291 - 291
  • [5] Development of a Segmental Bioelectrical Impedance Spectroscopy Device for Body Composition Measurement
    Cannon, Thomas
    Choi, JungHun
    [J]. SENSORS, 2019, 19 (22)
  • [6] Use of bioelectrical impedance spectroscopy to provide a measure of body composition in sows
    Muller, T. L.
    Ward, L. C.
    Plush, K. J.
    Pluske, J. R.
    D'Souza, D. N.
    Bryden, W. L.
    van Barneveld, R. J.
    [J]. ANIMAL, 2021, 15 (03)
  • [7] BIOELECTRICAL IMPEDANCE AND BODY-COMPOSITION
    DEVRIES, PMJM
    KOUW, PM
    OLTHOF, CG
    DEVRIES, JPPM
    DONKER, AJM
    [J]. LANCET, 1993, 341 (8844): : 570 - 570
  • [8] BIOELECTRICAL IMPEDANCE AND BODY-COMPOSITION
    WALKER, M
    RODHAM, D
    FULCHER, GR
    CLAYTON, B
    FARRER, M
    ALBERTI, KGMM
    [J]. LANCET, 1993, 341 (8842): : 448 - 448
  • [9] The measurement of body composition by bioelectrical impedance
    Popa, Monica
    Sirbu, Dana
    Curseu, Daniela
    Ionutas, Alina
    [J]. 2006 IEEE-TTTC INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS, VOL 2, PROCEEDINGS, 2006, : 437 - 440
  • [10] BIOELECTRICAL IMPEDANCE AND BODY-COMPOSITION
    不详