Control of Hybrid Active Power Filter to Reduce Harmonics of 3-Phase Cap-Less Inverter

被引:1
|
作者
Lee, Dong-Geun [1 ]
Kim, Rae-Young [1 ]
机构
[1] Hanyang Univ, Dept Elect & Biomed Engn, Seoul, South Korea
关键词
Active power filter; Cap-less; Harmonics; IEC 61000-3-2 Class A; OPTIMAL-DESIGN;
D O I
10.1007/s42835-022-01228-7
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recently, material cost competitiveness in various fields, by applying a cap-less inverter technology that uses a small capacity film capacitor to the dc link, the harmonics of input current increase and the power factor decreases compared to the motor drive inverter that uses the existing large capacitor. The increase in harmonics must be installed by expanding the power facility capacity, and the installation of communication facilities sensitive to harmonics is limited. In addition, the decrease in power factor increases the reactive power component, which requires a large current compared to the actual operating capacity, and causes a problem of reducing the operating range of the product. The hybrid active power filter proposed in this paper reduces high order harmonics by applying L filter to the dc side of a 3 phase cap-less inverter for motor driving. The load harmonic compensation current for overall order harmonics through the active power filter. The input current harmonic is reduced by injecting with the current harmonic by inverting the phase. The IEC 61000-3-2 Class A of international harmonics regulations was met and verified using the proposed harmonic reduction system.
引用
收藏
页码:261 / 270
页数:10
相关论文
共 50 条
  • [1] Control of Hybrid Active Power Filter to Reduce Harmonics of 3-Phase Cap-Less Inverter
    Dong-Geun Lee
    Rae-Young Kim
    Journal of Electrical Engineering & Technology, 2023, 18 : 261 - 270
  • [2] 3-PHASE INVERTER WITH REACTIVE POWER CONTROL
    THORBORG, K
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1973, IA 9 (04) : 473 - 481
  • [3] Novel deadbeat control for 3-level inverter based 3-phase 4-wire active power filter
    Tang, Jian
    Zou, Yunping
    He, Yingjie
    Wang, Chengzhi
    Zhang, Yun
    IECON 2007: 33RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, CONFERENCE PROCEEDINGS, 2007, : 1857 - 1862
  • [4] A new control structure for hybrid power filter to reduce the inverter power rating
    Asiminoaei, Lucian
    Wiechowski, Wojciech
    Blaabjerg, Frede
    Krzeszowiak, Tornasz
    Kedra, Bartosz
    IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 4190 - +
  • [5] Novel Predictive Control of 3-Phase LCL-based Active Power Filter
    Wojciechowski, Daniel
    CPE: 2009 COMPATIBILITY AND POWER ELECTRONICS, 2009, : 298 - 305
  • [6] THE DESIGN AND IMPLEMENTATION OF A 3-PHASE ACTIVE POWER FILTER BASED ON SLIDING MODE CONTROL
    SAETIEO, S
    DEVARAJ, R
    TORREY, DA
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1995, 31 (05) : 993 - 1000
  • [7] POWER ACTIVE-FILTER FOR CONTROLLED 3-PHASE RECTIFIER
    ALEXA, D
    GORAS, T
    ARCHIV FUR ELEKTROTECHNIK, 1991, 75 (01): : 71 - 75
  • [8] Reduction of Harmonics in 3-Phase, 3-Wire System by the Use of Shunt Active Filter
    Kothuru, S.
    Kotturu, J.
    Reddy, Kumar C. H.
    2014 IEEE INTERNATIONAL CONFERENCE ON CIRCUIT, POWER AND COMPUTING TECHNOLOGIES (ICCPCT-2014), 2014, : 7 - 12
  • [9] Active power filter based on NPC inverter for harmonics and reactive power compensation
    Lin, BR
    Yang, KT
    TENCON 2004 - 2004 IEEE REGION 10 CONFERENCE, VOLS A-D, PROCEEDINGS: ANALOG AND DIGITAL TECHNIQUES IN ELECTRICAL ENGINEERING, 2004, : D93 - D96
  • [10] PERFORMANCE COMPARISON OF THE 3-PHASE ACTIVE-POWER-FILTER ALGORITHMS
    JOU, HL
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1995, 142 (06) : 646 - 652