Radiolucent zones of biodegradable magnesium-based screws in children and adolescents-a radiographic analysis

被引:8
|
作者
Delsmann, Maximilian M. [1 ,2 ]
Sturznickel, Julian [1 ,2 ]
Kertai, Michael [3 ]
Stucker, Ralf [1 ,4 ]
Rolvien, Tim [1 ,2 ]
Rupprecht, Martin [1 ,4 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Trauma & Orthopaed Surg, Div Orthopaed, Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Osteol & Biomech, Hamburg, Germany
[3] Univ Med Ctr Regensburg, Dept Pediat Surg, Klin St Hedwig, Regensburg, Germany
[4] Altonaer Kinderkrankenhaus gGmbH, Dept Pediat Orthopaed, Childrens Hosp Hamburg Altona, Bleickenallee 38, D-22763 Hamburg, Germany
关键词
Magnesium screws; Radiolucent zones; Children; Osteosynthesis; Osteotomy; Osteochondral refixation; COMPRESSION SCREWS; FRACTURES; FIXATION; HYDROGEN; IMPLANTS; REMOVAL;
D O I
10.1007/s00402-022-04418-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Albeit the implantation of magnesium-based biodegradable implants can avoid a second surgery for implant removal, the postoperative occurrence of radiolucent zones around these implants based on corrosion processes has not been previously investigated in children and adolescents. We sought to characterize the distinct temporal and spatial dynamics for magnesium-based implants based on standard clinical routine radiographs. Materials and methods We retrospectively analyzed 29 patients, treated with magnesium-based compression screws (MAGNEZIX(R) CS 2.7 mm, CS 3.2 mm, CS(C) 4.8 mm; Syntellix AG) for fracture fixation, osteotomy, or osteochondral refixation. During a follow-up examination, the clinical and functional status was evaluated. Based on digital radiographs, the ratio of the area of the radiolucent zone and that of the screw was evaluated to assess implant degradation at two follow-up visits (i.e., after 6-8 weeks and 12-24 weeks). Results In 29 patients (16/29 females, 14.03 +/- 2.13 years), a total of 57 implants were evaluated that were used for osteotomy (n = 13, screws n = 26), fracture fixation (n = 9, screws n = 18), or osteochondral refixation (n = 7, screws n = 13). All patients healed without complications and regained full function. Radiolucent zones were observed in 27/29 patients at the first follow-up, with significantly decreased ratios at the second follow-up (2.10 +/- 0.55 vs 1.64 +/- 0.60, p = 0.0006). Regression analyses were performed to assess the temporal dynamics of radiolucent zones and revealed significant logarithmic developments for the 2.7 mm and 3.2 mm screws, marked by a strong ratio decrease during the first weeks and an almost complete disappearance after approximately 100 days and 200 days, respectively. In contrast, the ceramic-coated 4.8 mm screws presented a significant linear and slower decrease of radiolucent zones. Conclusion Radiolucent zones are a common phenomenon in the course of implant degradation. However, they represent a self-limiting phenomenon. Remarkably, neither implant failure nor affected implant function is noted in this context. Yet, the microstructural changes accompanying the presence of radiolucent zones remain to be analyzed by three-dimensional high-resolution imaging.
引用
下载
收藏
页码:2297 / 2305
页数:9
相关论文
共 50 条
  • [1] Radiolucent zones of biodegradable magnesium-based screws in children and adolescents—a radiographic analysis
    Maximilian M. Delsmann
    Julian Stürznickel
    Michael Kertai
    Ralf Stücker
    Tim Rolvien
    Martin Rupprecht
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 2297 - 2305
  • [2] Magnesium-based biodegradable implants in children and adolescents
    Stuerznickel, Julian
    Delsmann, Maximilian M.
    Jungesblut, Oliver D.
    Stuecker, Ralf
    Knorr, Christian
    Rolvien, Tim
    Kertai, Michael
    Rupprecht, Martin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (06): : 2382 - 2383
  • [3] Safety and performance of biodegradable magnesium-based implants in children and adolescents
    Stuerznickel, Julian
    Delsmann, Maximilian M.
    Jungesblut, Oliver D.
    Stucker, Ralf
    Knorr, Christian
    Rolvien, Tim
    Kertai, Michael
    Rupprecht, Martin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (08): : 2265 - 2271
  • [4] Safety and performance of biodegradable magnesium-based implants in children and adolescents
    Rehm, Andreas
    Granger, Luke
    Ong, Joshua C. Y.
    Ashby, Elizabeth
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (06): : 2380 - 2381
  • [5] Clinical translation and challenges of biodegradable magnesium-based interference screws in ACL reconstruction
    Luo, Ying
    Zhang, Chao
    Wang, Jue
    Liu, Fangfei
    Chau, Kelvin Wingho
    Qin, Ling
    Wang, Jiali
    BIOACTIVE MATERIALS, 2021, 6 (10) : 3231 - 3243
  • [6] Magnesium-based biodegradable implants
    Sillekens, Wim H.
    EMERGING MATERIALS RESEARCH, 2013, 2 (05) : 216 - 218
  • [7] Biocompatibility and Efficiency of Biodegradable Magnesium-Based Plates and Screws in the Facial Fracture Model of Beagles
    Kim, Byung Jun
    Piao, Yinglan
    Wufuer, Maierdanjiang
    Son, Woo-Chan
    Choi, Tae Hyun
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 76 (05) : 1055.e1 - 1055.e9
  • [8] Overview: Magnesium-Based Biodegradable Implants
    Patrick K. Bowen
    Wim H. Sillekens
    JOM, 2016, 68 : 1175 - 1176
  • [9] Overview: Magnesium-Based Biodegradable Implants
    Bowen, Patrick K.
    Sillekens, Wim H.
    JOM, 2016, 68 (04) : 1175 - 1176
  • [10] Magnesium-based biodegradable microelectrodes for neural recording
    Zhang, Chaoxing
    Wen, Teresa H.
    Razak, Khaleel A.
    Lin, Jiajia
    Xu, Changlu
    Seo, Catherine
    Villafana, Edgar
    Jimenez, Hector
    Liu, Huinan
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 110