Gerbode septal defect after surgery for aortic valve endocarditis

被引:1
|
作者
Castedo, Evaristo [1 ]
Martinez-Cabeza, Palorna [1 ]
Miro, Miguel [2 ]
Riesco, Laura [3 ]
Molina, Luis F. [4 ]
Montero, Maria C. [5 ]
机构
[1] Hosp Univ Torrejon, Serv Cirugia Cardiovasc, Madrid, Spain
[2] Hosp Univ Torrejon, Serv Anestesiol & Reanimac, Madrid, Spain
[3] Hosp Univ Torrejon, Unidad Cuidados Intenst, Madrid, Spain
[4] Hosp Univ Torrejon, Serv Cardiol, Madrid, Spain
[5] Hosp Univ Torrejon, Serv Med Interna, Madrid, Spain
来源
CIRUGIA CARDIOVASCULAR | 2023年 / 30卷 / 01期
关键词
Infective endocarditis; Heart failure; Shunt; Operative procedures;
D O I
10.1016/j.circv.2022.08.002
中图分类号
R61 [外科手术学];
学科分类号
摘要
Gerbode is a rare septal defect that causes a shunt between the left ventricle and the right atrium. We present the case of a 68 -year -old patient with moderate aortic regurgitation under follow-up and a history of recent neurosurgery for resection of a cerebral arteriovenous malformation, with residual epilepsy difficult to control. He was admitted to our center due to fever secondary to thrombophlebitis and positive blood cultures for methicillin-resistant Staphylococcus aureus. Transesophageal echocardiogram showed no signs of endocarditis and targeted antibiotic treatment was started. 6 days later, he presented cardiorespiratory arrest in the context of complete atrioventricular block and low cardiac output. He was admitted to the ICU, where a temporary pacemaker was implanted, suffering a tonic-clonic seizure that required intubation. A new echocardiogram showed massive aortic insufficiency and thickening of the mitro-aortic continuity, so emergent aortic valve replacement was indicated. The patient had a good initial post -surgical evolution but, a week later, a mass in the right atrium associated with a Gerbodetype communication was detected in a control echo. Conservative management was decided, but 15 days after the diagnosis of the shunt, coinciding with a clear clinical worsening, a significant increase in the shunt was observed, and he underwent urgent surgical correction by closing the outlet orifice in the right atrium. Post -surgery control echo showed normally functioning aortic prosthesis, absence of residual shunt and competent tricuspid valve. Postoperative recovery was uneventful and patient was discharge after finishing antibiotic treatment. (c) 2022 Sociedad Espanola de Cirugia Cardiovascular y Endovascular. Published by Elsevier Espana, S.L.U. This is an open access article under the CC BY-NC-ND license (http://creativccommons.org/ licenses/by-nc/4.0)
引用
收藏
页码:38 / 41
页数:4
相关论文
共 50 条
  • [1] Gerbode Defect as a Result of Fungal Aortic Valve Endocarditis
    Pasrija, Chetan
    Mohammed, Isa
    Shats, Irma
    Hong-Zohlman, Susie
    Reoma, Junewai
    Mazzeffi, Michael A.
    Rajagopal, Keshava
    JOURNAL OF HEART VALVE DISEASE, 2015, 24 (03): : 292 - 294
  • [2] Acquired Gerbode type ventricular septal defect after aortic valve replacement
    Yurdakul, Selen
    Tayyareci, Yelda
    Sezgic, Metin
    Aytekin, Saide
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2012, 40 (05): : 471 - 471
  • [3] Acquired ventricular septal defect following surgery for aortic valve endocarditis
    Syed, Labib
    Shipolini, Alex
    Syed, Habib
    Khanji, Mohammed Y.
    BMJ CASE REPORTS, 2020, 13 (06)
  • [4] Transcatheter closure of residual Gerbode defect after aortic valve replacement surgery
    Slim, Mehdi
    Mekki, Nouha
    Ouannes, Sami
    Neffati, Elies
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2022, 6 (07)
  • [5] Acquired Gerbode Defect in a Patient With Infective Endocarditis of Bicuspid Aortic Valve
    Mahdi, Mohammed
    Ozer, Muhammet
    Nagra, Bipinpreet
    Aufiero, Patrick
    Kantharia, Bharat
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (05)
  • [6] Acquired Gerbode Defect After Aortic Valve Replacement
    Pursnani, Amit K.
    Tabaksblat, Martin
    Saric, Muhamed
    Perk, Gila
    Loulmet, Didier
    Kronzon, Itzhak
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (25) : E145 - E145
  • [7] Repair of Gerbode defect and aortic neocuspidization by using bovine pericardium in aortic valve endocarditis
    Sahin, Mehmet Ali
    Yokusoglu, Mehmet
    Kuralay, Erkan
    Ertugrul, Ozal
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 30 (02): : 264 - 266
  • [8] PROSTHETIC AORTIC VALVE ENDOCARDITIS RESULTING IN SEVERE AORTIC INSUFFICIENCY AND ACQUIRED GERBODE DEFECT
    Nelson, Maxine
    Asiedu, Bridget
    Annappah, Dilanthy R.
    Bolyard, Jennifer
    Gopalakrishnan, Prabhakaran
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 4230 - 4230
  • [9] Gerbode defect and left ventricular-aortic discontinuity in prosthetic valve endocarditis
    Tetsuro Uchida
    Azumi Hamasaki
    Yoshinori Kuroda
    Atsushi Yamashita
    Shingo Nakai
    Kimihiro Kobayashi
    Mitsuaki Sadahiro
    Journal of Artificial Organs, 2020, 23 : 288 - 291
  • [10] CASE REPORT OF ACQUIRED GERBODE DEFECT AFTER MECHANICAL AORTIC VALVE REPLACEMENT SURGERY
    Bhattarai, Mukul
    Salih, Mohsin
    Mohammad, Alakchar
    Khan, Muhammad