Design Considerations of an ITO-Coated U-Shaped Fiber Optic LMR Biosensor for the Detection of Antibiotic Ciprofloxacin

被引:9
|
作者
Vikas [1 ]
Saccomandi, Paola [1 ]
机构
[1] Politecn Milan, Dept Mech Engn, I-20156 Milan, Italy
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 03期
关键词
U-shaped fiber; lossy mode resonance; antibiotics; ciprofloxacin; sensitivity; figure of merit; LOSSY MODE RESONANCE; SURFACE-PLASMON RESONANCE; INDIUM-TIN-OXIDE; WASTE-WATER; GAS SENSORS; EXPLOSIVES;
D O I
10.3390/bios13030362
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The extensive use of antibiotics has become a serious concern due to certain deficiencies in wastewater facilities, their resistance to removal, and their toxic effects on the natural environment. Therefore, substantial attention has been given to the detection of antibiotics because of their potential detriment to the ecosystem and human health. In the present study, a novel design of indium tin oxide (ITO) coated U-shaped fiber optic lossy mode resonance (LMR) biosensor is presented for the sensitive detection of the antibiotic ciprofloxacin (CIP). The performance of the designed U-shaped LMR sensor is characterized in terms of its sensitivity, full width at half maximum (FWHM), the figure of merit (FOM), and the limit of detection (LOD). For the proposed U-shaped LMR sensing probe, the various crucial factors such as the thickness (d) of the ITO layer, sensing region length (L), and bending radius (R) are optimized. The thickness of the ITO layer is optimized in such a way that two LMR curves are observed in the transmission spectrum and, thereafter, the performance parameters are evaluated for each LMR. It is observed that the designed U-shaped LMR sensor with optimized parameters shows an approximately seven-fold enhancement in sensitivity compared to the straight-core fiber optic LMR sensor. The numerical results revealed that the designed U-shaped fiber optic LMR biosensor can provide a maximum sensitivity of 17,209.9 nm/RIU with the highest FOM of 91.42 RIU-1, and LOD of 6.3 x 10(-5) RIU for the detection of CIP hydrochloride in the concentration range of 0.001 to 0.029 mol center dot dm(-3). Thus, it is believed that the designed LMR biosensor can practically explore its potential use in environmental monitoring and biomedical applications and hence, opens a new window of opportunity for the researchers working in the field of U-shaped fiber optic LMR biosensing.
引用
收藏
页数:19
相关论文
共 12 条
  • [1] Theoretical Model and Design Considerations of U-Shaped Fiber Optic Sensors: A Review
    Tan, Alfred Jia Yee
    Ng, Sing Muk
    Stoddart, Paul R.
    Chua, Hong Siang
    IEEE SENSORS JOURNAL, 2020, 20 (24) : 14578 - 14589
  • [2] Cu/ITO-Coated Uncladded Fiber-Optic Biosensor Based on Surface Plasmon Resonance
    Wang, Qi
    Sun, Bing
    Hu, Ertao
    Wei, Wei
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2019, 31 (14) : 1159 - 1162
  • [3] Localized Surface Plasmon Resonance-Based Fiber Optic U-Shaped Biosensor for the Detection of Blood Glucose
    Srivastava, Sachin K.
    Arora, Vikas
    Sapra, Sameer
    Gupta, Banshi D.
    PLASMONICS, 2012, 7 (02) : 261 - 268
  • [4] Localized Surface Plasmon Resonance-Based Fiber Optic U-Shaped Biosensor for the Detection of Blood Glucose
    Sachin K. Srivastava
    Vikas Arora
    Sameer Sapra
    Banshi D. Gupta
    Plasmonics, 2012, 7 : 261 - 268
  • [5] U-shaped fiber optic lossy mode resonance sensor for the detection of antibiotics
    Vikas
    Saccomandi, Paola
    2023 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR LIVING ENVIRONMENT, METROLIVENV, 2023, : 50 - 54
  • [6] Fiber-Optic U-Shaped Detection Elements for the Investigation of Photocatalytic Activity of Optical Fibers Coated with Layer of TiO2
    Matejec, Vlastimil
    Mrazek, Jan
    Podrazky, Ondrej
    Hayer, Milos
    Pospisilova, Marie
    SENSOR LETTERS, 2009, 7 (05) : 900 - 904
  • [7] Design and Analysis of a U-Shaped Optical Fiber-Based Plasmonic Sensor for Detection of Cancer Cells
    Mohandas, R.
    Panda, Abinash
    Raja, M. Ramkumar
    Jothi, S. Arul
    PLASMONICS, 2025,
  • [8] Design and Fabrication of Lossy Mode Resonance Based U-Shaped Fiber Optic Refractometer Utilizing Dual Sensing Phenomenon
    Paliwal, Nidhi
    Punjabi, Nirmal
    John, Joseph
    Mukherji, Soumyo
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2016, 34 (17) : 4186 - 4193
  • [9] Ag@Fe3O4-coated U-shaped plastic optical fiber sensor for H2S detection
    Lopez-Vargas, Juan D.
    Dante, Alex
    Allil, Regina C.
    Del Villar, Ignacio
    Matias, Ignacio R.
    Werneck, Marcelo M.
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 401
  • [10] Ultrahigh-sensitivity label-free single mode-tapered multimode-single mode fiber U-shaped biosensor for Staphylococcus aureus detection
    Qiu, Shi
    Leng, Yuankui
    Yuan, Jinhui
    Zhang, Zhichao
    Zhou, Xian
    Liu, Bin
    Mei, Chao
    Yan, Binbin
    Wang, Kuiru
    Sang, Xinzhu
    Long, Keping
    Yu, Chongxiu
    He, Xingdao
    Farrell, Gerald
    Wu, Qiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 375