Fully automated chemiluminescence microarray immunoassay for detection of antinuclear antibodies in systemic autoimmune rheumatic diseases

被引:0
|
作者
Yuan, Dandan [2 ]
Yang, Xue [2 ]
Ji, Chen [3 ]
Sun, Guo [2 ]
Xu, Yang [2 ]
Cao, Ye [2 ]
Ye, Yan [1 ]
Wang, Tingting [1 ]
Hu, Zhigang [2 ]
机构
[1] Nanjing Med Univ, Dept Clin Lab, Wuxi Peoples Hosp, Wuxi, Jiangsu, Peoples R China
[2] Jiangnan Univ, Childrens Hosp, Dept Clin Lab, Wuxi, Jiangsu, Peoples R China
[3] Jiangsu Sunlant Bioengn Co Ltd, Wuxi, Jiangsu, Peoples R China
关键词
antinuclear antibodies; CLMIA; systemic autoimmune rheumatic diseases; LINE IMMUNOASSAY; AUTOANTIBODIES;
D O I
10.1515/labmed-2023-0145
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives Detection of specific antinuclear antibodies is very important in term of diagnosis, prognosis and management of patients with systemic autoimmune rheumatic diseases. Chemiluminescence microarray immunoassay (CLMIA) is a microdot array-based method that allows simultaneous detection of multiple antinuclear antibodies, which received increasing attention. Methods A CLMIA method that can detect 14 kinds of antinuclear antibodies was established and optimized. Basic performance and diagnostic performance of CLMIA was evaluated by comparing it with line immunoassay (LIA) and indirect immunofluorescence (IIF). Results Through conditional exploration, the optimal blocking time and blocking temperature were determined to be 18 h and 25 degrees C, respectively. The enzyme-labeled secondary antibody reaction concentration was 0.1 mu g/mL, the incubation temperature of serum and enzyme-labeled secondary antibody were 30 degrees C, and the incubation time of serum and enzyme-labeled secondary antibody were 40 min. After parameter optimization, CLMIA demonstrated high accuracy with a relative bias <15 %; high sensitivity with detection limits below 3 IU/mL for dsDNA and below 1 RU/mL for other ANAs; and high reproducibility with both intra-assay and inter-assay coefficients of variation (CV) <15 %.The CLMIA detection method established in this study was also demonstrated to have good clinical diagnostic performance, showing the highest area under curve (AUC=0.87, p=0.042 and p=0.03). The CLMIA and LIA revealed substantial to good agreements on specific antinuclear antibodies except anti-dsDNA, with the Cohen's kappa from 0.72 to 0.89. Samples that produced discrepant results between the CLMIA and LIA methods were further analyzed. Upon additional testing, most of these samples were ultimately determined to have been correctly detected by the CLMIA assay rather than the LIA assay, suggesting that CLMIA also shows some superiority in diagnosing dsDNA. Conclusions The CLMIA could become a potential routine method for detecting ANAs with the advantages of good detection performance.
引用
收藏
页码:61 / 69
页数:9
相关论文
共 50 条
  • [1] Evaluation of an automated chemiluminescent immunoassay kit for antinuclear antibodies in autoimmune diseases
    Zafrir, Yaron
    Gilburd, Boris
    Garcia Carrasco, Marina
    Kivity, Shaye
    Sanchez-Castanon, Maria
    Lopez-Hoyos, Marcos
    Mandel, Mathilda
    Szmyrka, Magdalena
    Shoenfeld, Yehuda
    Agmon-Levin, Nancy
    [J]. IMMUNOLOGIC RESEARCH, 2013, 56 (2-3) : 451 - 456
  • [2] Evaluation of an automated chemiluminescent immunoassay kit for antinuclear antibodies in autoimmune diseases
    Yaron Zafrir
    Boris Gilburd
    Marina Garcia Carrasco
    Shaye Kivity
    María Sánchez-Castañón
    Marcos López-Hoyos
    Mathilda Mandel
    Magdalena Szmyrka
    Yehuda Shoenfeld
    Nancy Agmon-Levin
    [J]. Immunologic Research, 2013, 56 : 451 - 456
  • [3] Evaluation of antinuclear antibodies (ANA) detection with a fully automated enzyme immunoassay
    Haliassos, A
    Papasteriadi, C
    Tsirogianni, A
    Farmakis, G
    Siorfane, A
    [J]. CLINICAL CHEMISTRY, 2004, 50 (06) : A52 - A52
  • [4] Comparing the diagnostic efficacy of manual and automated screening assays for the detection of antinuclear antibodies in routine diagnostics of systemic autoimmune rheumatic diseases
    Berkemeier, C.
    Heijnen, I. A. F. M.
    [J]. SWISS MEDICAL WEEKLY, 2018, 148 : 35S - 35S
  • [5] PROFILES OF ANTINUCLEAR ANTIBODIES IN SYSTEMIC RHEUMATIC DISEASES
    NOTMAN, DD
    KURATA, N
    TAN, EM
    [J]. ANNALS OF INTERNAL MEDICINE, 1975, 83 (04) : 464 - 469
  • [6] Comparison of two automated antinuclear antibodies screening for the diagnosis of systemic autoimmune diseases
    Aparicio Hernandez, M. B.
    Martin Martin, A. I.
    Framinan Aparicio, B.
    Gomez-Lechon Quiros, L.
    Hidalgo Calleja, M. C.
    [J]. CLINICA CHIMICA ACTA, 2019, 493 : S87 - S88
  • [7] Detection of Antinuclear Antibodies in Childhood Rheumatic Diseases
    Naz, Samia
    Mushtaq, Asma
    Bari, Attia
    Qayyum, Hafiz Talha
    Maqsood, Amnah
    Masood, Tahir
    [J]. PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2012, 6 (03): : 746 - 748
  • [8] Determination of antinuclear antibodies (ANA) in systemic rheumatic diseases
    Chuprina, S.
    Kozmenko, I.
    [J]. CLINICA CHIMICA ACTA, 2024, 558
  • [9] Clinical significance of antinuclear antibodies in systemic rheumatic diseases
    Hietarinta, M
    Lassila, O
    [J]. ANNALS OF MEDICINE, 1996, 28 (04) : 283 - 291
  • [10] COMPARISON OF DIFERENT METHODOLOGIES FOR THE DETECTION OF AUTO ANTIBODIES IN SYSTEMIC AUTOIMMUNE RHEUMATIC DISEASES
    Barrera, Nancy
    Tafur, Marcela
    [J]. JCR-JOURNAL OF CLINICAL RHEUMATOLOGY, 2019, 25 : S94 - S94