Different Home Blood Pressure Thresholds to Predict Perfect 24-Hour Ambulatory Blood Pressure Control in Treated Hypertension Based on an "All-in-One" Device

被引:12
|
作者
Kario, Kazuomi [1 ,2 ]
Tomitani, Naoko [2 ]
Hoshide, Satoshi [2 ]
Nishizawa, Masafumi [3 ]
Yoshida, Tetsuro [4 ]
Kabutoya, Tomoyuki [2 ]
Fujiwara, Takeshi [2 ]
Mizuno, Hiroyuki [2 ]
Okawara, Yukie [2 ]
Kanegae, Hiroshi [2 ]
HI JAMP Study Grp
机构
[1] Jichi Med Univ, Sch Med, Dept Med, Div Cardiovasc Med, 3311-1 Yakushiji, Shimotsuke, Tochigi 3290498, Japan
[2] Jichi Med Univ, Sch Med, Dept Med, Div Cardiovasc Med, Tochigi, Japan
[3] Minamisanriku Hosp, Miyagi, Japan
[4] Onga Hosp, Onga Nakama Med Assoc, Fukuoka, Japan
关键词
ambulatory blood pressure monitoring; blood pressure; blood pressure monitors; hypertension; masked hypertension; CLINICAL-PRACTICE; ARTERIAL STIFFNESS; EUROPEAN-SOCIETY; WHITE-COAT; J-HOP; MANAGEMENT; ASIA; GUIDELINES; STATEMENT; ADULTS;
D O I
10.1161/HYPERTENSIONAHA.123.21578
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND: Home blood pressure (BP) is an important component of digital strategies for hypertension management. However, no studies have used the same device to investigate 24-hour BP control status in relation to different home BP control thresholds.METHODS: Participants in the general practitioner-based, multicenter HI-JAMP study (Home-Activity Information and Communication Technology-Based Japan Ambulatory Blood Pressure Monitoring Prospective) underwent office BP measurement, then 24-hour ambulatory BP monitoring, then home BP monitoring for 5 days. A validated all-in-one BP monitoring device was used to measure office, home, and ambulatory BP. Baseline data were used to investigate ambulatory BP control status in individuals with well-controlled home BP based on the different guideline thresholds (125/75 mm Hg, 130/80 mm Hg, and 135/85 mm Hg).RESULTS: Data from 2269 patients were analyzed. For individuals with well-controlled home BP <135/85 mm Hg (59.5% of the total population), the prevalence of uncontrolled 24-hour (>= 130/80 mm Hg), daytime (>= 135/85 mm Hg), and nighttime ambulatory BP (>= 120/70 mm Hg) was 19.9%, 18.5%, and 33.6%, respectively. Corresponding prevalence rates in the 42.7% of participants with well-controlled home BP <130/80 mm Hg were 13.4%, 12.9%, and 26.0%, and when well-controlled home BP was strictly defined as <125/75 mm Hg (23.9% of the population), prevalence of rates of uncontrolled 24-hour, daytime, and nighttime ambulatory BP were 7.0%, 9.0%, and 15.3%, respectively.CONCLUSIONS: Home BP control status defined using different thresholds could predict 24-hour ambulatory BP control status in treated hypertension. One-third of individuals still had uncontrolled nocturnal hypertension when home BP was controlled to <135/85 mm Hg, but ambulatory BP was quite well controlled when home BP was <125/75 mm Hg.
引用
收藏
页码:2464 / 2472
页数:9
相关论文
共 50 条
  • [1] Comparison of Optimal Diagnostic Thresholds of Hypertension With Home Blood Pressure Monitoring and 24-Hour Ambulatory Blood Pressure Monitoring
    Park, Jin-Sun
    Rhee, Moo-Yong
    Namgung, June
    Lee, Sung Yun
    Cho, Deok-Kyu
    Choi, Tae-Young
    Kim, Seok Yeon
    Kim, Jang Young
    Park, Sang Min
    Choi, Jae Hyuk
    Lee, Jae Hang
    Kim, Hae-Young
    AMERICAN JOURNAL OF HYPERTENSION, 2017, 30 (12) : 1170 - 1176
  • [2] Blood pressure in office and 24-hour ambulatory blood pressure measurements in patients with treated hypertension
    Stepien-Walek, Alicja
    Kluk, Maciej
    Gorczyca-Michta, Iwona
    Dziubek, Katarzyna
    Salwa, Pawel
    Maroszynska-Dmoch, Ewa
    Wozakowska-Kaplon, Beata
    ARTERIAL HYPERTENSION, 2013, 17 (02): : 184 - 190
  • [3] Home Blood Pressure Measurements Will or Will Not Replace 24-Hour Ambulatory Blood Pressure Measurement
    O'Brien, Eoin
    HYPERTENSION, 2009, 54 (05) : E128 - E128
  • [4] Home Blood Pressure Measurements Will Not Replace 24-Hour Ambulatory Blood Pressure Monitoring
    Verdecchia, Paolo
    Angeli, Fabio
    Mazzotta, Giovanni
    Gentile, Giorgio
    Reboldi, Gianpaolo
    HYPERTENSION, 2009, 54 (02) : 188 - 194
  • [5] Impact of obesity on 24-hour ambulatory blood pressure and hypertension
    Kotsis, V
    Stabouli, S
    Bouldin, M
    Low, A
    Toumanidis, S
    Zakopoulos, N
    HYPERTENSION, 2005, 45 (04) : 602 - 607
  • [6] Can 24-hour ambulatory blood pressure measurement predict the development of hypertension in primigravidae?
    Higgins, JR
    Walshe, JJ
    Halligan, A
    OBrien, E
    Conroy, R
    Darling, MRN
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1997, 104 (03): : 356 - 362
  • [7] Response to Home Blood Pressure Measurements Will Not Replace 24-Hour Ambulatory Blood Pressure Monitoring
    Parati, Gianfranco
    Omboni, Stefano
    Bilo, Grzegorz
    HYPERTENSION, 2009, 54 (02) : 195 - 195
  • [8] Home Blood Pressure Measurements Will or Will Not Replace 24-Hour Ambulatory Blood Pressure Measurement Response
    Verdecchia, Paolo
    Angeli, Fabio
    Mazzotta, Giovanni
    Gentile, Giorgio
    Reboldi, Gianpaolo
    HYPERTENSION, 2009, 54 (05) : E130 - E130
  • [9] 24-hour ambulatory blood pressure monitoring
    Anlauf, M
    Baumgart, P
    Franz, IW
    Krönig, B
    Middeke, M
    Schrader, J
    Schulte, KL
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1998, 123 (47) : 1426 - 1430
  • [10] Correspondence between 24-hour ambulatory, clinic and home blood pressure
    Senra, H
    Bianchi, M
    Nieto, F
    Sandoya, E
    Schettini, C
    HYPERTENSION, 1999, 33 (04) : 1091 - 1091