Nursing Perspectives on the Use of Continuous Glucose Monitoring in the Intensive Care Unit

被引:1
|
作者
Faulds, Eileen R. [1 ,2 ,10 ]
Dungan, Kathleen M. [2 ,3 ]
McNett, Molly [1 ,4 ]
Jones, Laureen [5 ]
Poindexter, Norma [6 ]
Exline, Matthew [7 ]
Pattison, Jillian [8 ]
Pasquel, Francisco J. [9 ]
机构
[1] Ohio State Univ, Coll Nursing, Columbus, OH USA
[2] Ohio State Univ, Wexner Med Ctr, Columbus, OH USA
[3] Ohio State Univ, Dept Internal Med, Div Endocrinol Diabet & Metab, Coll Med, Columbus, OH USA
[4] Ohio State Univ, Helene Fuld Hlth Trust Natl Inst Evidence Based Pr, Implementat Sci, Coll Nursing, Columbus, OH USA
[5] Ohio State Univ, Wexner Med Ctr, Crit Care Nursing, Columbus, OH USA
[6] Grady Hlth Syst, Div Crit Care, Atlanta, GA USA
[7] Ohio State Univ, Med Ctr, Div Crit Care Med, Columbus, OH USA
[8] Ohio Hlth Endocrinol, Columbus, OH USA
[9] Emory Univ, Sch Med, Div Endocrinol, Atlanta, GA USA
[10] Ohio State Univ, Coll Nursing, 560 McCampbell Hall,5 South,1581 Dodd Dr, Columbus, OH 43210 USA
来源
关键词
continuous glucose monitoring (CGM); hospital; critical care; nursing; implementation; training; CRITICALLY-ILL PATIENTS; JUST-IN-TIME; HOSPITALIZED-PATIENTS; GLYCEMIC CONTROL; INFUSION PROTOCOL; INSULIN INFUSION; HYPOGLYCEMIA; IMPLEMENTATION; MANAGEMENT; IMPACT;
D O I
10.1177/19322968231170616
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The COVID-19 pandemic necessitated rapid implementation of continuous glucose monitoring (CGM) in the intensive care unit (ICU). Although rarely reported, perceptions from nursing staff who used the systems are critical for successful implementation and future expanded use of CGM in the inpatient setting. Methods: A 22-item survey focused on CGM use was distributed to ICU nurses at two large academic medical centers in the United States in 2022. Both institutions initiated inpatient CGM in the spring of 2020 using the same CGM+point of care (POC) hybrid protocol. The survey employed a 1- to 5-point Likert scale regarding CGM sensor insertion, accuracy, acceptability, usability, training, and perceptions on workload. Results: Of the 71 surveys completed, 68 (96%) nurses reported they cared for an ICU patient on CGM and 53% reported they had independently performed CGM sensor insertion. The ICU nurses overwhelmingly reported that CGM was accurate, reduced their workload, provided safer patient care, and was preferred over POC glucose testing alone. Interestingly, nearly half of nurses (49%) reported that they considered trend arrows in dosing decisions although trends were not included in the CGM+POC hybrid protocol. Nurses received training through multiple modalities, with the majority (80%) of nurses reporting that CGM training was sufficient and prepared them for its use. Conclusion: These results confirm nursing acceptance and preference for CGM use within a hybrid glucose monitoring protocol in the ICU setting. These data lay a blueprint for successful implementation and training strategies for future widespread use.
引用
收藏
页码:649 / 655
页数:7
相关论文
共 50 条
  • [1] Continuous Glucose Monitoring in the Intensive Care Unit
    Guerrero-Arroyo, Lizda
    Faulds, Eileen
    Perez-Guzman, M. Citlalli
    Davis, Georgia M.
    Dungan, Kathleen
    Pasquel, Francisco J.
    [J]. JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (03): : 667 - 678
  • [2] Glucose Control and Use of Continuous Glucose Monitoring in the Intensive Care Unit: A Critical Review
    De Block, Christophe
    Manuel-y-Keenoy, Begona
    Rogiers, Peter
    Jorens, Philippe
    Van Gaal, Luc
    [J]. CURRENT DIABETES REVIEWS, 2008, 4 (03) : 234 - 244
  • [3] EVALUATION OF CONTINUOUS GLUCOSE MONITORING IN AN INTENSIVE CARE UNIT
    Santamaria, John
    [J]. AUSTRALIAN CRITICAL CARE, 2023, 36 : S1 - S1
  • [4] Continuous glucose monitoring in a medical intensive care unit
    De Block, CEM
    Keenoy, BMY
    Van Gaal, LF
    Rogiers, P
    [J]. DIABETOLOGIA, 2005, 48 : A48 - A49
  • [5] Pros and cons of continuous glucose monitoring in the intensive care unit
    Sun, Ming-Tsung
    Li, I-Cheng
    Lin, Wei-Shiang
    Lin, Gen-Min
    [J]. WORLD JOURNAL OF CLINICAL CASES, 2021, 9 (29) : 8666 - 8670
  • [6] Pros and cons of continuous glucose monitoring in the intensive care unit
    Ming-Tsung Sun
    I-Cheng Li
    Wei-Shiang Lin
    Gen-Min Lin
    [J]. World Journal of Clinical Cases, 2021, (29) : 8666 - 8670
  • [7] The Accuracy of Continuous Glucose Monitoring in the Medical Intensive Care Unit
    Tingsarat, Wannita
    Buranasupkajorn, Patinut
    Khovidhunkit, Weerapan
    Boonchaya-anant, Patchaya
    Laichuthai, Nitchakarn
    [J]. JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (06): : 1550 - 1554
  • [8] Intensive insulin therapy in the intensive care unit: assessment by continuous glucose monitoring
    C De Block
    P Rogiers
    B Manuel y Keenoy
    K Bervoets
    M Smet
    L Van Gaal
    [J]. Critical Care, 9 (Suppl 1):
  • [9] Intensive insulin therapy in the intensive care unit - Assessment by continuous glucose monitoring
    De Block, Christophe
    Manuel-y-Keenoy, Begona
    Van Gaal, Luc
    Rogiers, Peter
    [J]. DIABETES CARE, 2006, 29 (08) : 1750 - 1756
  • [10] Continuous glucose monitoring at the intensive care unit: nursing workload reduction and cost-benefit analysis
    Sechterberger, M. K.
    DeVries, J. H.
    van der Voort, P. H. J.
    [J]. DIABETOLOGIA, 2013, 56 : S31 - S31