RAIL FLAW IMAGING PROTOTYPE BASED ON IMPROVED ULTRASONIC SYNTHETIC APERTURE FOCUS METHOD

被引:1
|
作者
Huang, Chengyang [1 ]
Di Scalea, Francesco Lanza [1 ]
机构
[1] Univ Calif San Diego, Dept Struct Engn, Expt Mech & NDE Lab, La Jolla, CA 92093 USA
关键词
nondestructive testing; ultrasonic imaging; synthetic aperture focus; SAF; phased arrays; rail flaws;
D O I
10.32548/2024.me-04371
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This paper presents an experimental prototype developed for rail flaw imaging. This capability can help obtain quantitative information on detected flaws during manual flaw verification. Ultrasonic synthetic aperture focus (SAF) imaging has advantages over phased-array imaging for both speed and accuracy. The prototype developed is hosted in a portable and battery-powered carry-on size case. The probe is a linear ultrasonic array mounted on a wedge and with a position encoder to build 3D point clouds from 2D beamformed images. The prototype includes several advances over the basic SAF technique, including sparse subarray firing that allows fast imaging speeds (e.g., 25 Hz) without sacrificing image accuracy. Validation results are presented from scans performed on rail sections from the FRA rail defect library, which contains natural transverse defects and artificial end-drilled hole defects. The tests showed good accuracy in defect size and shape, as compared to the available ground truth information, for defects located away from the railhead corners. Additional developments are required to properly cover the head corners, and especially in the case of heavily worn rails.
引用
收藏
页码:51 / 59
页数:9
相关论文
共 50 条
  • [1] Rail Defect Imaging by Improved Ultrasonic Synthetic Aperture Focus Techniques
    Sternini, Simone
    Liang, Albert Y.
    di Scalea, Francesco Lanza
    MATERIALS EVALUATION, 2019, 77 (07) : 931 - 940
  • [2] ULTRASONIC TOMOGRAPHY FOR RAIL FLAW IMAGING
    Phillips, Robert
    di Scalea, Francesco Lanza
    Nucera, Claudio
    Rizzo, Piervincenzo
    Al-Nazer, Leith
    PROCEEDINGS OF THE ASME JOINT RAIL CONFERENCE, 2014, 2014,
  • [3] Borehole imaging method based on ultrasonic synthetic aperture technology
    Wang Jin-chao
    Tao Dong-xin
    Huang Yan-qing
    Wang Chuan-ying
    Han Zeng-qiang
    Hu Sheng
    ROCK AND SOIL MECHANICS, 2019, 40 : 557 - 564
  • [4] Ultrasparse Ultrasonic Synthetic Aperture Focus Imaging by Passive Sensing
    Huang, Chengyang
    Hosseinzadeh, Ali Zare
    Lanza di Scalea, Francesco
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (05) : 518 - 535
  • [5] ULTRASONIC RAIL FLAW IMAGING-SYSTEM
    CECCON, H
    MATERIALS EVALUATION, 1982, 40 (03) : A15 - A15
  • [6] Rail steel flaw inspection based on laser ultrasonic method
    Nan, Gangyang
    Wang, Qiwu
    Zhang, Zhenzhen
    Guo, Rui
    Song, Jiangfeng
    Sun, Jihua
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2017, 46 (01):
  • [7] Synthetic transmit aperture method in medical ultrasonic imaging
    Trots, Ihor
    Nowicki, Andrzej
    Lewandowski, Marcin
    World Academy of Science, Engineering and Technology, 2010, 64 : 294 - 297
  • [8] AN IMPROVED SYNTHETIC APERTURE IMAGING METHOD BASED ON GPU IN MEDICAL ULTRASOUND
    Zhang, Z. H.
    Liu, H. F.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2017, 121 : 8 - 8
  • [9] A fast ultrasonic synthetic aperture imaging method: Application to NDT
    Ylitalo, J
    ULTRASONICS, 1996, 34 (2-5) : 331 - 333
  • [10] Fast ultrasonic synthetic aperture imaging method: application to NDT
    Univ of Oulu, Oulu, Finland
    Ultrasonics, 2-5 (331-333):