The Neutral Voltage Difference Signal as a Means of Investigating Eccentricity and Demagnetization Faults in an AFPM Synchronous Generator

被引:2
|
作者
Barmpatza, Alexandra C. [1 ]
机构
[1] Hellen Mediterranean Univ, Dept Mech Engn, Iraklion 71004, Greece
关键词
demagnetization; eccentricity; fault diagnosis; permanent magnet; synchronous generator; PERMANENT-MAGNET MACHINES; STATIC ECCENTRICITIES; PM MACHINES; DIAGNOSIS;
D O I
10.3390/machines11060647
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article investigates the neutral voltage difference signal, V-NO signal, for fault diagnosis. The aforementioned signal is the signal of the voltage between the common star point of the stator and the common star point of the load. The under-study faults are demagnetization and static eccentricity faults, while the machine in which the faults are investigated is an axial flux permanent magnet (AFPM) synchronous generator, suitable for wind power applications. This study was conducted using a 3D finite element method (3D-FEM), and the machine's FEM model was validated through experiments. This method is one of the most accurate methods for electrical machine computation, allowing for a detailed study of electromagnetic behavior. The components that constitute the V-NO signal were determined using a 3D-FEM software program (Opera 18R2). Subsequently, further analysis was performed using MATLAB R2022b software, and a fast Fourier transform (FFT) was applied to this signal. In all the investigated faulty cases, new harmonics appeared, and the healthy amplitudes of most of the already existing harmonics increased. These findings can be used for fault identification. The analysis revealed that the harmonic frequency of 1.5f(s) was the most dominant in the case of demagnetization, while in the case of static eccentricity, the most dominant harmonic was a frequency equal to the machine's operating frequency, f(s). The novelty of this study is that this signal has not previously been used for fault identification, especially in AFPM synchronous machines. This signal depends on EMF voltage and stator phase currents but is less sinusoidal. Consequently, it can detect faults in cases where the aforementioned signals cannot be used for detection.
引用
收藏
页数:19
相关论文
共 31 条
  • [1] Study of a Combined Demagnetization and Eccentricity Fault in an AFPM Synchronous Generator
    Barmpatza, Alexandra C.
    Kappatou, Joya C.
    ENERGIES, 2020, 13 (21)
  • [2] Detection and Classification of Rotor Demagnetization and Eccentricity Faults for PM Synchronous Motors
    Hong, Jongman
    Hyun, Doosoo
    Kang, Tae-june
    Lee, Sang Bin
    Kral, Christian
    Haumer, Anton
    2011 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2011, : 2512 - 2519
  • [3] Detection and Classification of Rotor Demagnetization and Eccentricity Faults for PM Synchronous Motors
    Hong, Jongman
    Park, Sanguk
    Hyun, Doosoo
    Kang, Tae-june
    Lee, Sang Bin
    Kral, Christian
    Haumer, Anton
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2012, 48 (03) : 923 - 932
  • [4] Demagnetization Faults Detection in an Axial Flux Permanent Magnet Synchronous Generator
    Barmpatza, Alexandra C.
    Kappatou, Joya C.
    2017 IEEE 11TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRICAL MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2017, : 153 - 159
  • [5] Fault Diagnosis in an AFPM Synchronous Generator through Phase EMF Voltage Sum
    Barmpatza, A. C.
    Kappatou, J. C.
    2021 IEEE 13TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRICAL MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2021, : 365 - 371
  • [6] Offline Diagnosis and Classification of Demagnetization and Eccentricity Faults for Permanent Magnet Synchronous Motors Using Search Coils
    Cheng, Yuan
    Huang, Wan
    Du, Bochao
    Cui, Shumei
    2022 25TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2022), 2022,
  • [7] Detection of Demagnetization Faults in Surface-Mounted Permanent Magnet Synchronous Motors by Means of the Zero-Sequence Voltage Component
    Urresty, Julio-Cesar
    Riba, Jordi-Roger
    Delgado, Miguel
    Romeral, Luis
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (01) : 42 - 51
  • [8] Early detection of inter-turn and demagnetization faults of permanent magnet synchronous wind generator
    Liu Y.
    Zhang T.
    Wang X.
    Gao X.
    Xie H.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (10): : 252 - 258
  • [9] Features Analysis of Partial Demagnetization Faults in the 6-phase PM Synchronous Generator with Rectifier Load System
    Wang, Binghui
    Sun, Yuguang
    PROCEEDINGS OF THE 2016 6TH INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS, ENVIRONMENT, BIOTECHNOLOGY AND COMPUTER (MMEBC), 2016, 88 : 1499 - 1505
  • [10] Detecting Eccentricity Fault in Permanent Magnet Synchronous Machines by Means of Zero-Sequence Voltage Component
    Zhan, Haolan
    Wu, Lijian
    Lyu, Zekai
    Du, Yidong
    Duan, Rupeng
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (05) : 6761 - 6774