Investigations on performance of single-phase immersion cooling system

被引:16
|
作者
Shrigondekar, Harshad [1 ]
Lin, Yueh-Cheng [1 ]
Wang, Chi-Chuan [1 ]
机构
[1] Natl Yang Ming Chiao Tung Univ, Dept Mech Engn, EE474, 1001 Univ Rd, Hsinchu 300, Taiwan
关键词
Datacenter; Electronic cooling; Single-phase immersion cooling; Dielectric fluid; Thermal resistance; Bypass; HEAT-TRANSFER; FLOW; MANAGEMENT;
D O I
10.1016/j.ijheatmasstransfer.2023.123961
中图分类号
O414.1 [热力学];
学科分类号
摘要
Cooling of data centers is crucial from the point of view of energy consumption and zero downtime of data centers. The present study examines the heat transfer behavior for a single-phase immersion cooling system for dielectric fluid (FC40) and dielectric oil (PAO-6) in a 1 U server. Thermal resistance and the temperature of the server are considered to study the system's thermal performance at various system parameters. Parameters varied are inlet/outlet configuration, bypass of the fluid (a gap between the heat sink and the fluid tank), imposed suction fans, fin pitch of the heat sink, fluid flowrate, fluid inlet temperature, and heat load. T-type configuration of inlet/outlet outperforms Z-type configuration. The performance of the system is reduced monotonically with the increase in the gap spacing between the heat sink and tank due to the increased bypass of fluid. The suction created downstream of the heat sink by deploying two fans in series improves the performance appreciably. The effect of the fin pitch of the heat sink on the performance of the system is different for both fluids. For PAO-6, the fin pitch of 2.2 mm yields better performance than the dense pitch of 1.2 mm whereas FC-40 shows the opposite trend. Thermal resistance considerably decreases for PAO-6 with an increase in fluid flowrate from 1 to 3 LPM. Thermal resistance decreases whereas the temperature of the server increases when the fluid inlet temperature increases from 15 to 35 degrees C. A similar effect is reported when the heat load is increased from 200 to 600 W. Numerical investigations are also carried out for studying to explain the flow field and temperature distribution in case of bypass of fluid. (c) 2023 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Server performance optimization for single-phase immersion cooling data center
    Li, Xueqiang
    Xu, Zhiming
    Liu, Shengchun
    Zhang, Xinyu
    Sun, Haiwang
    [J]. APPLIED THERMAL ENGINEERING, 2023, 224
  • [2] Thermal Performance of Single-Phase and Two-Phase Immersion Cooling in Data Center
    Liu, Chun-Kai
    Chang, Tan-Yi
    [J]. 2022 17TH INTERNATIONAL MICROSYSTEMS, PACKAGING, ASSEMBLY AND CIRCUITS TECHNOLOGY CONFERENCE (IMPACT), 2022,
  • [3] Study on the operation strategy of the water cooling system in the single-phase immersion cooling data center considering cooling tower performance
    Wang, Chenxu
    Yu, Hang
    Xian, Lei
    Liu, Guoqiu
    Chen, Lei
    Tao, Wen-Quan
    [J]. Energy and Buildings, 2024, 324
  • [4] Design of a single-phase immersion cooling system through experimental and numerical analysis
    Cheng, Chin-Chi
    Chang, Po-Chun
    Li, Hsing-Chieh
    Hsu, Fu-, I
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 160
  • [5] SINGLE-PHASE IMMERSION COOLING STUDY OF A HIGH-DENSITY STORAGE SYSTEM
    Karajgikar, Saket
    Kidger, Jasper
    Shaw, Andrew
    Edmunds, Neil
    Mulay, Veerendra
    [J]. PROCEEDINGS OF ASME 2022 INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, INTERPACK2022, 2022,
  • [6] Thermal performance evaluation of electronic fluorinated liquids for single-phase immersion liquid cooling
    Chen, Xi
    Huang, Yongping
    Xu, Shijie
    Bao, Chujin
    Zhong, Yangfan
    Chen, Yongping
    Zhang, Chengbin
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 220
  • [7] Performance evaluation and optimization of data center servers using single-phase immersion cooling
    Wang, Huijuan
    Yuan, Xuejun
    Zhang, Kun
    Lang, Xujin
    Chen, Hua
    Yu, Huimin
    Li, Shengtao
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 221
  • [8] A multi-objective optimization of a single-phase immersion cooling system at cabinet level
    Liu, Zhan
    Sun, Xinshan
    Ji, Shenrui
    Yuan, Kaifeng
    [J]. ENERGY AND BUILDINGS, 2024, 312
  • [9] Performance analysis of single-phase immersion cooling system of data center using FC-40 dielectric fluid
    Muneeshwaran, M.
    Lin, Yueh-Cheng
    Wang, Chi-Chuan
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2023, 145
  • [10] Evaluating the Reliability of Passive Server Components for Single-Phase Immersion Cooling
    Shah, Jimil M.
    Padmanaban, Keerthivasan
    Singh, Hrishabh
    Asokan, Surya Duraisamy
    Saini, Satyam
    Agonafer, Dereje
    [J]. JOURNAL OF ELECTRONIC PACKAGING, 2022, 144 (02)