Lithography-free interdigitated electrodes by trench-filling patterning on polymer substrate for Alzheimer's disease detection

被引:2
|
作者
Rahman, M. Mahabubur [1 ]
Bhuiyan, Nabil H. [1 ]
Park, Minjun [1 ]
Uddin, M. Jalal [1 ,2 ]
Jin, Gyeong J. [1 ]
Shim, Joon S. [1 ,2 ]
机构
[1] Kwangwoon Univ, Dept Elect Convergence Engn, Bio IT Convergence Lab, Seoul 01897, South Korea
[2] NanoGenesis Inc, 20 Kwangwoon Ro, Seoul 01897, South Korea
来源
关键词
Interdigitated electrode array (IDA); Trench filling; Alzheimer's disease (AD); Electrochemical enzyme-linked immunosor; bent assay (e-ELISA); p-aminophenol (PAP); Amyloid beta42 (Ass42) and amyloid beta; aggregated (Ass Agg.); ON-A-CHIP; ARRAY MICROELECTRODES; FABRICATION;
D O I
10.1016/j.bios.2023.115803
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Microelectrodes have played a crucial role in electrochemistry for the last few decades. However, the conventional lithographic processes, the key players in fabrication, are nonetheless technologically challenging, pricey, and lack reproducibility. In this work has developed a novel and low-cost patterned-replication fabrication technology for interdigitated electrode array (IDA) electrodes on the polymer substrate. Conventional UVlithography has been utilized to fabricate the nickel IDA electrode pattern as a master mold on the stainlesssteel substrate, which was replicated onto the polymer substrate by the hot-emboss technique. Then, gold was deposited on the replicated wafer by electron beam evaporation, and finally adhesive tape lift-off was used to obtain the gold IDA electrode. The fabricated IDA electrode was applied for electrochemical detection of various p-aminophenol (PAP) concentrations as a representative biomarker with a detection limit of 0.01 nM. Finally, different levels of amyloid beta 42 (Ass42) and amyloid beta aggregated (Ass Agg.), two Alzheimer's disease (AD) biomarkers, were measured using the developed IDA electrode via e-ELISA using enzyme by-products PAP. While quantified, the proposed IDA electrode successfully detects Ass42 and Ass Agg. with the lower detection limit (LOD) of 3.9 and 7.81 pg/ml, respectively.
引用
收藏
页数:8
相关论文
共 1 条
  • [1] Screen-Printed Electrodes on Tyvek Substrate as Low-Cost Device to Applications in Alzheimer's Disease Detection
    Palley, Bianca Fortes
    Artur, Julio Cesar
    de Arruda, Milena Nakagawa
    de Souza, Gustavo Freitas
    Graves, David Alexandro
    de Carvalho Bovolato, Ana Livia
    Deffune, Elenice
    Schelp, Arthur Oscar
    Goncalves, Emerson Sarmento
    de Moraes, Marli Leite
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (03)