Inverter open circuit fault diagnosis based on residual performance evaluation

被引:3
|
作者
Sun, Tianyu [1 ]
Chen, Chaobo [1 ,4 ]
Wang, Shenhang [2 ]
Zhang, Binbin [1 ]
Fu, Yanfang [3 ]
Li, Jichao [1 ]
机构
[1] Xian Technol Univ, Sch Elect Informat Engn, Xian, Shaanxi, Peoples R China
[2] Beijing Aerosp Automat Control Inst, Beijing, Peoples R China
[3] Xian Technol Univ, Sch Comp Sci & Engn, Xian, Shaanxi, Peoples R China
[4] Xian Technol Univ, Sch Elect Informat Engn, Xian 710021, Shaanxi, Peoples R China
关键词
DC-AC power convertors; fault diagnosis; invertors; mathematical analysis; power electronics; interval sliding mode observer; inverter; open circuit fault diagnosis; residual performance evaluation; DESIGN;
D O I
10.1049/pel2.12583
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Because of uncertain random noise and unknown disturbance, the observer-based inverter fault diagnosis meets the problems of large deviation of current observation value and high false alarm rate. An inverter open-circuit fault diagnosis method is proposed via residual performance evaluation. Firstly, the interval sliding mode observer is constructed by combining the interval observer with the sliding mode observer. Three phase current estimates are obtained and current residuals are calculated. Secondly, the residual performance indicators are calculated using the evaluation function. The fault detection is derived by comparing residual performance with the threshold. Thirdly, a residual information table is established based on the fault information contained in the residual for fault isolation. Finally, the proposed algorithm is validated on simulation and physical platforms. Compared with traditional observer-based diagnostic methods, the introduction of residual performance evaluation improves the diagnostic speed by more than 50%. The interval sliding mode observer has higher estimation accuracy and anti-interference ability in the presence of noise and external disturbances. This paper proposes an inverter open circuit fault diagnosis method based on residual performance evaluation. The fault detection is derived by comparing residual performance with the threshold. Besides, a current interval sliding mode observer is designed in the residual generation process.image
引用
收藏
页码:2560 / 2576
页数:17
相关论文
共 50 条
  • [1] NPC Type Inverter Open Circuit Fault Diagnosis Method Based on Residual Performance Evaluation
    Chen, Chaobo
    Dai, Jiawei
    Sun, Tianyu
    Zhang, Binbin
    Gao, Song
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (21): : 6877 - 6895
  • [2] Inverter Open Circuit fault diagnosis method based on ISMO for Improved Efficiency
    Han, Sumin
    Zhao, Guoshuai
    Gao, Jingli
    Jia, Jiaoxin
    [J]. COMPUTERS & ELECTRICAL ENGINEERING, 2024, 120
  • [3] Open-Circuit Fault Diagnosis for Three-Level ANPC Inverter Based on Predictive Current Vector Residual
    Li, Guohua
    Xu, Shuai
    Sun, Zhenyao
    Yao, Chunxing
    Ren, Guanzhou
    Ma, Guangtong
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2023, 59 (06) : 6837 - 6851
  • [4] Open circuit fault diagnosis of t-type inverter
    Ma X.
    Li M.
    Wei S.
    Shi H.
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2018, 33 (10): : 2324 - 2333
  • [5] Diagnosis method of open-circuit fault for T-type three-level inverter based on residual voltage
    Chen, Danjiang
    Liu, Yutian
    Zhou, Junwei
    Zhang, Shaozhong
    [J]. JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2020, 20 (04) : 1143 - 1153
  • [6] Open-circuit Fault Diagnosis of Transistor in Inverter Based on Wavelet Neural Network
    Cui Bowen
    [J]. PROCEEDINGS OF THE 29TH CHINESE CONTROL CONFERENCE, 2010, : 4019 - 4023
  • [7] An IGBT output power-based diagnosis of open-circuit fault in inverter
    School of Electrical Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan Province, China
    不详
    [J]. Shang, W. (shangwujun@126.com), 1600, Power System Technology Press (37):
  • [8] Open-circuit fault diagnosis of traction inverter based on compressed sensing theory
    Cheng Y.
    Dong W.
    Gao F.
    Xin G.
    [J]. Chinese Journal of Electrical Engineering, 2020, 6 (01): : 52 - 60
  • [9] A Multiswitch Open-Circuit Fault Diagnosis of Microgrid Inverter Based on Slidable Triangularization Processing
    Huang, Zhanjun
    Wang, Zhanshan
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (01) : 922 - 930
  • [10] A Diagnosis Method of Inverter Open-Circuit Fault Based on Interval Sliding Mode Observer
    Li, Jin
    Zhang, Youmin
    [J]. 2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 604 - 608