Numerical investigation of double layered PCM building envelope during charging cycle for energy saving

被引:6
|
作者
Arfi, Oualid [1 ,2 ]
Mezaache, El Hacene [1 ]
Laouer, Abdelghani [3 ]
机构
[1] Univ Skikda, Lab Res Phys Chem Surfaces & Interfaces, Skikda 21000, Algeria
[2] Res Ctr Semicond Technol Energy, CRTSE 02,Bd Dr Frantz FANON, BP 140-7, Algiers 16038, Algeria
[3] Univ Jijel, Lab Condensed Matter Phys & Nanomat, Jijel 18000, Algeria
关键词
Phase change material; Solidification; Double PCM layer; Cold storage; Solid fraction; Enthalpy method; PHASE-CHANGE MATERIAL; THERMAL MANAGEMENT; STORAGE;
D O I
10.1016/j.icheatmasstransfer.2023.106797
中图分类号
O414.1 [热力学];
学科分类号
摘要
An efficient operating cycle of a building envelope containing PCM layers requires a well charging cycle. The goal of this work is to carry out a detailed study to overcome situations where the PCM double layer building envelope is not efficient. Taking into account numerous combinations of melting temperatures (0m1, 0m2), and latent heat (Ste1, Ste2), the heat lost over charging cycle is examined. The finite volume approach is used to solve numerically the mathematical model that governs the configuration. The obtained results show that the melting temperature of outer PCM layer is the main controlling parameter of the heat lost amount, where increasing 0m1 increases the heat lost, such as, combination (0m1=0.7, 0m2=0.5) releases the ratio of 18% as extra heat more than the reference case (without PCM). While, for the combination (0m1=0.5, 0m2=0.7) it achieves 13%. Moreover, it is better for the latent heat of the inner layer to be lower than the latent heat of the outer layer, which leads to a strong solidification process, then, a high amount of released heat could be achieved. As well as, for combination (Ste1=0.1, Ste2=0.01) the extra heat released ratio was 15%, while for (Ste1=0.1, Ste2=0.5) it was 8%.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Investigation of PCM charging for the energy saving of domestic hot water system
    Gorzin, Majid
    Hosseini, Mohammad J.
    Ranjbar, Ali A.
    Bahrampoury, Rasool
    [J]. APPLIED THERMAL ENGINEERING, 2018, 137 : 659 - 668
  • [2] Experimental and numerical investigation of the cross-flow PCM heat exchanger for the energy saving of building HVAC
    Promoppatum, Patcharapit
    Yao, Shi-Chune
    Hultz, Thomas
    Agee, Dave
    [J]. ENERGY AND BUILDINGS, 2017, 138 : 468 - 478
  • [3] Efficacy of incorporating PCM into the building envelope on the energy saving and AHU power usage in winter
    Abu-Hamdeh, Nidal H.
    Melaibari, Ammar A.
    Alquthami, Thamer S.
    Khoshaim, Ahmed
    Oztop, Hakan F.
    Karimipour, Aliakbar
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 43
  • [4] Energy saving in building with PCM cold storage
    Stritih, Uros
    Butala, Vincenc
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (15) : 1532 - 1544
  • [5] Numerical Investigation of Energy Saving Characteristic in Building Roof Coupled with PCM Using Lattice Boltzmann Method with Economic Analysis
    Shao, Bilin
    Du, Xingxuan
    Ren, Qinlong
    [J]. APPLIED SCIENCES-BASEL, 2018, 8 (10):
  • [7] Usefulness of PCM in building applications focusing on envelope heat exchange - Energy saving considering two scenarios
    Kalbasi, Rasool
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 50
  • [8] Energy saving effect of building envelope in summer
    Hou-hua Wang
    Rui Guo
    Qiu-lian Xiao
    [J]. Journal of Central South University, 2012, 19 : 1370 - 1376
  • [9] Energy saving effect of building envelope in summer
    Wang Hou-hua
    Guo Rui
    Xiao Qiu-lian
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2012, 19 (05): : 1370 - 1376
  • [10] Energy saving effect of building envelope in summer
    王厚华
    郭锐
    肖秋连
    [J]. Journal of Central South University, 2012, 19 (05) : 1370 - 1376