Development of an Impedimetric Aptasensor for Detection of in Undiluted Fluids

被引:1
|
作者
Kumar, Pankaj [1 ,2 ]
Birader, Komal [1 ]
Suman, Pankaj [1 ,2 ]
机构
[1] Natl Inst Anim Biotechnol, Anim Biotechnol Lab, Hyderabad 500032, India
[2] Manipal Acad Higher Educ, Manipal 576104, Karnataka, India
关键词
aptamer; matrix effect; progesterone; SELEX; aptasensor; APTAMERS; ELECTRODE; BIOSENSOR;
D O I
10.1021/acsptsci.2c00185
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A cost-effective, deployable, and quantitative progesterone biosensor is desirable for regular progesterone sensing in biological and environmental samples to safeguard public health. Aptasensors have been shown to be affordable as compared to antibody-based sensors, but so far, none of the progesterone aptamers could detect it in undiluted and unprocessed biological samples. Thus, to select an aptamer suitable for biosensing in unprocessed biological samples, a modified magnetic bead-based approach with counter-selection in milk and serum was performed. G-quadruplex forming progesterone aptamers were preferentially screened through in silico, gold nanoparticle-based adsorption-desorption assay and circular dichroism spectroscopy. GQ5 aptamer showed extended stability and a high progesterone binding affinity (KD 5.29 +/- 2.9 nM) as compared to any other reported progesterone aptamers (P4G11 and P4G13). Under optimized conditions, GQ5 aptamer was coated on the gold electrode to develop an impedimetric aptasensor (limit of detection: 0.53, 0.91, and 1.9 ng/mL in spiked buffer, undiluted milk, and serum, respectively, with the dynamic range of detection from 0.1 to 50 ng/mL in buffer and 0.1 to 30 ng/mL in both milk and serum). The aptasensor exhibited a very high level of kappa value (>0.9) with ELISA to detect progesterone in milk and serum. The aptasensor could be regenerated three times and can be stored for up to 10 days at 4 degrees C. Therefore, GQ5 may be used to develop a portable impedimetric aptasensor for clinical and on-site progesterone sensing in various biological and environmental samples.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 50 条
  • [1] Development of An Impedimetric Aptasensor for the Detection of Staphylococcus aureus
    Reich, Peggy
    Stoltenburg, Regina
    Strehlitz, Beate
    Frense, Dieter
    Beckmann, Dieter
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2017, 18 (11):
  • [2] Sensitive and antifouling impedimetric aptasensor for the determination of thrombin in undiluted serum sample
    Qi, Honglan
    Li Shangguan
    Li, Congcong
    Li, Xiaoxia
    Gao, Qiang
    Zhang, Chengxiao
    BIOSENSORS & BIOELECTRONICS, 2013, 39 (01): : 324 - 328
  • [3] Impedimetric aptasensor for thrombin detection
    Meini, N.
    Farre, C.
    Chaix, C.
    Kherrat, K.
    Dzyadevych, S.
    Jaffrezic-Renault, N.
    EUROSENSORS XXV, 2011, 25
  • [4] Development of an Impedimetric Aptasensor for Label Free Detection of Patulin in Apple Juice
    Khan, Reem
    Ben Aissa, Sondes
    Sherazi, Tauqir A.
    Catanante, Gaelle
    Hayat, Akhtar
    Marty, Jean Louis
    MOLECULES, 2019, 24 (06)
  • [5] Impedimetric aptasensor for tobramycin detection in human serum
    Gonzalez-Fernandez, Eva
    de-los-Santos-Alvarez, Noemi
    Jesus Lobo-Castanon, Maria
    Jose Miranda-Ordieres, Arturo
    Tunon-Blanco, Paulino
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (05): : 2354 - 2360
  • [6] Development of a label-free impedimetric aptasensor for the detection of Acinetobacter baumannii bacteria
    Abedi, Rokhsareh
    Raoof, Jahan Bakhsh
    Mohseni, Mojtaba
    Hashkavayi, Ayemeh Bagheri
    ANALYTICAL BIOCHEMISTRY, 2023, 679
  • [7] Impedimetric DNA Aptasensor for Sensitive Detection of Ochratoxin A in Food
    Castillo, Gabriela
    Lamberti, Ilaria
    Mosiello, Lucia
    Hianik, Tibor
    ELECTROANALYSIS, 2012, 24 (03) : 512 - 520
  • [8] Reusable impedimetric aptasensor
    Radi, AE
    Sánchez, JLA
    Baldrich, E
    O'Sullivan, CK
    ANALYTICAL CHEMISTRY, 2005, 77 (19) : 6320 - 6323
  • [9] Impedimetric nanoparticle aptasensor for selective and label free pesticide detection
    Madianos, Leonidas
    Skotadis, Evangelos
    Tsekenis, George
    Patsiouras, Lampros
    Tsigkourakos, Menelaos
    Tsoukalas, Dimitris
    MICROELECTRONIC ENGINEERING, 2018, 189 : 39 - 45
  • [10] A new label-free impedimetric aptasensor for gluten detection
    Malvano, Francesca
    Albanese, Donatella
    Pilloton, Roberto
    Di Matteo, Marisa
    FOOD CONTROL, 2017, 79 : 200 - 206