Establishment of ultrasound-guided stellate ganglion block in rats

被引:5
|
作者
Lin, Shi-zhu [1 ]
Chen, Lu [1 ]
Tang, Yi-jie [2 ]
Zheng, Cheng-jie [2 ]
Ke, Peng [2 ]
Chen, Meng-nan [2 ]
Wu, Hai-xing [2 ]
Chen, Yu [2 ]
Qiu, Liang-cheng [2 ]
Wu, Xiao-dan [2 ]
Zeng, Kai [1 ]
机构
[1] Fujian Med Univ, Affiliated Hosp 1, Anesthesiol Res Inst, Natl Reg Med Ctr,Dept Anesthesiol, Binhai Campus, Fuzhou, Peoples R China
[2] Fujian Med Univ, Fujian Prov Hosp, Fujian Prov Clin Med Coll, Dept Anesthesiol, Fuzhou, Fujian, Peoples R China
关键词
ultrasound-guided; blind detection; rat model; protocol; stellate ganglion block (SGB); PERIPHERAL-NERVE BLOCKS; RISK;
D O I
10.3389/fnins.2022.1061767
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
BackgroundA novel protocol for accurate stellate ganglion block under ultrasound guidance was designed in rats. This technique raises the success rate of stellate ganglion block and reduces the incidence of brachial plexus and vagus nerve block. MethodsFifty-six Sprague-Dawley were randomly divided into an ultrasound-guided group (n = 28) and a blind technique group (n = 28). The rats in the blind technique group were injected with 1.5% lidocaine mixed with methylene blue after signs of brachial plexus stimulation were elicited. The lateral side of the cephalic brachial vein was located under the first rib, where lidocaine was injected into the rats in the ultrasound-guided group. The up-and-down sequential method of Dixon was used to determine the minimum effective volume for stellate ganglion block in rats. Furthermore, we calculated the required operative duration of the two methods and observed the difference in the lidocaine diffusion range between the two groups. ResultsThe minimum effective volume for stellate ganglion block in the ultrasound-guided group was 0.040 ml, and the 95% CI was 0.026-0.052 ml. In the blind technique group, the minimum effective volume was 0.639 ml, and the 95% CI was 0.490-0.733 ml. Within the 95% CI of the lowest effective volume, the incidence of brachial plexus block as a complication of stellate ganglion block under ultrasound guidance was 10.00%. ConclusionStellate ganglion block under ultrasound guidance is more accurate than blind detection, which the incidence of complications of stellate ganglion block under ultrasound guidance was significantly lower than under blind detection; the rate of methylene blue staining in the vagus nerve was significantly lower under ultrasound guidance.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Novel ultrasound-guided supraclavicular stellate ganglion block
    Perez, Mario Fajardo
    Yamak-Altinpulluk, Ece
    Tafur, Rodrigo Diez
    Salazar-Zamorano, Carlos H.
    Espinosa Morales, Karla
    Oliver-Fornies, Pablo
    Rocha-Romero, Andres
    Urena, Ricardo Aguilar
    Juarez-Lemus, Angel
    Galluccio, Felice
    Abd-Elsayed, Alaa
    PAIN PRACTICE, 2024, 24 (05) : 808 - 814
  • [2] Ultrasound-Guided Stellate Ganglion Block: Safety and Efficacy
    Narouze, Samer
    CURRENT PAIN AND HEADACHE REPORTS, 2014, 18 (06)
  • [3] Ultrasound-Guided Stellate Ganglion Block: Safety and Efficacy
    Samer Narouze
    Current Pain and Headache Reports, 2014, 18
  • [4] A new approach of ultrasound-guided stellate ganglion block
    Shibata, Yasuyuki
    Fujiwara, Yoshihiro
    Komatsu, Toru
    ANESTHESIA AND ANALGESIA, 2007, 105 (02): : 550 - 551
  • [5] Ultrasound-guided stellate ganglion block: A visual teaching method
    Zhang, Liang
    Li, Xiaoyan
    Yao, Jinhui
    Wulan, Nari
    ASIAN JOURNAL OF SURGERY, 2022, 45 (08) : 1596 - 1597
  • [6] Ultrasound-Guided Stellate Ganglion Block What About the Phrenic Nerve?
    Ojeda, Antonio
    Sala-Blanch, Xavier
    Alfonso Moreno, Luis
    Busquets, Carmen
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2013, 38 (02) : 167 - 167
  • [7] Development and Validation of a New Technique for Ultrasound-Guided Stellate Ganglion Block
    Gofeld, Michael
    Bhatia, Anuj
    Abbas, Sherif
    Ganapathy, Sugantha
    Johnson, Marjorie
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2009, 34 (05) : 475 - 479
  • [8] Avoiding intravascular injection during ultrasound-guided stellate ganglion block
    Nix, C. M.
    Harmon, D. C.
    ANAESTHESIA, 2011, 66 (02) : 134 - 135
  • [9] The optimal volume of 0.2% ropivacaine required for an ultrasound-guided stellate ganglion block
    Jung, Gul
    Kim, Bum Soo
    Shin, Kyung-Bae
    Park, Ki-Bum
    Kim, Sae Yeon
    Song, Sun Ok
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2011, 60 (03) : 179 - 184
  • [10] A lateral paracarotid approach for ultrasound-guided stellate ganglion block with a linear probe
    Kim, Hyuckgoo
    Song, Sun Ok
    Jung, Gul
    JOURNAL OF ANESTHESIA, 2017, 31 (03) : 458 - 462