Structural performance of CFRP strengthened SHS beam-column connections subjected to monotonic loading: A numerical simulation

被引:3
|
作者
Tafsirojjaman, T. [1 ]
Miri, Amin [2 ]
Noor-E-Khuda, Sarkar [3 ]
Ahmed, Aziz [4 ]
Islam, A. B. M. Saiful [5 ]
Khan, Mohammad [6 ]
机构
[1] Univ Adelaide, Sch Architecture & Civil Engn, Adelaide, SA 5005, Australia
[2] Queensland Univ Technol, Sch Civil & Environm Engn, Brisbane, Qld 4000, Australia
[3] Cent Queensland Univ, Sch Engn & Technol, Melbourne, Vic 3000, Australia
[4] Univ Wollongong, Sch Civil Min Environm & Architectural Engn, Wollongong, NSW 2522, Australia
[5] Imam Abdulrahman Bin Faisal Univ, Dept Civil & Construct Engn, Dammam 31451, Saudi Arabia
[6] Melbourne Polytech, Sch Engn, Melbourne, Vic 3076, Australia
关键词
SHS beam-column connection; Strengthening; CFRP; FE modelling; Monotonic loading; Parametric study; STEEL FRAME; BEHAVIOR; MEMBERS; JOINTS;
D O I
10.1016/j.istruc.2024.106030
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Square hollow sections (SHS) have been extensively utilised for welded steel beam-column connections in various structural applications. The performance of these connections can degrade over time due to the degradation of material, fatigue and fabrication as well as construction errors, which can lead to failure. Reinforcing i. e., strengthening SHS beam-column connections can play an important role in enhancing the safety of a wide range of new and existing steel structures. The current study reports a detailed parametric study using a recently developed numerical model and investigates the effects of employing carbon fibre-reinforced polymer (CFRP) composite wrap as a strengthening method for SHS beam-column connections under monotonic loading. A finite element (FE) based numerical model, verified against laboratory test results is used in the study. The influence of key parameters such as the thickness of the beam and column section, steel grade, CFRP modulus and strengthening scheme, on the structural performance of the SHS beam-column connections with and without CFRP is investigated. It is identified that the thicknesses of the beam and column section, steel grade and the modulus of elasticity of CFRP have a notable impact on the moment capacity, secant stiffness, energy dissipation and ductility factor of the connection. It is also found that partial strengthening by wrapping the beam region on three sides with CFRP sheets can increase their moment capacity by 41% compared to the bare connection. The full strengthening of the connection with CFRP recorded a higher increase in the moment capacity of 43%.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Structural behaviour of CFRP strengthened beam-column connections under monotonic and cyclic loading
    Tafsirojjaman, T.
    Fawzia, Sabrina
    Thambiratnam, David P.
    STRUCTURES, 2021, 33 : 2689 - 2699
  • [2] Numerical Simulation of Steel Bolted Beam-column Connections Subjected to Dynamic Loading
    Chang, Liu
    Hai, Tan Kang
    Ching, Fung Tat
    Tyas, Andrew
    PERFORMANCE, PROTECTION AND STRENGTHENING OF STRUCTURES UNDER EXTREME LOADING, 2011, 82 : 314 - +
  • [3] Performance of CFRP strengthened full-scale SHS connections subjected to cyclic loading
    Tafsirojjaman, T.
    Thambiratnam, David P.
    Sulong, N. H. Ramli
    Fawzia, Sabrina
    THIN-WALLED STRUCTURES, 2022, 175
  • [4] Performance of beam-column joints strengthened by CFRP
    College of Urban Construction and Environmental Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
    Shanghai Ligong Daxue Xuebao, 2007, 6 (587-591):
  • [5] FRP strengthened SHS beam-column connection under monotonic and large-deformation cyclic loading
    Tafsirojjaman, T.
    Fawzia, Sabrina
    Thambiratnam, David P.
    Zhao, Xiao-Ling
    THIN-WALLED STRUCTURES, 2021, 161
  • [6] Finite element development of a Beam-column connection with CFRP sheets subjected to monotonic and cyclic loading
    Rahimipour, Arash
    Hejazi, Farzad
    Vaghei, Ramin
    Jaafar, Mohd Saleh
    Computers and Concrete, 2016, 18 (06): : 1083 - 1096
  • [7] Analytical assessment and modeling of RC beam-column connections strengthened with CFRP composites
    Le-Trung, Kien
    Lee, Kihak
    Shin, Myoungsu
    Lee, Jaehong
    COMPOSITES PART B-ENGINEERING, 2011, 42 (07) : 1786 - 1798
  • [8] MONOTONIC AND CYCLIC LOADING SIMULATION OF STRUCTURAL STEELWORK BEAM TO COLUMN BOLTED CONNECTIONS WITH CASTELLATED BEAM
    Vahid, Saeid Zahedi
    Osman, S. A.
    Khalim, A. R.
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2013, 8 (04) : 416 - 427
  • [9] Numerical and Experimental Study on Welded and Bolted Steel Beam-Column Connections Subjected to Cyclic Loading
    Shin, Jinwon
    Kim, Jinkyu
    JOURNAL OF EARTHQUAKE AND TSUNAMI, 2017, 11 (04)
  • [10] A numerical model for simulation of RC beam-column connections
    Omidi, Morteza
    Behnamfar, Farhad
    ENGINEERING STRUCTURES, 2015, 88 : 51 - 73