Data window selection for removal of decaying DC component in current phasor estimation for distance protection

被引:0
|
作者
Hajimahani, Mohammad Kazem [1 ]
Zamani, Hamid [1 ]
Jamali, Sadegh [1 ]
机构
[1] Iran Univ Sci & Technol, Sch Elect Engn, Ctr Excellence Power Syst Automat & Operat, Tehran, Iran
关键词
Distance protection; Decaying DC current; Transmission line; Data window; OFFSET; ALGORITHM; ACCURATE; SIGNAL;
D O I
10.1016/j.epsr.2023.109546
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In distance protection, the fault current signal is usually distorted by the decaying direct current (DC) and harmonics preventing accurate and fast estimation of the fault current phasor. This paper presents a method based on the carefully selected data windows and least square (LSQ) method to improve the performance of the current phasor estimation. The method comprises a short and variable data window for fast operation of distance relay for close faults and a fixed data window for the accurate operation of the relay for faults close to the boundary of Zone 1. The short and variable data window can achieve high speed in the phasor estimation in a quarter of cycle, whereas the second algorithm uses a fixed data window with an excellent frequency response to increase the accuracy of the phasor estimation. The proposed method is first tested using mathematical formulation under different conditions such as different characteristics of the DC component, noise, harmonics and frequency deviation. Then the method is tested by more realistic samples taken from a simulated transmission system under different fault conditions for flexibility, speed and accuracy. All the test results validate the aforementioned features of the proposed algorithms.
引用
下载
收藏
页数:12
相关论文
共 50 条
  • [1] Removal of Decaying DC Offset in Current Signals for Power System Phasor Estimation
    Eisa, Amir A. A.
    Ramar, K.
    2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 190 - 193
  • [2] A Phasor Estimation Algorithm Robust to Decaying DC Component
    Yu, Haotian
    Jin, Zongshuai
    Zhang, Hengxu
    Terzija, Vladimir
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (02) : 860 - 870
  • [3] An analytic method for removal of decaying DC component from phasor estimates
    Niaki, S. H. Ashrafi, 1600, Iranian Research Institute for Electrical Engineering, P.O. Box 16765-1899, Tehran, Iran (12): : 1 - 2
  • [4] Least error squared phasor estimation with identification of a decaying DC component
    Hwang, Jin Kwon
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (07) : 1486 - 1492
  • [5] Fault Current Phasor Estimation Below One Cycle Using Fourier Analysis of Decaying DC Component
    Hwang, Jin Kwon
    Lee, Chang Su
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (05) : 3657 - 3668
  • [6] Removal of the decaying DC effects in distance protection by simultaneously considering the voltage and current waveforms
    Chi-Shan Yu
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2007, 30 (06) : 1047 - 1057
  • [7] Decaying DC Offset Current Mitigation in Phasor Estimation Applications: A Review
    Mohammadi, Sina
    Mahmoudi, Amin
    Kahourzade, Solmaz
    Yazdani, Amirmehdi
    Shafiullah, Gm
    ENERGIES, 2022, 15 (14)
  • [8] A technique for improving performance of phasor estimation algorithms in presence of decaying DC component
    Sidhu, TS
    Zhang, XD
    Albasri, F
    Sachdev, MS
    IPEC 2003: Proceedings of the 6th International Power Engineering Conference, Vols 1 and 2, 2003, : 515 - 520
  • [9] A Novel Technique to Eliminate the Effect of Decaying DC Component on DFT Based Phasor Estimation
    ElRefaie, Hesham B.
    Megahed, A. I.
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [10] A new current estimation algorithm to filter decaying DC component
    Zhang, Xiao-Ming
    Fei, Yu-Sheng
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (20): : 90 - 95