Mechanistic assessment and ablation of left ventricular assist device related ventricular tachycardia in patients with severe heart failure

被引:0
|
作者
Hohendanner, Felix [1 ,2 ,3 ,4 ,5 ]
Bock, Matthias [2 ,3 ,4 ]
Keznickl-Pulst, Julian [6 ]
Furundzija, Vesna [1 ,2 ,3 ,4 ]
Scholz, Sebastian [6 ]
Schoeppenthau, Doreen [1 ,2 ,3 ,4 ]
Hrytsyna, Yuriy [2 ,3 ,4 ,7 ]
Falk, Volkmar [2 ,3 ,4 ,5 ,7 ,8 ]
Pieske, Burkert [6 ]
Hindricks, Gerhard [1 ,2 ,3 ,4 ]
Potapov, Evgenij [2 ,3 ,4 ,5 ]
Gerds-Li, Jin-Hong [1 ,2 ,3 ,4 ]
机构
[1] Klin Kardiol Angiol & Intensivmed, Deutsch Herzzentrum Charite, Berlin, Germany
[2] Charite Univ Med Berlin, Berlin, Germany
[3] Free Univ Berlin, Berlin, Germany
[4] Humboldt Univ, Berlin, Germany
[5] German Ctr Cardiovasc Res DZHK, Partner Site Berlin, Berlin, Germany
[6] German Heart Ctr Berlin, Dept Cardiol, Berlin, Germany
[7] Klin Herz Thorax & Gefasschirurg, Deutsch Herzzentrum Charite, Berlin, Germany
[8] Swiss Fed Inst Technol, Inst Translat Med, Dept Hlth Sci & Technol, Translat Cardiovasc Technol, Berlin, Germany
关键词
ventricular tachycardia; LVAD; RF ablation; heart failure; bench to bedside; CATHETER ABLATION; THICKNESS;
D O I
10.3389/fphys.2023.1086730
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Aims: Left-ventricular-assist-devices (lvad) are an established treatment for patients with severe heart failure with reduced ejection fraction (HF) and reduce mortality. However, HF patients have significant substrate for ventricular tachycardia (VT) and the lvad itself might be pro-arrhythmogenic. We investigated the mechanism of VT in lvad-patients in relation to the underlying etiology and provide in silico and ex-vivo data for ablation in these HF patients.Methods and Results: We retrospectively analyzed invasive electrophysiological (EP) studies of 17 patients with VT and lvad. The mechanism of VT was determined using electroanatomical, entrainment and activation time mapping. Ischemic cardiomyopathy was present in 70% of patients. VT originated from the lvad region in >30%. 1/6 patients with VT originating from the lvad region had episodes before lvad implantation, while 7/11 patients with VT originating from other regions had episodes before implantation. Number and time of radiofrequency (RF)-ablation lesions were not different between VTs originating from the lvad or other regions. Long-term freedom from VT was 50% upon ablation in patients with VT originating from the lvad region and 64% if ablation was conducted in other regions. To potentially preemptively mitigate lvad related VT in patients undergoing lvad implantation, we obtained in silico derived data and performed ex-vivo experiments targeting ventricular myocardium. Of the tested settings, application of 25 W for 30 s was safe and associated with optimal lesion characteristics.Conclusion: A significant percentage of patients with lvad undergoing VT ablation exhibit arrhythmia originating in close vicinity to the device and recurrence rates are high. Based on in silico and ex-vivo data, we propose individualized RF-ablation in selected patients at risk for/with lvad related VT.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [1] Ventricular tachycardia mechanisms and prevention in patients with severe heart failure and left ventricular assist device
    Hohendanner, F.
    Bock, M.
    Keznickl, J.
    Scholz, S.
    Potapov, E.
    Pieske, B.
    Gerds-Li, J. H.
    EUROPEAN HEART JOURNAL, 2022, 43 : 694 - 694
  • [2] Ablation of ventricular tachycardia in a patient with a left ventricular assist device
    Simsek, Evrim
    Ozcan, Emin Evren
    Demir, Emre
    Ozturk, Pelin
    Nalbantgil, Sanem
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2020, 48 (01): : 58 - 63
  • [3] Intraoperative Ventricular Tachycardia Ablation During Left Ventricular Assist Device Implantation in High-Risk Heart Failure Patients
    Tankut, Sinan
    Gosev, Igor
    Yoruk, Ayhan
    Younis, Arwa
    McNitt, Scott
    Bjelic, Milica
    Vidula, Himabindu
    Wu, Isaac
    Aktas, Mehmet K.
    Goldenberg, Ilan
    Huang, David T.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2022, 15 (06):
  • [4] Positional ventricular tachycardia in left ventricular assist device: a new frontier in ventricular tachycardia ablation
    Acou, Willem-Jan M. F.
    Bertagnolli, Livio
    Hindricks, Gerhard
    Arya, Arash
    EUROPEAN HEART JOURNAL, 2014, 35 (02) : 65 - 65
  • [5] Intraoperative Ventricular Tachycardia Ablation During Left Ventricular Assist Device Implant in Patients With Medically Refractory Ventricular Tachycardia
    Yoruk, Ayhan
    Huang, David T.
    Hall, Burr W.
    Rosero, Spencer
    Sherazi, Saadia
    Chen, Leway
    Kutyifa, Valentina
    Massey, H. Todd
    Aktas, Mehmet K.
    CIRCULATION, 2016, 134
  • [6] Left Ventricular Assist Device Implantation in Heart Failure Patients With a Left Ventricular Thrombus
    Engin, C.
    Yagdi, T.
    Balcioglu, O.
    Erkul, S.
    Baysal, B.
    Oguz, E.
    Ayik, F.
    Ozturk, P.
    Ozbaran, M.
    TRANSPLANTATION PROCEEDINGS, 2013, 45 (03) : 1017 - 1019
  • [7] How to perform ventricular tachycardia ablation with a percutaneous left ventricular assist device
    Miller, Marc A.
    Dukkipati, Srinivas R.
    Koruth, Jacob S.
    d'Avila, Andre
    Reddy, Vivek Y.
    HEART RHYTHM, 2012, 9 (07) : 1168 - 1176
  • [8] Left ventricular assist device in heart failure
    Ashraf, O
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (05): : 1211 - 1212
  • [9] Comprehensive cardiac rehabilitation in severe heart failure patients with left ventricular assist device
    Makita, S.
    PROCEEDINGS OF THE 7TH WORLD CONGRESS OF INTERNATIONAL SOCIETY OF PHYSICAL AND REHABILITATION MEDICINE, 2013, : 48 - 49
  • [10] Assessment and Management of Right Ventricular Failure in Left Ventricular Assist Device Patients
    Holman, William L.
    Acharya, Deepak
    Siric, Franjo
    Loyaga-Rendon, Renzo Y.
    CIRCULATION JOURNAL, 2015, 79 (03) : 478 - +